1920Year Built
2.5Stories
K2Building Class
R2AZoning
10,500 sfGross Floor Area
1Units
3 Open Violations ▸FDNY Report ↗
Multi-story retail building (2+) · Owner of record: CHON REALTY CORP · 22,400 sf lot · 0.47 FAR built · Flood zone X
Locations of Work
Plumbing
Permit Issued — active, not yet Signed-off
Floor 1Under Construction1 filing
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CHON PROPERTIES109/30/2026
CHON ENGINEERING303/22/2026
CHON REALTY503/22/2026
RECEPTION HOUSE LLC1003/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/26/2014$4.9M—THE CENTRAL PRESBYTERIAN CHURCH OF MANHATTAN → CHON REALTY CORP$467/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHON ENGINEERING111/25/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CHON ENGINEERING103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TREND 21 MANAGEMENT INCGeneral Contractor303/21/2026
I DO PLUMBING & HTG INCPlumbing109/30/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CHON ENGINEERING PC2454111/25/2020
Building Lifecycle
All (43)Filed (1)Permit Issued (2)Signed Off (1)Violation (33)Special Inspection (6)
09/29/2026
Permit issued — Plumbing
Q01461469-S1-PL
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/28/2021
Violation issued (ECB, closed)
Boilers
01/07/2021
Signed off — Alteration
REMOVE EXISTING HVAC ROOFTOP UNIT AND REPLACE NEW 10 TON HVAC ROOFTOP UNIT ON EXISTING STEEL DUNNAGE CONNECT TO EXISTING DUCT ON THE ROOF. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00433338-I1
11/30/2020
Permit issued — Mechanical Systems
Q00433338-I1-MS
11/25/2020
Filed — Alteration
REMOVE EXISTING HVAC ROOFTOP UNIT AND REPLACE NEW 10 TON HVAC ROOFTOP UNIT ON EXISTING STEEL DUNNAGE CONNECT TO EXISTING DUCT ON THE ROOF. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00433338-I1
11/25/2020
Special inspection requirement — Mechanical Systems
Steve Chon
11/25/2020
Special inspection requirement — Final
Steve Chon
11/25/2020
Special inspection requirement — Energy Code Compliance Inspections
Steve Chon
11/25/2020
Special inspection requirement — HVAC and service water heating equipment
Steve Chon
11/25/2020
Special inspection requirement — HVAC and service water heating system controls
Steve Chon
11/25/2020
Special inspection requirement — HVAC insulation and sealing
Steve Chon
04/06/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/06/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/11/2013
Violation issued (ECB, closed)
Construction
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/22/2000
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
02/22/2000
Violation issued (ECB, closed)
Construction
02/22/2000
Violation issued (ECB, closed)
Construction
02/22/2000
Violation issued (ECB, closed)
Construction
02/22/2000
Violation issued (ECB, closed)
Construction
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/14/1994
Violation issued (ECB, closed)
Local Law
05/03/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/26/1988
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedI DO PLUMBING & HTG INC09/29/2026
DOB NOWMechanical SystemsSigned-offTREND 21 MANAGEMENT INC11/30/2020
BISOTISSUEDTREND 21 MANAGEMENT INC06/30/2015
BISOTISSUEDTREND 21 MANAGEMENT INC02/26/2015
BISPLISSUEDI DO PLUMBING & HTG INC02/26/2015
BISPLISSUEDJ.G. PLUMBING & HTNG CORP08/10/2010
BISFPISSUEDLUND FIRE PRODUCTS CO INC02/05/2009
BISFPISSUEDIDEAL FIRE SYSTEMS INC09/30/2002
BISOTISSUEDTELETEMP04/09/2002
BISPLISSUEDTRADELINE PLUMBING INC04/09/2002
BISMHISSUEDTELETEMP04/08/2002
BISOTISSUEDRECEPTION HOUSE REALTY ASSOC.LIC07/25/2000
1 project · most recent 11/25/2020
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/25/2020Signed-offTREND 21 MANAGEMENT INCVentilation Systems
Cooling
Carrier 48TCED16ACA50A0A0 15 tons · Rooftop Unit ×1
Heating
Carrier 48TCED16ACA50A0A0 15 tons · Rooftop Unit ×1
Ventilation
Carrier 48TCED16ACA50A0A0 15 tons · Rooftop Unit ×1
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
11/25/2020Mechanical SystemsSteve Chonspecial
11/25/2020FinalSteve Chonprogress
11/25/2020Energy Code Compliance InspectionsSteve Chonprogress
11/25/2020HVAC and service water heating equipment Steve Chonenergy_progress
11/25/2020HVAC and service water heating system controls Steve Chonenergy_progress
11/25/2020HVAC insulation and sealing Steve Chonenergy_progress
▾Documents — 51 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/27/2026Q00433338-I1Request digital key ↗
▸Applications & Permits10
▸BISWORK PERMIT APPLICATION4
03/21/2015421071841Open ↗
03/21/2015421071841Open ↗
08/18/2010410201455Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION4
04/17/2015421071841Open ↗
02/17/2015421071841Open ↗
01/24/2015421071841Open ↗
Showing 3 of 4 on file for this type
▸BISPLACE OF ASSEMBLY1
03/03/2009410230940Open ↗
▸BISPLACE OF ASSEMBLY APPLICATION1
04/25/2012410230940Open ↗
▸Seals & Professional Certifications12
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
03/21/2015421071841Open ↗
01/24/2015421071841Open ↗
04/25/2012410230940Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/28/2026Q00433338-I1Open ↗
08/28/2026Q00433338-I1Open ↗
08/28/2026Q00433338-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/27/2026Q00433338-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026Q00433338-I1Open ↗
▸Trade Schedules & Equipment6
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
04/17/2015421071841Open ↗
02/17/2015421071841Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
05/07/2015421071841Open ↗
10/01/2010410201455Open ↗
▸BISDETECTOR:SMOKE-CERTIFICATE OF INSTALLATION1
04/25/2012410230940Open ↗
▸BISSCHEDULE B - PLUMBING1
01/15/2009410201455Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
01/24/2015421071841Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
01/15/2009410201455Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
03/21/2015421071841Open ↗
01/24/2015421071841Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00433338-I1Open ↗
▸Approvals, Objections & Sign-offs7
▸BISLETTERS - SUPPORTING DOCUMENTATION3
04/25/2012410230940Open ↗
04/25/2012410230940Open ↗
06/21/2011410201455Open ↗
▸BISADMINISTRATIVE OBJECTIONS3
01/24/2015421071841Open ↗
03/03/2009410230940Open ↗
12/05/2008410201455Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
06/21/2011410201455Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT4
03/20/2015421071841Open ↗
01/24/2015421071841Open ↗
06/21/2011410201455Open ↗
Showing 3 of 4 on file for this type
▸BISLL58/88-CIVIL PENALTY AFFIDAVIT1
02/05/2009410201455Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
04/25/2015421071841Open ↗
12/07/2011410230940Open ↗
▸BISEFILING COVER SHEET1
01/24/2015421071841Open ↗
▸Other Documents2
▸BISFIRE SUPP ANSUL APPROVL- FD-FSS2
06/21/2011410201455Open ↗
10/01/2010410201455Open ↗