← Back
BuildNYC
Miscellaneous warehouse
1660 BOONE AVENUE
BRONX · BIN 2010949
💬 Discuss this project
1959Year Built
2Stories
E9Building Class
R7AZoning
22,371 sfGross Floor Area
1Units
2 Active Violations ▸
Miscellaneous warehouse · Owner of record: Boone Avenue Flats · 10,906 sf lot · 2.05 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Whole building & multi-floor projectsThe Vaja Group2 filings
RoofRussa Realty Corp.Under Construction6p · 5 filings · 20 docs
Floor 6Jss Boone LLC2p · 3 filings · 1 doc
Floor 5Jss Boone LLC1p · 3 filings · 1 doc
Floor 4Jss Boone LLC3 filings · 1 doc
Floor 3Jss Boone LLC1p · 3 filings · 1 doc
Floor 2Russa Realty Corp.Under Construction5p · 4 filings · 20 docs
Floor 1Russa Realty Corp.Under Construction7p · 9 filings · 20 docs
CellarJss Boone LLC2p · 4 filings · 3 docs
Site & exteriorThe Vaja GroupUnder Construction2 filings · 2 docs
Filed — no permit issuedThe Vaja Group3 filings · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Vaja Group5209/13/2026
Russa Realty703/21/2026
1660 Boone Ave103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/04/2025$3.9M—OMKAR PROPERTIES LLC → BOONE AVENUE FLATS LLC$174/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Stephen B Jacobs Group1403/21/2026
YG Expediting1003/21/2026
SNR Expediting Design403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
City Wide Builders GroupScaffold707/15/2026
New American ConstructionScaffold303/21/2026
City Wide Builders GroupGeneral Contractor303/21/2026
Hexagon IndustriesGeneral Contractor204/09/2026
Forsure Electric NYElectrical203/21/2026
Hexagon IndustriesScaffold104/09/2026
N Tech Design of AmericaScaffold104/09/2026
Roman Electrical ContractingElectrical103/21/2026
Target Piping NYFire Protection107/08/2026
HMF VenturesGeneral Contractor106/28/2026
N Tech Design of AmericaGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
H & O Engineering5595205/27/2026
Mje Consulting Engineering8522112/31/2024
Building Lifecycle
All (151)Filed (24)Permit Issued (12)Signed Off (1)Violation (36)Inspection (1)Objection (47)Special Inspection (30)
07/23/2026
Violation issued (ECB, open)
Construction
07/14/2026
Permit issued — Construction Fence
X01251778-I1-FN
07/13/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/03/2026
Objection raised — Other
05/27/2026
Filed — Full Demolition
MECHANICAL MEANS SUBMITTED FOR USE OF MECHANICAL EQUIPMENT ON GRADE AT THE TIME OF DEMOLITION
X01146043-P1
05/27/2026
Permit issued — Full Demolition
X01146043-I1-FD
05/26/2026
Violation issued (ECB, closed)
Construction
05/26/2026
Violation issued (ECB, open)
Construction
05/07/2026
Special inspection requirement — Duct leakage testing, insulation and design
05/07/2026
Special inspection requirement — Maintenance information
04/14/2026
Special inspection requirement — Demolition
SANTIAGO HELMAN
04/14/2026
Special inspection requirement — Structural Stability – Alterations of existing Buildings
SANTIAGO HELMAN
04/14/2026
Special inspection requirement — Construction Operations Influencing Adjacent Structures
SANTIAGO HELMAN
04/06/2026
Signed off — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
X01273140-I1
02/03/2026
Permit issued — Protection and Mechanical Methods
X01146043-S1-PMM
01/23/2026
Permit issued — Full Demolition
X01146043-I1-FD
01/22/2026
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
X01273140-P1
01/22/2026
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/22/2026
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/12/2026
Permit issued — Full Demolition
X01146043-I1-FD
12/17/2025
Violation issued (ECB, closed)
