← Back
City residence, one family
167 EAST 80 STREET
MANHATTAN · Upper East Side-Carnegie Hill · BIN 1047515
💬 Discuss this project
1899Year Built
3Stories
A4Building Class
R8BZoning
3,200 sfGross Floor Area
1Units
City residence, one family · 1,667 sf lot · 1.92 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalGeneralOther
Permit Issued — active, not yet Signed-off
Floor 1Under Construction1 filing
Site & exteriorUnder Construction1 filing · 3 docs
Filed — no permit issued40p · 1 filing · 13 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LIYANA CONSTRUCTION109/10/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/15/2024$6.8M—Private party → Private party$2,109/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KEVIN GALLEN PE LLC105/20/2026
SEVERUD ASSOCIATES105/19/2026
TURETT COLLABORATIVE ARCHITECTS105/18/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LIYANA CONSTRUCTION INCGeneral Contractor109/10/2026
Building Lifecycle
All (27)Filed (3)Permit Issued (2)Objection (12)Special Inspection (10)
09/09/2026
Permit issued — General Construction
M01454476-I1-GC
09/02/2026
Permit issued — Sidewalk Shed
M01449614-I1-SH
05/28/2026
Objection resolved — Addressed
05/26/2026
Objection raised — Cost
05/26/2026
Objection resolved — Addressed
05/26/2026
Objection resolved — Addressed
05/26/2026
Objection resolved — Addressed
05/26/2026
Objection resolved — Addressed
05/26/2026
Objection resolved — Addressed
05/21/2026
Objection raised — Scope
05/21/2026
Objection raised — Other
05/21/2026
Objection raised — Other
05/20/2026
Filed — Alteration
HORIZONTAL ENLARGEMENT OF PRIOR-TO-1968 BC CLASS 3NFP, 3-STORY + BASEMENT & CELLAR SINGLE FAMILY HOME; FILED FOR REVIEW AS 1968 BC CLASS II-B, 3-STORY + BASEMENT & CELLAR, SINGLE-FAMILY HOME;RENOVATIONS & ADDITIONS AS PER PLANS FILED HEREWITH.
M01382179-S1
05/20/2026
Objection raised — Other
05/20/2026
Objection raised — Other
05/19/2026
Filed — Alteration
HORIZONTAL ENLARGEMENT OF PRIOR-TO-1968 BC CLASS 3NFP, 3-STORY + BASEMENT & CELLAR SINGLE FAMILY HOME; FILED FOR REVIEW AS 1968 BC CLASS II-B, 3-STORY + BASEMENT & CELLAR, SINGLE-FAMILY HOME;RENOVATIONS & ADDITIONS AS PER PLANS FILED HEREWITH.
M01382179-S2
05/18/2026
Filed — Alteration
HORIZONTAL ENLARGEMENT OF PRIOR-TO-1968 BC CLASS 3NFP, 3-STORY + BASEMENT & CELLAR SINGLE FAMILY HOME; FILED FOR REVIEW AS 1968 BC CLASS II-B, 3-STORY + BASEMENT & CELLAR, SINGLE-FAMILY HOME;RENOVATIONS & ADDITIONS AS PER PLANS FILED HEREWITH.
M01382179-I1
05/14/2026
Special inspection requirement — Lighting in dwelling units
05/14/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
05/14/2026
Special inspection requirement — Fire-Resistance Rated Construction
05/14/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/14/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
05/14/2026
Special inspection requirement — Air barrier - visual inspection
05/14/2026
Special inspection requirement — Fenestration air leakage
05/14/2026
Special inspection requirement — Fenestration areas
05/14/2026
Special inspection requirement — Insulation placement and R values
04/02/2026
Special inspection requirement — Final
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedLIYANA CONSTRUCTION INC09/09/2026
DOB NOWSidewalk ShedPermit IssuedSAFELINE GROUP INC09/02/2026
BISPLISSUEDAMOK INC06/26/1995
BISOTISSUEDCN RENOVATION CO INC06/09/1995
1 project · most recent 05/20/2026
Others
FiledStatusContractorScopeMake / Model / Capacity
05/20/2026——Others
Other
N/A n/a 175 CFM · Ductwork ×2
2 projects · most recent 09/02/2026
FiledStatusContractorScope
09/02/2026Permit IssuedRICHARD NEU—
07/16/2026CompleteCRESCO ELECTRICAL CORP—
1 project · most recent 05/20/2026
Steel Concrete Masonry
FiledStatusContractorScope
05/20/2026——Steel, Concrete, Masonry
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
05/14/2026Lighting in dwelling units—energy_progress
05/14/2026Structural Stability – Alterations of existing buildings—special
05/14/2026Fire-Resistance Rated Construction—progress
05/14/2026Fire-Resistant Penetrations and Joints—special
05/14/2026Fenestration and door U-factor and product ratings—energy_progress
05/14/2026Air barrier - visual inspection—energy_progress
05/14/2026Fenestration air leakage—energy_progress
05/14/2026Fenestration areas—energy_progress
05/14/2026Insulation placement and R values—energy_progress
04/02/2026Final—progress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/17/2026M01382179-S3Request digital key ↗
08/15/2026M01382179-I1Request digital key ↗
08/15/2026M01382179-S2Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/15/2026M01382179-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026M01382179-I1Open ↗
08/17/2026M01382179-S1Open ↗
08/17/2026M01382179-S2Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/17/2026M01382179-S3Open ↗
08/15/2026M01382179-I1Open ↗
08/15/2026M01382179-S2Open ↗
Showing 3 of 4 on file for this type
▸Other Documents4
▸DOB NOWPlot Diagram2
08/17/2026M01382179-S3Open ↗
08/15/2026M01382179-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/15/2026M01382179-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/15/2026M01382179-I1Open ↗