← Back
Miscellaneous one family
1639 WEST 3 STREET
BROOKLYN · Gravesend (West) · BIN 3175766
💬 Discuss this project
1920Year Built
2Stories
A9Building Class
R4AZoning
1,400 sfGross Floor Area
1Units
Miscellaneous one family · 2,000 sf lot · 0.7 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 212p · 2 filings · 15 docs
Floor 112p · 2 filings · 15 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/19/2022$880K—Private party → Private party$629/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ENTHINK ENGINEERS LLC405/31/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
H-BUILDER INCGeneral Contractor107/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENTHINK ENGINEERS LLC6247405/31/2023
Building Lifecycle
All (18)Filed (4)Permit Issued (2)Signed Off (2)Inspection (7)Special Inspection (3)
07/13/2023
Signed off — Alteration
FILING FOR PLUMBING WORK TYPE FOR THE INTERIOR RENOVATION AT CELLAR, 1ST & 2ND FLOOR OF AN EXISTING 2 STORY ONE FAMILY HOUSE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00817623-I1
07/10/2023
Signed off — Alteration
INTERIOR RENOVATION AT 1ST & 2ND FLOOR OF AN EXISTING 2 STORY ONE FAMILY HOUSE. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00814482-I1
07/07/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/07/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/07/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/05/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
06/01/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Sunil Saigal
05/31/2023
Filed — Alteration
INTERIOR RENOVATION AT 1ST & 2ND FLOOR OF AN EXISTING 2 STORY ONE FAMILY HOUSE. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00814482-P1
05/10/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Sunil Saigal
03/20/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/20/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/20/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Sunil Saigal
03/13/2023
Filed — Alteration
FILING FOR PLUMBING WORK TYPE FOR THE INTERIOR RENOVATION AT CELLAR, 1ST & 2ND FLOOR OF AN EXISTING 2 STORY ONE FAMILY HOUSE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00817623-P1
02/02/2023
Permit issued — Plumbing
B00817623-I1-PL
01/31/2023
Filed — Alteration
FILING FOR PLUMBING WORK TYPE FOR THE INTERIOR RENOVATION AT CELLAR, 1ST & 2ND FLOOR OF AN EXISTING 2 STORY ONE FAMILY HOUSE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00817623-I1
01/24/2023
Permit issued — General Construction
B00814482-I1-GC
01/21/2023
Filed — Alteration
INTERIOR RENOVATION AT 1ST & 2ND FLOOR OF AN EXISTING 2 STORY ONE FAMILY HOUSE. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00814482-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.02/02/2023
DOB NOWGeneral ConstructionSigned-offH-BUILDER INC01/24/2023
1 project · most recent 01/11/2023
FiledStatusContractorScope
01/11/2023CompleteGOODALL ELECTRIC CORP1 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
07/07/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/07/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/07/2023Pass-Final General Construction Non-Directive 14PassView ↗
06/05/2023Fail-Final General Construction Non-Directive 14FailView ↗
03/20/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/20/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/20/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
06/01/2023Fire-Resistant Penetrations and JointsSunil Saigalspecial
05/10/2023Fire-Resistant Penetrations and JointsSunil Saigalspecial
03/14/2023Fire-Resistant Penetrations and JointsSunil Saigalspecial
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026B00814482-P1Request digital key ↗
08/27/2026B00814482-I1Request digital key ↗
08/27/2026B00817623-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026B00814482-P1Open ↗
08/27/2026B00814482-I1Open ↗
08/27/2026B00817623-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/02/2026B00814482-P1Open ↗
09/01/2026B00817623-I1Open ↗
08/27/2026B00814482-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/27/2026B00814482-P1Open ↗
08/27/2026B00814482-I1Open ↗
08/27/2026B00817623-P1Open ↗
Showing 3 of 4 on file for this type