| Owner | Filings | Most Recent |
|---|---|---|
| Firerush | 69 | 07/08/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| Banji Awosika Architect | 8 | 10/10/2025 |
| Concord Associates | 10 | 03/25/2025 |
| Leonid Krupnik, P.E | 4 | 12/26/2023 |
| Enthink Engineers | 1 | 09/30/2023 |
| Stroh Engineering Services | 2 | 09/27/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| Banji Architect | 16 | 03/21/2026 |
| Project Factory NYC | 16 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| Level 10 Construction GR* | General Contractor | 13 | 07/08/2026 |
| Home Improvement MR | General Contractor | 6 | 07/08/2026 |
| Level 10 Construction GR* | Scaffold | 1 | 07/08/2026 |
| Professional Line | Scaffold | 1 | 07/08/2026 |
| Doug's Plumbing & Heating Service Co | Fire Protection | 1 | 07/08/2026 |
| Plumbing-It Mechanical | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| IP Concrete Testing and I | 6252 | 22 | 10/10/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | Home Improvement MR | 02/04/2025 |
| DOB NOW | Mechanical Systems | Signed-off | Home Improvement MR | 11/26/2024 |
| DOB NOW | Curb Cut | Signed-off | Home Improvement MR | 11/25/2024 |
| DOB NOW | Sprinklers | Signed-off | Doug's Plumbing & Heating Service Co | 09/10/2024 |
| DOB NOW | Mechanical Systems | Signed-off | Home Improvement MR | 09/06/2024 |
| DOB NOW | Plumbing | Signed-off | JVR Plumbing and Heating | 06/11/2024 |
| DOB NOW | Foundation | Signed-off | Level 10 Construction | 03/19/2024 |
| DOB NOW | General Construction | Permit Issued | Level 10 Construction | 01/16/2024 |
| DOB NOW | Support of Excavation | Signed-off | Level 10 Construction | 12/22/2023 |
| DOB NOW | General Construction | Permit Issued | Level 10 Construction | 12/21/2023 |
| DOB NOW | Foundation | Signed-off | Level 10 Construction | 12/21/2023 |
| DOB NOW | Structural | Signed-off | Level 10 Construction | 12/07/2023 |
| DOB NOW | Full Demolition | Signed-off | Level 10 Construction | 10/18/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | Professional Line | 10/02/2023 |
| DOB NOW | Construction Fence | Signed-off | Level 10 Construction | 09/29/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/10/2025 | Permit Issued | Home Improvement MR | Heating and Air Conditioning Systems, Others | Heat / Cool Mitsubishi Electric MXZ-SM36NA 78,000 BTU · Vrf Outdoor ×7 Fujitsu AOU36RGLX 77,000 BTU · Split System ×8 ARU18RGLX 38,000 BTU · Ahu ×8 ARU36RGLX 76,000 BTU · Ahu ×8 AOU36RLXFZH 77,000 BTU · Split System ×4 TS18MUERA 38,000 BTU · Ahu ×4 AOUH12LPAS1 29,000 BTU · Split System ×2 AOUH18LPAS1 29,000 BTU · Split System ×2 Other Mitsubishi Electric MLZ-KP09NA 21,000 BTU · Fan Coil Indoor ×15 MLZ-KP12NA 27,000 BTU · Vrf Indoor ×11 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/10/2025 | Signed-off | Doug's Plumbing & Heating Service Co | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/10/2025 | Signed-off | Plumbing-It Mechanical | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/08/2024 | Complete | B.P. Electric | General Wiring |
| 09/30/2023 | Complete | Richard Neu | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/10/2025 | Permit Issued | Home Improvement MR | Masonry |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/10/2025 | Permit Issued | Home Improvement MR | Earthwork |
| Date | Type | Result | Report |
|---|---|---|---|
| 03/28/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 03/20/2025 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 03/12/2025 | Fail-Final Curb Cut Non-Directive 14 | Fail | View ↗ |
| 02/06/2025 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 02/04/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 07/29/2024 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 07/29/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 07/29/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 07/29/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 06/28/2024 | Fail-Final PL - Underground | Fail | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 10/10/2025 | Concrete - Cast-In-Place | INDARDEO PARBHUNATH | special |
| 10/10/2025 | Fire-Resistant Penetrations and Joints | INDARDEO PARBHUNATH | special |
| 10/10/2025 | Masonry | INDARDEO PARBHUNATH | special |
| 10/10/2025 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | INDARDEO PARBHUNATH | special |
| 10/10/2025 | Subgrade Inspections | INDARDEO PARBHUNATH | special |
| 10/10/2025 | Energy Code Compliance Inspections | INDARDEO PARBHUNATH | progress |
| 10/10/2025 | Insulation placement and R values | INDARDEO PARBHUNATH | energy_progress |
| 10/10/2025 | Fenestration and door U-factor and product ratings | INDARDEO PARBHUNATH | energy_progress |
| 10/10/2025 | Fire-Resistance Rated Construction | INDARDEO PARBHUNATH | progress |
| 10/10/2025 | Fenestration air leakage | INDARDEO PARBHUNATH | energy_progress |
| 10/10/2025 | Permanent certificate | INDARDEO PARBHUNATH | energy_progress |
| 10/10/2025 | Exterior lighting power | INDARDEO PARBHUNATH | energy_progress |
| 10/10/2025 | Interior lighting power | INDARDEO PARBHUNATH | energy_progress |
| 10/10/2025 | Electric vehicle service equipment requirements | INDARDEO PARBHUNATH | energy_progress |
| 10/10/2025 | Lighting controls | INDARDEO PARBHUNATH | energy_progress |
| 10/10/2025 | Air barrier — testing | INDARDEO PARBHUNATH | energy_progress |
| 10/10/2025 | Air barrier - visual inspection | INDARDEO PARBHUNATH | energy_progress |
| 10/10/2025 | Lighting in dwelling units | INDARDEO PARBHUNATH | energy_progress |
| 10/10/2025 | Fenestration areas | INDARDEO PARBHUNATH | energy_progress |
| 09/22/2025 | Energy Code Compliance Inspections | INDARDEO PARBHUNATH | progress |
| 09/22/2025 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | INDARDEO PARBHUNATH | special |
| 09/22/2025 | Masonry | INDARDEO PARBHUNATH | special |
| 09/22/2025 | Fire-Resistant Penetrations and Joints | INDARDEO PARBHUNATH | special |
| 09/22/2025 | Concrete - Cast-In-Place | INDARDEO PARBHUNATH | special |
| 09/22/2025 | Fenestration air leakage | INDARDEO PARBHUNATH | energy_progress |