ECB07/21/2026CLASS 1 C/U: DOOR ZONE RESTRICTOR INOPERATIVE AS PER ASME A17.1 2.12.5, A SAFETY FEATURE PREVENTING CAR DOORS FROM OPENING WHEN THE CAR IS OUT OF THE DOOR ZONE. CONTROLLER F10 FUSE BYPASSED, CREATING AN UNSAFE$1K due
HPD05/18/2026§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATHROOM AND IN THE KITCHEN LOCATED AT APT 18C , 16th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/15/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 9H, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD03/18/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM EAST LOCATED AT APT 9H, 10th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD02/24/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE HARD WOOD FLOOR IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 9H, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD02/24/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 2nd APARTMENT FROM EAST AT SOUTH
HPD02/24/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE AT RADIATOR IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 9H, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD08/03/2025§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INOPERATIVE BEL, BUZZER, INTERCOM SYSTEM FROM 1ST STORY PUBLIC HALL VESTIBULE TO RECEIVING PANEL AT EAST WALL IN THE FOYER LOCATED AT APT 9H, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD08/03/2025§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHENETTE LOCATED AT APT 9H, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD03/03/2025§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES (AT RANGE) IN THE KITCHENETTE LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD02/05/2025§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2B, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD09/23/2024§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 9H, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD03/17/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
DOB10/04/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB10/04/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
HPD06/11/2023HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT APT1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD06/11/2023HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT APT1A, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
DOB04/25/2023AT PARKING GARAGE LEVELS CRACKS AND EXPOSED REBAR AT UNDERSIDE OF ROOF LEVEL AT VARIUOS LOCATIONS AT TIME OF INSPECTION
HPD01/13/2023§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD01/13/2023§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD11/04/2022§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL AND BUZZER SYSTEM FROM BUILDING VESTIBULE TO APT 9H IN THE PRIVATE HALLWAY LOCATED AT APT APT9H, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD11/04/2022§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES CRACKED IN THE KITCHEN LOCATED AT APT APT9H, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD10/04/2021§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CABINET PPROXIMATELY 10 SQ.FTT IN THE KITCHEN LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD10/04/2021§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELEAN SURFACE AT THE INTERIOR AT BATHTUB IN THE BATHROOM LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
DOB09/01/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/01/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/09/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/08/2021VACATE ORDER: DUE TO HAZARDOUS POSED BY DEFECTIVE BALCONIES ON EXP 2 AND 4 THERE ARE CRACKED SPALLED DAMAGED CONCRETE SLABS ON VARIOUS BALCONIES, DAMAGED BALCONY RAILINGS CONNECTIONS TO SLAB IN SEVERAL LOCATIONS. ALL BALCONIES MUST BE VACATED IMMED. REMEDY: IMMED VACATE ALL BALCONIES UNTIL ALL DEFECTIVE CONDITIONS HAVE BEEN REMEDIED
ECB06/08/2021FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES AS NOTED BUILDING HAS DEFECTIVE BALCONIES THROUGHOUT EXPOSURE 2 AND 4 DEMAGED/CRACKED BALCONY RAILING SUPPORTS CONNECTIONS TO BALCONY SLABS.BALCONI$2K due
ECB06/08/2021FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED AS NOTED:EXPOSURE 2 NOPROTECTION PROVIDED UNDER BALCONIES IN PLAYGROUND SIDEWALK SHED NEEDS TO BE PROVIDED APPROX. 35FT BALCONIES ARE IN DISREPAIR CRACKED AND SPA$10K due
DOB06/08/2021ON 06/08/2021 FOUND CRACKED, SPALLED AND DISLODGED BALCONY SLAB CONCRETE AT VARIOUS LEVELS THAT WHERE HAZARDOUS AND INDICATE A SYSTEMATIC CONDITION ON THE BUILDING. REMEDY: OWNER TO IMMED RETAIN NYS LIC PROF TO INSPECT 100% OF ALL BALCONIES BY HAND AND EVALUATE BALCONY CONDITIONS. REPORT TO BE SUBMITTED TO FACADE UNIT
HPD05/24/2021§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF A LOCKABLE SLIDE BOLT INSTALLED ON DOOR IN THE ENTRANCE LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH
ECB05/12/2021FAILURE TO MAINTAIN EXTERIOR BLDG WALLS&APPURTENANCES.NOTED:ATOI I OBSERVED ON EXP1:DAMAGED,MISSING JOINTS ON SEVERAL FL EXP2:CRACKS ON BALCONY SLABS@SEVERAL FLS.EXP3:SPALLING CONCRETE ON PARAPET,DAMAGE MORTAR$1K due
DOB04/29/2021FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
ECB03/11/2021FAILURE TO TAKE AND PROVIDE ADEQUATE SAFETY MEASURES WHERE REQUIRED FROM DOCUMENTED UNSAFE FACADE THE TECHNICAL REPORT (FISP 3 NOTIFICATION UNSAFE) FILLED BY PE/RA FILED FACADES UNSAFE INADEQUATE SAFETY MEASURE$25K due
DOB09/16/2020V-DOB VIOLATION - ACTIVE
DOB09/16/2020V-DOB VIOLATION - ACTIVE
DOB01/31/2019CYCLE 8 NRF
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
HPD06/08/2016§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH
DOB08/30/2013FAILED TO FILE FISP CYCLE 7B TECHNICAL REPORT BY 08/21/2012
DOB01/22/1991DEVICE #2P4037
DOB01/22/1991DEVICE #2P4036
ECB04/25/2023AT THE PARKING GARAGE THE CONCRETE SLABS AT ALL LEVELS, THE ROOF LEVELUNDERSIDE CONCRETE SLAB HAS REBAR SHOWING AT TIME OF INSPECTION, REPAIR AND/REPLACE; REPAIR/MAINATAIN BUILDINGNothing owed — awaiting certificate of correction
ECB12/13/2022UPON INSPECTION, OBSERVED ACTIVE SUSPENDED SCAFFOLDS AT EXPOSURE 1 AND 2. AFTER DOING PERIMETER INSPECTION NOTICE A HILL WITHOUT GUARDRAIL OR ANY TYPE OF SIGN WHICH IS CONTRARY TO SITE SAFETY PLAN IT SHOWS A CONothing owed — awaiting certificate of correction
ECB12/13/2022UPON INSPECTION, OBSERVED A ROPE ATTACHED TO A CHAIN LINK FENCE POST ON BOTH SIDES. THIS ROPE IS USE AS A FALL PROTECTION FOR WORKERS WHEN THEY INGRESS OR EGRESS AN UNSAFE HILL. THERE IS NO APPROVED DRAWINGS FONothing owed — awaiting certificate of correction
ECB10/27/2014FAILURE TO MAINTAIN EXTERIOR EAST ELEV. EXP1 BRICK BULGING OVER LINTEL6 FLR/8 FLR - BRICK NOT FLUSH. SOUTH ELEVATION-EX#2 BALCONY'S CORNER POSTS RUSINT AT LINE CLOSEST TO UNDERCLIFF AVENUE. WEST ELEV. EXP#3 CHNothing owed — awaiting certificate of correction
ECB05/13/2013FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES-NOTED 1A-STEPCRACKS AT UPPER SECTION OF BRICKWORK @ CHIMNEY STACK AT NORTH ELEVN; B-CROOKED METAL SHEATHING AT CHIMNEY CAP AT WEST ELEVN; 2-IMPROPERLY INSTALLED ANothing owed — awaiting certificate of correction