| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 01/22/2021 | $750K | — | — → — | $496/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| LI ARCHITECT ASSOCIATE, PLLC | 6 | 08/31/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| HAOTIAN & ASSOCIATES INC. | 3 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| SPLEN CONSTRUCTION INC | General Contractor | 2 | 07/08/2026 |
| VILLAGE P & H NY INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| LI ARCHITECT ASSOCIATE, P | 1104 | 3 | 02/03/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | VILLAGE P & H NY INC | 02/10/2022 |
| DOB NOW | General Construction | Signed-off | SPLEN CONSTRUCTION INC | 12/16/2021 |
| DOB NOW | General Construction | Permit Issued | SPLEN CONSTRUCTION INC | 09/10/2021 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/30/2021 | Complete | R & T ELECTRICAL CORP | — |
| Date | Type | Result | Report |
|---|---|---|---|
| 05/04/2023 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 05/26/2022 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 05/17/2022 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 03/09/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 03/09/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/09/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 10/28/2021 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 10/14/2021 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 10/11/2021 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 02/10/2022 | Fire-Resistant Penetrations and Joints | Ling Li | special |
| 02/10/2022 | Energy Code Compliance Inspections | Ling Li | progress |
| 02/10/2022 | Fire-Resistance Rated Construction | Ling Li | progress |
| 02/10/2022 | Air barrier - visual inspection | Ling Li | energy_progress |
| 02/10/2022 | Fenestration areas | Ling Li | energy_progress |
| 02/10/2022 | Fenestration and door U-factor and product ratings | Ling Li | energy_progress |
| 02/10/2022 | Maintenance information | Ling Li | energy_progress |
| 02/10/2022 | Insulation placement and R values | Ling Li | energy_progress |
| 02/10/2022 | Fenestration air leakage | Ling Li | energy_progress |
| 02/10/2022 | Interior lighting power | Ling Li | energy_progress |
| 02/02/2022 | Fire-Resistant Penetrations and Joints | Ling Li | special |
| 02/02/2022 | Energy Code Compliance Inspections | Ling Li | progress |
| 02/02/2022 | Fire-Resistance Rated Construction | Ling Li | progress |
| 02/02/2022 | Fenestration areas | Ling Li | energy_progress |
| 02/02/2022 | Air barrier - visual inspection | Ling Li | energy_progress |
| 02/02/2022 | Fenestration air leakage | Ling Li | energy_progress |
| 02/02/2022 | Insulation placement and R values | Ling Li | energy_progress |
| 02/02/2022 | Maintenance information | Ling Li | energy_progress |
| 02/02/2022 | Interior lighting power | Ling Li | energy_progress |
| 02/02/2022 | Fenestration and door U-factor and product ratings | Ling Li | energy_progress |
| 06/01/2021 | Concrete - Cast-In-Place | Ling Li | special |
| 06/01/2021 | Fire-Resistant Penetrations and Joints | Ling Li | special |
| 06/01/2021 | Energy Code Compliance Inspections | Ling Li | progress |
| 06/01/2021 | Fire-Resistance Rated Construction | Ling Li | progress |
| 06/01/2021 | Air barrier - visual inspection | Ling Li | energy_progress |