← Back
BuildNYC
Two family converted from one family
166-10 120TH AVENUE
QUEENS · BIN 4268364
💬 Discuss this project
1930Year Built
2Stories
B3Building Class
R3AZoning
2,400 sfGross Floor Area
2Units
1 Active Violation ▸FDNY Report ↗
Two family converted from one family · 4,000 sf lot · 0.6 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofSignage and satellite dish installation8p · 2 filings · 20 docs
AtticHorizontal Enlargement. Conversion to Two-family Dwelling6p · 1 filing · 20 docs
Floor 2Horizontal Enlargement. Conversion to Two-family Dwelling6p · 1 filing · 20 docs
Floor 1Horizontal Enlargement. Conversion to Two-family Dwelling29p · 1 filing · 20 docs
CellarHorizontal Enlargement. Conversion to Two-family Dwelling10p · 1 filing · 20 docs
Site & exteriorHorizontal Enlargement. Conversion to Two-family Dwelling8p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Shafiqulislam307/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/20/2023$1.3M—YARAN HOMES CORP. → Private party$542/sf building
05/06/2022$500K—— → —$208/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Parker and West Engineering112/22/2023
CL Engineering606/13/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Metro Design1203/21/2026
Sunrun103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J&J DesignsGeneral Contractor207/08/2026
Sunrun Installation ServiceGeneral Contractor107/08/2026
J&J DesignsScaffold107/08/2026
All Pro Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Parker and West Engineering5272112/22/2023
CL Engineering6781406/13/2023
Triangle Inspection & Tes7495205/31/2023
Building Lifecycle
All (84)Filed (7)Permit Issued (5)Signed Off (4)Violation (5)Inspection (9)Objection (24)Special Inspection (30)
01/13/2026
Violation issued (HPD, closed)
I
01/03/2026
Violation issued (HPD, closed)
B
01/03/2026
Violation issued (HPD, closed)
B
01/03/2026
Violation issued (HPD, closed)
B
01/03/2026
Violation issued (ECB, open)
Construction
05/06/2024
Signed off — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00971334-I1
12/29/2023
Permit issued — Solar
Q00971334-I1-SL
12/22/2023
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00971334-I1
12/04/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Walid Abdulla
12/04/2023
Special inspection requirement — Energy Code Compliance Inspections
Walid Abdulla
12/04/2023
Special inspection requirement — Final
Walid Abdulla
12/04/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walid Abdulla
12/04/2023
Special inspection requirement — Air barrier - visual inspection
Walid Abdulla
09/11/2023
Signed off — Alteration CO
CONVERSION OF THE EXISTING TWO STORY ONE-FAMILY BUILDING INTO A TWO-STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00786612-S2
09/07/2023
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
07/26/2023
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
07/19/2023
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
07/14/2023
Permit issued — Curb Cut
Q00786612-S2-CC
07/11/2023
Signed off — Alteration CO
CONVERSION OF THE EXISTING TWO STORY ONE-FAMILY BUILDING INTO A TWO-STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00786612-S1
07/06/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/03/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH ALT APPLICATION TO BE FILED. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00784293-I1
06/22/2023
Special inspection requirement — Insulation placement and R values
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Fire-Resistance Rated Construction
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Electric vehicle service equipment requirements
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Heating Systems
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Mechanical Systems
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Final
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Structural Wood Frame
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Fenestration areas
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Air barrier - visual inspection
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Masonry
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
06/22/2023
Special inspection requirement — Subgrade Inspections
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Concrete - Cast-In-Place
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Structural Steel - Details
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Structural Steel - High Strength Bolting
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Energy Code Compliance Inspections
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Footing and Foundation
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Ventilation and air distribution system
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Interior lighting power
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — HVAC-R and service water heating equipment
CHRISTIAN LOZADA
06/22/2023
Special inspection requirement — Fenestration air leakage
CHRISTIAN LOZADA
06/20/2023
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
06/20/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/13/2023
Filed — Alteration CO
CONVERSION OF THE EXISTING TWO STORY ONE-FAMILY BUILDING INTO A TWO-STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00786612-P2
06/13/2023
Objection resolved — Addressed
06/08/2023
Objection resolved — Addressed
06/02/2023
Objection raised — Scope
06/02/2023
Objection raised — Zoning
05/31/2023
Filed — Alteration CO
CONVERSION OF THE EXISTING TWO STORY ONE-FAMILY BUILDING INTO A TWO-STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00786612-P1
03/03/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/03/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
03/03/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/26/2023
Objection raised — Scope
01/26/2023
Objection resolved — Addressed
01/26/2023
Objection raised — Structural