Construction
10/15/2025
Violation issued (ECB, closed)
Unknown
10/15/2025
Violation issued (ECB, closed)
Construction
10/15/2025
Violation issued (ECB, closed)
Unknown
09/09/2025
Objection raised — Other
08/22/2025
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
X01273140-I1
08/22/2025
Permit issued — Sidewalk Shed
X01273140-I1-SH
08/11/2025
Objection resolved — Addressed
08/07/2025
Permit issued — Full Demolition
X01146043-I1-FD
08/07/2025
Objection raised — Plumbing
08/06/2025
Filed — New Building
Temporary Standpipe Work Type filed in conjunction with NB GC# X00685698-I1
X01150558-S2
08/06/2025
Permit issued — Protection and Mechanical Methods
X01146043-S1-PMM
07/30/2025
Objection resolved — Addressed
07/30/2025
Objection resolved — Addressed
07/30/2025
Special inspection requirement — HVAC-R and service water heating equipment
07/30/2025
Special inspection requirement — Shutoff dampers
07/30/2025
Special inspection requirement — Fire-Resistance Rated Construction
07/30/2025
Special inspection requirement — Heating Systems
07/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/30/2025
Special inspection requirement — Energy Code Compliance Inspections
07/30/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
07/30/2025
Special inspection requirement — HVAC-R and service water heating system controls
07/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/30/2025
Special inspection requirement — Energy Code Compliance Inspections
07/30/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
07/29/2025
Permit issued — Sprinklers
X01159967-I1-EW-SP
07/24/2025
Permit issued — Construction Fence
X01251778-I1-FN
07/24/2025
Objection resolved — Addressed
07/17/2025
Filed — New Building
Temporary Standpipe Work Type filed in conjunction with NB GC# X00685698-I1
X01150558-S3
07/17/2025
Filed — New Building
Temporary Standpipe Work Type filed in conjunction with NB GC# X00685698-I1
X01150558-S4
07/15/2025
Objection raised — Admin
07/15/2025
Objection raised — Zoning
07/09/2025
Filed — Alteration
X01241787-I1
07/09/2025
Filed — Alteration
Proposed construction fence. No change to use, egress or occupancy under this application.
X01251778-I1
07/08/2025
Filed — New Building
Temporary Standpipe Work Type filed in conjunction with NB GC# X00685698-I1
X01150558-S1
07/08/2025
Special inspection requirement — Standpipe Systems
07/08/2025
Special inspection requirement — Sprinkler Systems
07/07/2025
Special inspection requirement — Standpipe Systems
07/07/2025
Special inspection requirement — Mechanical Systems
07/07/2025
Special inspection requirement — Final
Latest 60 of 151 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedCity Wide Builders Group07/14/2026
DOB NOWFull DemolitionPermit IssuedHMF Ventures05/27/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedN Tech Design of America02/03/2026
DOB NOWFull DemolitionPermit IssuedN Tech Design of America01/23/2026
DOB NOWFull DemolitionPermit IssuedHexagon Industries01/12/2026
DOB NOWSidewalk ShedSigned-offNew American Construction08/22/2025
DOB NOWFull DemolitionPermit IssuedHexagon Industries08/07/2025
DOB NOWProtection and Mechanical MethodsPermit IssuedHexagon Industries08/06/2025
DOB NOWSprinklersPermit IssuedTarget Piping NY07/29/2025
DOB NOWConstruction FencePermit IssuedCity Wide Builders Group07/24/2025
DOB NOWConstruction FencePermit IssuedCity Wide Builders Group06/26/2025
DOB NOWEarth WorkPermit IssuedCity Wide Builders Group12/19/2024
BISPLISSUEDTop Dog Plumbing & Heating10/23/2012
BISSPISSUEDSunset PLGB. & Fire08/17/2010
BISSPISSUEDSunset Plumbing & Fire Protection09/19/2008
