| Owner | Filings | Most Recent |
|---|---|---|
| STY | 27 | 07/08/2026 |
| 1629 BROOKLYN AVENUE LLC | 2 | 03/22/2026 |
| S U MANAGEMENT | 1 | 03/22/2026 |
| STY MANAGEMENT | 1 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 02/24/2022 | $1.7M | — | Private party → 1629 BROOKLYN AVENUE LLC | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| DJLU ARCHITECT | 10 | 12/12/2023 |
| FL&M ENGINEERING DESIGN &INSPECTION | 1 | 01/23/2023 |
| REVAP CONSULTING ENGINEERS LLC | 1 | 04/26/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| EXPEDITING 4 U | 10 | 03/21/2026 |
| GREEN STUDIO | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| S & U MANAGEMENT INC | General Contractor | 15 | 07/08/2026 |
| MANHATTAN D ENTERPRISES | General Contractor | 6 | 03/21/2026 |
| BRUCHE MECHANICAL NY LLC | Fire Protection | 2 | 07/08/2026 |
| DESIGN N SAFETY INC | General Contractor | 2 | 03/21/2026 |
| PLBG P & H INC | Plumbing | 2 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| HRF SERVICES CORP | 5616 | 8 | 12/12/2023 |
| REGIONAL TESTING CORP. | 394 | 1 | 04/07/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | S & U MANAGEMENT INC | 06/07/2023 |
| DOB NOW | Curb Cut | Signed-off | S & U MANAGEMENT INC | 03/14/2023 |
| DOB NOW | Mechanical Systems | Signed-off | S & U MANAGEMENT INC | 03/14/2023 |
| DOB NOW | Sprinklers | Signed-off | BRUCHE MECHANICAL NY LLC | 03/02/2023 |
| DOB NOW | Plumbing | Signed-off | PLBG P & H INC | 03/02/2023 |
| DOB NOW | General Construction | Permit Issued | S & U MANAGEMENT INC | 01/26/2023 |
| DOB NOW | Structural | Signed-off | S & U MANAGEMENT INC | 01/26/2023 |
| DOB NOW | Supported Scaffold | Signed-off | MANHATTAN D ENTERPRISES | 01/23/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | MANHATTAN D ENTERPRISES | 01/23/2023 |
| DOB NOW | Construction Fence | Signed-off | S & U MANAGEMENT INC | 01/19/2023 |
| DOB NOW | Sprinklers | Signed-off | BRUCHE MECHANICAL NY LLC | 01/19/2023 |
| DOB NOW | Plumbing | Signed-off | PLBG P & H INC | 01/18/2023 |
| DOB NOW | Earth Work | Signed-off | S & U MANAGEMENT INC | 06/01/2022 |
| DOB NOW | Construction Fence | Signed-off | DESIGN N SAFETY INC | 05/02/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 12/12/2023 | Permit Issued | S & U MANAGEMENT INC | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Mitsubishi Electric MXZ-3C30NA3 28,400 BTU · Condensing Unit ×16 MXZ-4C36NA3 35,400 BTU · Heat Pump Outdoor ×6 MXZ-3C24NA3 22,000 BTU · Condensing Unit ×1 Heating Mitsubishi Electric MXZ-3C30NA3 28,600 BTU · Condensing Unit ×16 MXZ-4C36NA3 36,000 BTU · Condensing Unit ×6 MXZ-3C24NA3 25,000 BTU · Condensing Unit ×1 Ventilation |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/12/2023 | Signed-off | BRUCHE MECHANICAL NY LLC | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/04/2023 | Complete | POWER DIRECT ELECTRIC INC | — |
| 03/02/2023 | Complete | POWER DIRECT ELECTRIC INC | General Wiring |
| 02/20/2023 | Complete | POWER DIRECT ELECTRIC INC | — |
| 01/30/2023 | Complete | SOLAS ELECTRICAL CORP | — |
| Date | Type | Result | Report |
|---|---|---|---|
| 07/23/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 10/31/2023 | Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve Test | Certified | View ↗ |
| 10/19/2023 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 10/17/2023 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 10/16/2023 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 09/08/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 09/05/2023 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 08/30/2023 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 05/04/2023 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 05/04/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 01/23/2023 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 01/23/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 12/15/2023 | Shutoff dampers | FAHAD FATEH | energy_progress |
| 12/15/2023 | HVAC-R and service water piping design and insulation | FAHAD FATEH | energy_progress |
| 12/15/2023 | HVAC-R and service water heating equipment | FAHAD FATEH | energy_progress |
| 12/15/2023 | Heating Systems | FAHAD FATEH | special |
| 12/15/2023 | Mechanical Systems | FAHAD FATEH | special |
| 12/15/2023 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 12/15/2023 | Final | FAHAD FATEH | progress |
| 12/15/2023 | Energy Code Compliance Inspections | FAHAD FATEH | progress |
| 12/15/2023 | Maintenance information | FAHAD FATEH | energy_progress |
| 12/15/2023 | HVAC-R and service water heating system controls | FAHAD FATEH | energy_progress |
| 11/08/2023 | Interior lighting power | FAHAD FATEH | energy_progress |
| 11/08/2023 | Air barrier - visual inspection | FAHAD FATEH | energy_progress |
| 11/08/2023 | Lighting controls | FAHAD FATEH | energy_progress |
| 11/08/2023 | Fenestration air leakage | FAHAD FATEH | energy_progress |
| 11/08/2023 | Fenestration and door U-factor and product ratings | FAHAD FATEH | energy_progress |
| 11/08/2023 | Insulation placement and R values | FAHAD FATEH | energy_progress |
| 11/08/2023 | Maintenance information | FAHAD FATEH | energy_progress |
| 11/08/2023 | Fenestration areas | FAHAD FATEH | energy_progress |
| 11/08/2023 | Air barrier — testing | FAHAD FATEH | energy_progress |
| 11/08/2023 | Exterior lighting power | FAHAD FATEH | energy_progress |
| 11/08/2023 | Lighting in dwelling units | FAHAD FATEH | energy_progress |
| 11/08/2023 | Fire-Resistance Rated Construction | FAHAD FATEH | progress |
| 11/08/2023 | Energy Code Compliance Inspections | FAHAD FATEH | progress |
| 11/08/2023 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 11/08/2023 | Sprayed fire-resistant materials | FAHAD FATEH | special |