Latest 60 of 84 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSunrun Installation Service12/29/2023
DOB NOWCurb CutSigned-offJ&J Designs07/14/2023
DOB NOWPlumbingSigned-offAll Pro Plumbing & Heating01/13/2023
DOB NOWStructuralPermit IssuedJ&J Designs12/29/2022
DOB NOWConstruction FenceSigned-offJ&J Designs08/11/2022
1 project · most recent 06/13/2023
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/13/2023Signed-offJ&J DesignsAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
York YCD36B23S 36,000 BTU · Condensing Unit ×2
YCD60B22S 60,000 BTU · Condensing Unit ×2
Heating
York TM8E080B12MP11A 80,000 BTU · Furnace ×2
TM8E130D20MP11A 130,000 BTU · Furnace ×2
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×10
Delta Breeze SMT150 150 CFM · Exhaust Fan ×4
1 project · most recent 06/13/2023
Gas Storm Water/Sanitary
FiledStatusContractorScope
06/13/2023Signed-offAll Pro Plumbing & HeatingGas, Storm, Water/Sanitary
2 projects · most recent 12/22/2023
General Wiring
FiledStatusContractorScope
12/22/2023CompleteSunrun Solar Electl—
01/08/2023CompleteAyyub ElectricGeneral Wiring
1 project · most recent 06/13/2023
Steel Wood
FiledStatusContractorScope
06/13/2023Signed-offJ&J DesignsSteel, Wood
1 project · most recent 06/13/2023
Earthwork
FiledStatusContractorScope
06/13/2023Signed-offJ&J DesignsEarthwork
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
09/07/2023Pass-Final Curb Cut Non-Directive 14PassView ↗
07/26/2023Fail-Final Curb Cut Non-Directive 14FailView ↗
07/19/2023Fail-Final Curb Cut Non-Directive 14FailView ↗
07/06/2023Pass-Final CND-Occupancy InspectionPassView ↗
06/20/2023Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
06/20/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/03/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/03/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/03/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 77
DateRequirementInspectorRole
12/04/2023Fire-Resistant Penetrations and JointsWalid Abdullaspecial
12/04/2023Air barrier - visual inspectionWalid Abdullaenergy_progress
12/04/2023FinalWalid Abdullaprogress
12/04/2023Energy Code Compliance InspectionsWalid Abdullaprogress
12/04/2023Structural Stability – Alterations of existing buildingsWalid Abdullaspecial
06/22/2023Air barrier - visual inspectionCHRISTIAN LOZADAenergy_progress
06/22/2023Structural Stability – Alterations of existing buildingsCHRISTIAN LOZADAspecial
06/22/2023Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
06/22/2023Concrete - Cast-In-PlaceCHRISTIAN LOZADAspecial
06/22/2023Structural Steel - DetailsCHRISTIAN LOZADAspecial
06/22/2023Mechanical SystemsCHRISTIAN LOZADAspecial
06/22/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationCHRISTIAN LOZADAspecial
06/22/2023Structural Steel - High Strength BoltingCHRISTIAN LOZADAspecial
06/22/2023Heating SystemsCHRISTIAN LOZADAspecial
06/22/2023MasonryCHRISTIAN LOZADAspecial
06/22/2023Subgrade InspectionsCHRISTIAN LOZADAspecial
06/22/2023Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
06/22/2023Excavations - Sheeting, Shoring, and BracingCHRISTIAN LOZADAspecial
06/22/2023FinalCHRISTIAN LOZADAprogress
06/22/2023Energy Code Compliance InspectionsCHRISTIAN LOZADAprogress
06/22/2023Footing and FoundationCHRISTIAN LOZADAprogress
06/22/2023Structural Wood FrameCHRISTIAN LOZADAprogress
06/22/2023Fire-Resistance Rated ConstructionCHRISTIAN LOZADAprogress
06/22/2023Ventilation and air distribution systemCHRISTIAN LOZADAenergy_progress
06/22/2023Interior lighting powerCHRISTIAN LOZADAenergy_progress
Latest 25 of 77.
▾Documents — 64 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/26/2026Q00784293-I1Request digital key ↗
08/24/2026Q00786612-P2Request digital key ↗
08/23/2026Q00971334-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits2
▸BISBPP-5 - Authorization to the Department of Transportation1
02/07/2023440758208Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
12/12/2022440758208Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q00786612-P2Open ↗
08/13/2026Q00786612-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026Q00786612-P2Open ↗
08/13/2026Q00786612-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00786612-I1Open ↗
▸Seals & Professional Certifications25
▸DOB NOWProgress Inspector Seal & Signature9
08/28/2026Q00786612-P2Open ↗
08/28/2026Q00786612-P2Open ↗
08/27/2026Q00971334-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
08/28/2026Q00786612-P2Open ↗
08/28/2026Q00786612-P2Open ↗
08/27/2026Q00971334-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/24/2026Q00786612-P1Open ↗
08/24/2026Q00786612-I1Open ↗
08/24/2026Q00786612-S1Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
12/12/2022440758208Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/13/2026Q00786612-P2Open ↗
08/13/2026Q00786612-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/24/2026Q00786612-P2Open ↗
08/15/2026Q00786612-S1Open ↗
08/14/2026Q00786612-I1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026Q00786612-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/13/2026Q00786612-I1Open ↗
08/13/2026Q00786612-P2Open ↗
▸BISDOB FINAL INSPECTION REQUIRED1
09/12/2023440758208Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00786612-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCURB CUT (CC) SIGNOFF1
09/12/2023440758208Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q00971334-I1Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
12/12/2022440758208Open ↗
▸Other Documents10
▸DOB NOWSite Survey: Initial2
08/13/2026Q00786612-P2Open ↗
08/13/2026Q00786612-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q00786612-I1Open ↗
08/13/2026Q00786612-P2Open ↗
▸DOB NOWPlot Diagram2
08/13/2026Q00786612-P2Open ↗
08/13/2026Q00786612-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/24/2026Q00786612-P2Open ↗
08/14/2026Q00786612-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00786612-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00786612-I1Open ↗