BISSPISSUEDSunset Plumbing & Fire Protection12/11/2006
2 projects · most recent 08/06/2025
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScope
08/06/2025——Air Conditioning Systems, Heating Systems, Ventilation Systems
03/05/2020——Air Conditioning Systems
2 projects · most recent 08/06/2025
Sprinkler System
FiledStatusContractorScope
08/06/2025——Sprinkler System
03/06/2020——501 heads, 1 outlets
2 projects · most recent 08/06/2025
Storm Water/Sanitary Gas
FiledStatusContractorScope
08/06/2025——Gas, Storm, Water/Sanitary
03/05/2020——Storm, Water/Sanitary
2 projects · most recent 01/06/2026
General Wiring
FiledStatusContractorScope
01/06/2026Permit IssuedForsure Electric NYGeneral Wiring
08/26/2025CompleteRichard Neu—
3 projects · most recent 07/09/2025
Fence
FiledStatusContractorScope
07/09/2025Permit IssuedCity Wide Builders GroupFence
06/24/2025Permit IssuedCity Wide Builders GroupFence
12/17/2019——Fence
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
07/13/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 44
DateRequirementInspectorRole
05/07/2026Duct leakage testing, insulation and design—energy_progress
05/07/2026Maintenance information—energy_progress
04/14/2026DemolitionSANTIAGO HELMANspecial
04/14/2026Structural Stability – Alterations of existing BuildingsSANTIAGO HELMANspecial
04/14/2026Construction Operations Influencing Adjacent StructuresSANTIAGO HELMANspecial
07/30/2025HVAC-R and service water heating equipment—energy_progress
07/30/2025Shutoff dampers—energy_progress
07/30/2025Fire-Resistance Rated Construction—progress
07/30/2025Heating Systems—special
07/30/2025Fire-Resistant Penetrations and Joints—special
07/30/2025Energy Code Compliance Inspections—progress
07/30/2025Exterior Insulation and Finish Systems (EIFS)—special
07/30/2025HVAC-R and service water heating system controls—energy_progress
07/30/2025Fire-Resistant Penetrations and Joints—special
07/30/2025Energy Code Compliance Inspections—progress
07/30/2025HVAC-R and service water piping design and insulation—energy_progress
07/08/2025Standpipe Systems—special
07/08/2025Sprinkler Systems—special
07/07/2025Standpipe Systems—special
07/07/2025Mechanical Systems—special
07/07/2025Final—progress
05/07/2025Lighting in dwelling units—energy_progress
05/07/2025Air barrier continuity plan testing—energy_progress
05/07/2025Lighting controls—energy_progress
05/07/2025Metering—energy_progress
Latest 25 of 44.
▾Documents — 127 on file (BIS + DOB NOW)
▸Plans & Drawings24
▸DOB NOWPlans/Sketch16
08/20/2026X01149509-I1Request digital key ↗
08/20/2026X01159967-I1Request digital key ↗
08/19/2026X01241790-I1Request digital key ↗
Showing 3 of 16 on file for this type
▸DOB NOWPlans/Sketch - Place of Assembly3
08/15/2026X00308260-I1Request digital key ↗
08/15/2026X00308273-I1Request digital key ↗
08/14/2026X00308282-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/26/2026X00258971-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Standpipe1
08/15/2026X00259411-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
08/15/2026X00256060-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/26/2026X00259180-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler1
08/15/2026X00259411-I1Request digital key ↗
▸Applications & Permits12
▸BISPLAN / WORK APPROVAL APPLICATION10
01/22/2026240364146Open ↗
03/04/2020210180089Open ↗
12/18/2019210180089Open ↗
Showing 3 of 10 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation1
12/12/2019240263870Open ↗
▸BISWORK PERMIT APPLICATION1
10/23/2012220171034Open ↗
▸Zoning, Tax Lot & Property Records4
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
