← Back
Sign in
Build
NYC
Miscellaneous educational facility
1659 ZEREGA AVENUE
BRONX · BIN 2042063
💬 Discuss this project
1928
Year Built
2
Stories
W9
Building Class
R6
Zoning
1,120 sf
Gross Floor Area
1
Units
0 Active Violations
Miscellaneous educational facility · 5,441 sf lot · 0.21 FAR built · Flood zone X
Floor Stack
2
People & Firms
3
Timeline
38
Permits & Filings
0
Scope of Work
0
Inspections
0
Documents
20
Locations of Work
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Cellar
2 filings
Filed — no permit issued
2 filings
Design Consultants
2
Filing Representatives
1
▾
Design Consultants (Architect / Engineer of Record)
Firm
Filings
Most Recent
MFS Consulting Engineers & Surveyor
2
10/07/2026
Ancora Engineering
2
02/10/2026
▾
Filing Representatives (Expediters)
Representative
Filings
Most Recent
NYC School Construction Authority
3
03/21/2026
Building Lifecycle
All (38)
Filed (4)
Violation (6)
Objection (4)
Special Inspection (15)
10/19/2026
Objection raised — Other
10/07/2026
Filed — Alteration
X01461934-I1
09/25/2026
Special inspection requirement — Subgrade Inspections
09/25/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
09/25/2026
Special inspection requirement — Deep Foundation Elements
09/25/2026
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
09/25/2026
Special inspection requirement — Concrete - Cast-In-Place
09/25/2026
Special inspection requirement — Concrete - Precast
09/25/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
09/25/2026
Special inspection requirement — Structural Steel - Details
09/25/2026
Special inspection requirement — Structural Steel - Welding
09/24/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
09/17/2026
Special inspection requirement — Footing and Foundation
09/17/2026
Special inspection requirement — Final
02/23/2026
Objection raised — Other
02/23/2026
Objection resolved — Addressed
02/10/2026
Filed — Alteration
SUPPORT OF EXCAVATION IN CONJUNCTION WITH DEMO.
X01357438-I1
12/23/2025
Objection raised — Structural
12/18/2025
Filed — Alteration
X01333124-I1
12/12/2025
Special inspection requirement — Final
11/19/2025
Filed — Full Demolition
DEMOLITION OF 3 STORY BUILDING AT 1659 ZEREGA AVENUE.
X01320460-I1
11/18/2025
Special inspection requirement — Structural Stability – Alterations of existing Buildings
11/18/2025
Special inspection requirement — Demolition
09/22/2025
Closed: Violation issued for failure to file annual boiler 2016 inspection report
DOB violation · closed on the city's record
04/14/2025
Boiler inspection report filed
Initial · no defects · Accepted
08/07/2024
Boiler inspection report filed
Initial · no defects · Accepted
02/27/2023
Boiler inspection report filed
Initial · no defects · Accepted
02/10/2022
Boiler inspection report filed
Subsequent · no defects · Accepted
02/10/2022
Boiler inspection report filed
Initial · no defects · Accepted
02/10/2021
Boiler inspection report filed
Initial · defects found · Accepted
07/16/2020
Closed: Violation issued for failure to file annual boiler 2017 inspection report
DOB violation · closed on the city's record
01/10/2020
Boiler inspection report filed
Initial · no defects · Accepted
11/08/2019
Violation issued for failure to file annual boiler 2017 inspection report
DOB violation · closed · Issued 2019; DOB's record still lists it as active
01/24/2019
Boiler inspection report filed
Initial · no defects · Accepted
06/19/2018
B254,50A,50B. As per class 2 (B254) 28.301.1 failure to maintain. 50-hole in boiler room between ceiling and wall; 50B-expose electricalwires box…
ECB violation · closed
05/04/2018
Boiler inspection report filed
Initial · no defects · Accepted
04/06/2018
Violation issued for failure to file annual boiler 2016 inspection report
DOB violation · closed · Issued 2018; DOB's record still lists it as active
08/08/1989
Remove outlet pipe threading at end from safety relief valve. Installmetal screw at breeching section.
ECB violation · closed
Nothing on file for this building.
Nothing on file for this building.
Nothing on file for this building.
▾
Documents — 20 on file (BIS + DOB NOW)
▸
Plans & Drawings
4
▸
DOB NOW
Plans/Sketch
4
10/08/2026
X01461934-I1
Request the plans ↗
08/17/2026
X01320460-I1
Request the plans ↗
08/17/2026
X01333124-I1
Request the plans ↗
Showing 3 of 4 on file for this type
▸
Seals & Professional Certifications
4
▸
DOB NOW
DPL-1: Design Professional Seal & Signature
4
10/08/2026
X01461934-I1
Open ↗
08/17/2026
X01320460-I1
Open ↗
08/17/2026
X01333124-I1
Open ↗
Showing 3 of 4 on file for this type
▸
Approvals, Objections & Sign-offs
8
▸
DOB NOW
Fee Exempt Supporting Document - DOF ACRIS report or BIB letter
3
10/08/2026
X01461934-I1
Open ↗
08/17/2026
X01357438-I1
Open ↗
08/13/2026
X01333124-I1
Open ↗
▸
DOB NOW
Design Commission Approval City Owned (Exterior Work)
3
10/08/2026
X01461934-I1
Open ↗
08/17/2026
X01357438-I1
Open ↗
08/13/2026
X01333124-I1
Open ↗
▸
DOB NOW
Design Commission Sign Off City Owned (Exterior Work)
2
10/08/2026
X01461934-I1
Open ↗
08/17/2026
X01357438-I1
Open ↗
▸
Other Documents
4
▸
DOB NOW
NYCSCA - BCC Plan Examination Transmittal
3
10/08/2026
X01461934-I1
Open ↗
08/17/2026
X01357438-I1
Open ↗
08/13/2026
X01333124-I1
Open ↗
▸
DOB NOW
Property Ownership Certification
1
08/17/2026
X01320460-I1
Open ↗