← Back
One family attached or semi-detached
164-43 73 AVENUE
QUEENS · BIN 4150681
💬 Discuss this project
1940Year Built
2Stories
A5Building Class
R3-2Zoning
1,464 sfGross Floor Area
1Units
One family attached or semi-detached · 1,800 sf lot · 0.81 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 26p · 1 filing · 20 docs
Floor 1
1 job · most recent 12/19/2025
Gas Water/Sanitary
FiledStatusContractorScope
12/19/2025Signed-offLEFKES WATER WORKS INCGas, Water/Sanitary
1 job · most recent 04/09/2026
General Wiring
FiledStatusContractorScope
04/09/2026CompleteTESTA ELECTRIC CO., INCGeneral Wiring
1 job · most recent 12/19/2025
FiledStatusContractorScope
12/19/2025Signed-offLEFKES WATER WORKS INC2 scope_items
Building Lifecycle
All (36)Filed (4)Permit Issued (3)Signed Off (1)Inspection (4)Special Inspection (24)
03/25/2026
Signed off — Alteration
Proposed plumbing work -kitchen replacement at first floor and laundry at cellar
Q01130604-S1
01/30/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/23/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/19/2025
Filed — Alteration
Proposed plumbing work -kitchen replacement at first floor and laundry at cellar
Q01130604-P2
12/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Arnold Montag
12/19/2025
Special inspection requirement — Masonry
Arnold Montag
12/19/2025
Special inspection requirement — Concrete - Cast-In-Place
Anthony Marmo
12/19/2025
Special inspection requirement — Final
Arnold Montag
12/19/2025
Special inspection requirement — Footing and Foundation
Anthony Marmo
12/19/2025
Special inspection requirement — Energy Code Compliance Inspections
Arnold Montag
12/19/2025
Special inspection requirement — Fire-Resistance Rated Construction
Arnold Montag
12/19/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Arnold Montag
12/19/2025
Special inspection requirement — Air barrier - visual inspection
Arnold Montag
12/19/2025
Special inspection requirement — Fenestration areas
Arnold Montag
12/19/2025
Special inspection requirement — Interior lighting power
Arnold Montag
12/19/2025
Special inspection requirement — Fenestration air leakage
Arnold Montag
12/12/2025
Special inspection requirement — Concrete - Cast-In-Place
Anthony Marmo
12/12/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Arnold Montag
12/12/2025
Special inspection requirement — Masonry
Arnold Montag
12/12/2025
Special inspection requirement — Energy Code Compliance Inspections
Arnold Montag
12/12/2025
Special inspection requirement — Final
Arnold Montag
12/12/2025
Special inspection requirement — Fire-Resistance Rated Construction
Arnold Montag
12/12/2025
Special inspection requirement — Footing and Foundation
Anthony Marmo
12/12/2025
Special inspection requirement — Fenestration air leakage
Arnold Montag
12/12/2025
Special inspection requirement — Fenestration areas
Arnold Montag
12/12/2025
Special inspection requirement — Air barrier - visual inspection
Arnold Montag
12/12/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Arnold Montag
12/12/2025
Special inspection requirement — Interior lighting power
Arnold Montag
12/08/2025
Permit issued — Plumbing
Q01130604-S1-PL
12/05/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/19/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/04/2025
Permit issued — Plumbing
Q01130604-S1-PL
09/02/2025
Filed — Alteration
Proposed plumbing work -kitchen replacement at first floor and laundry at cellar
Q01130604-P1
06/06/2025
Permit issued — General Construction
Q01130604-I1-GC
11/11/2024
Filed — Alteration
Proposed plumbing work -kitchen replacement at first floor and laundry at cellar
Q01130604-S1
10/28/2024
Filed — Alteration
Proposed plumbing work -kitchen replacement at first floor and laundry at cellar
Q01130604-I1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARNOLD MONTAG ARCHITECT AM/PM DESI412/19/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LEFKES WATER WORKS INCPlumbing207/08/2026
TESTA ELECTRIC CO., INCElectrical103/22/2026
S & G CONTRACTING MANAGEMENTGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AFM INSPECTIONS & ENGINEE4675212/19/2025
ARNOLD MONTAG ARCHITECT,4599212/19/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offLEFKES WATER WORKS INC12/08/2025
DOB NOWPlumbingSigned-offLEFKES WATER WORKS INC09/04/2025
DOB NOWGeneral ConstructionSigned-offS & G CONTRACTING MANAGEM06/06/2025
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
01/30/2026Pass-Final General Construction Non-Directive 14PassView ↗
12/23/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/05/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/19/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
12/19/2025Fire-Resistant Penetrations and JointsArnold Montagspecial
12/19/2025MasonryArnold Montagspecial
12/19/2025Concrete - Cast-In-PlaceAnthony Marmospecial
12/19/2025FinalArnold Montagprogress
12/19/2025Footing and FoundationAnthony Marmoprogress
12/19/2025Energy Code Compliance InspectionsArnold Montagprogress
12/19/2025Fire-Resistance Rated ConstructionArnold Montagprogress
12/19/2025Fenestration and door U-factor and product ratingsArnold Montagenergy_progress
12/19/2025Air barrier - visual inspectionArnold Montagenergy_progress
12/19/2025Fenestration areasArnold Montagenergy_progress
12/19/2025Interior lighting powerArnold Montagenergy_progress
12/19/2025Fenestration air leakageArnold Montagenergy_progress
12/12/2025Concrete - Cast-In-PlaceAnthony Marmospecial
12/12/2025Fire-Resistant Penetrations and JointsArnold Montagspecial
12/12/2025MasonryArnold Montagspecial
12/12/2025Energy Code Compliance InspectionsArnold Montagprogress
12/12/2025FinalArnold Montagprogress
12/12/2025Fire-Resistance Rated ConstructionArnold Montagprogress
12/12/2025Footing and FoundationAnthony Marmoprogress
12/12/2025Fenestration air leakageArnold Montagenergy_progress
12/12/2025Fenestration areasArnold Montagenergy_progress
12/12/2025Air barrier - visual inspectionArnold Montagenergy_progress
12/12/2025Fenestration and door U-factor and product ratingsArnold Montagenergy_progress
12/12/2025Interior lighting powerArnold Montagenergy_progress
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026Q01130604-I1Request digital key ↗
08/21/2026Q01130604-P2Request digital key ↗
08/21/2026Q01130604-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026Q01130604-P1Open ↗
08/13/2026Q01130604-S1Open ↗
▸Seals & Professional Certifications16
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026Q01130604-I1Open ↗
09/01/2026Q01130604-I1Open ↗
09/01/2026Q01130604-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/01/2026Q01130604-I1Open ↗
09/01/2026Q01130604-I1Open ↗
09/01/2026Q01130604-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/21/2026Q01130604-P2Open ↗
08/21/2026Q01130604-P1Open ↗
08/21/2026Q01130604-S1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/21/2026Q01130604-P2Open ↗
08/21/2026Q01130604-P1Open ↗
08/21/2026Q01130604-S1Open ↗
Showing 3 of 4 on file for this type