10/30/2019210180089Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026X01150558-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X01150558-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026X01150558-I1Open ↗
▸Seals & Professional Certifications34
▸DOB NOWDPL-1: Design Professional Seal & Signature23
08/26/2026X00256060-I1Open ↗
08/26/2026X00308273-I1Open ↗
08/26/2026X00308282-I1Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
08/26/2026X01146043-I1Open ↗
08/26/2026X01146043-I1Open ↗
08/26/2026X01146043-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY-CERTIFICATION2
05/16/2012220171034Open ↗
04/18/2012220171034Open ↗
▸BISAPPLICANT OWNER SIGNATURE2
01/22/2026240364146Open ↗
12/12/2019240263870Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
01/22/2026240364146Open ↗
▸Trade Schedules & Equipment10
▸BISSCHEDULE B - PLUMBING2
08/28/2012220171034Open ↗
04/18/2012220171034Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
04/18/2012220171034Open ↗
04/18/2012220171034Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
11/17/2012220171034Open ↗
▸BIS* SEWER CONNECTION: DEP SD1 & SD21
02/24/2020210180089Open ↗
▸DOB NOWWater Cut-Off1
08/13/2026X01146043-I1Open ↗
▸DOB NOWElectric Cut-Off1
08/13/2026X01146043-I1Open ↗
▸DOB NOWGas Cut-Off1
08/13/2026X01146043-I1Open ↗
▸DOB NOWSewer Cut-Off1
08/13/2026X01146043-I1Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE CHECKLIST2
01/22/2026240364146Open ↗
09/30/2019210180089Open ↗
▸BISBPP: STREET TREES SITE PLAN1
01/22/2026240364146Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026X01150558-I1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/20/2026X01159967-I1Open ↗
08/16/2026X01146043-I1Open ↗
08/14/2026X01146043-P1Open ↗
▸DOB NOWOER: Notice to Proceed2
08/13/2026X00259180-I1Open ↗
08/13/2026X00256060-I1Open ↗
▸BISASBESTOS-CERTIFICATION (DEP ACP5)1
04/18/2012220171034Open ↗
▸DOB NOWRodent Control1
08/13/2026X01146043-I1Open ↗
▸Energy Compliance3
▸BISTR8: Energy Code Progress Inspections2
05/16/2012220171034Open ↗
04/18/2012220171034Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
09/30/2019210180089Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/30/2019210180089Open ↗
▸Approvals, Objections & Sign-offs6
▸BISSCHEDULE A - OCCUPANCY / USE5
03/04/2020210180089Open ↗
02/07/2020210180089Open ↗
11/15/2019210180089Open ↗
Showing 3 of 5 on file for this type
▸BISADMINISTRATIVE OBJECTIONS1
04/18/2012220171034Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
04/18/2012220171034Open ↗
▸Filing & Intake Forms10
▸BISADDITIONAL INFORMATION3
02/24/2020210180089Open ↗
12/12/2019210180089Open ↗
10/30/2019210180089Open ↗
▸BISEFILING COVER SHEET3
12/18/2019210180089Open ↗
10/03/2019210180089Open ↗
07/24/2019220690045Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET3
01/22/2026240364146Open ↗
12/12/2019240263870Open ↗
04/18/2012220171034Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
12/12/2019240263870Open ↗
▸Other Documents11
▸DOB NOWProperty Ownership Certification3
08/18/2026X01150558-I1Open ↗
08/16/2026X01146043-I1Open ↗
08/14/2026X01146043-P1Open ↗
▸DOB NOWStructure Photographs2
08/13/2026X01146043-I1Open ↗
08/13/2026X01146043-P1Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
12/12/2019240263870Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026X01149509-I1Open ↗
▸DOB NOWCommunity Board Notification1
08/13/2026X01146043-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026X01150558-I1Open ↗
▸DOB NOWFull Demo: 10-Day Notice1
08/13/2026X01146043-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026X01150558-I1Open ↗