← Back
Three families
167 PROSPECT PLACE
BROOKLYN · BIN 3028464
💬 Discuss this project
1871Year Built
3Stories
C0Building Class
R6BZoning
3,760 sfGross Floor Area
3Units
Rent Stabilized3 Open Violations ▸FDNY Report ↗
Three families · Owner of record: SHOREVIEW CAPITAL LLC · 2,620 sf lot · 1.44 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
Floor 3Under Construction10p · 3 filings · 20 docs
Floor 2Under Construction10p · 3 filings · 20 docs
Floor 1Under Construction10p · 3 filings · 20 docs
CellarUnder Construction13p · 3 filings · 20 docs
Basement4p · 1 filing · 8 docs
Sub-BasementUnder Construction5p · 2 filings · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SHOREVIEW CAPITAL LLC303/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/29/2022$2.5M—U.S. BANK NATIONAL ASSOCIATION AS INDENTURE TRUSTE → SHOREVIEW CAPITAL LLC$673/sf building
06/15/2022$2.7M—— → —$728/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
L&C ASSOCIATES306/01/2023
L & C ASSOCIATES102/02/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
L&C ASSOCIATES403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A & S CONTRACTORS OF NY IGeneral Contractor807/08/2026
TRINCITY ELECTRIC, INCElectrical103/22/2026
DYNAMIC PLBNG & SPRKR CORFire Protection107/08/2026
HORBRIDGE PLUMBING & HEATINGPlumbing107/08/2026
M & M PIPING AND HEATINGPlumbing108/13/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
IP CONCRETE TESTING AND I6252205/19/2023
Building Lifecycle
All (45)Filed (4)Permit Issued (9)Violation (24)Inspection (8)
08/12/2026
Permit issued — Plumbing
B00826127-I1-PL
03/17/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
11/07/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/07/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/19/2025
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)
Certified
View inspection ↗
08/04/2025
Permit issued — General Construction
B00802786-I1-GC
06/12/2025
Permit issued — Construction Fence
B00881862-I1-FN
06/10/2025
Violation issued (HPD, closed)
A
11/29/2024
Violation issued (HPD, closed)
I
06/05/2024
Permit issued — Construction Fence
B00881862-I1-FN
05/28/2024
Permit issued — General Construction
B00802786-I1-GC
04/11/2024
Violation issued (HPD, closed)
A
01/30/2024
Violation issued (ECB, closed)
Construction
11/22/2023
Violation issued (HPD, closed)
I
09/22/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/22/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/22/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/20/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/08/2023
Permit issued — Sprinklers
B00873250-I1-EW-SP
06/28/2023
Permit issued — Plumbing
B00826127-I1-PL
06/08/2023
Permit issued — Construction Fence
B00881862-I1-FN
06/01/2023
Filed — Alteration
INSTALL TEMPORARY CONSTRUCTION FENCE FOR ALT FILED UNDER DOB# B00802786-I1
B00881862-I1
05/25/2023
Permit issued — General Construction
B00802786-I1-GC
05/19/2023
Filed — Alteration
PROVIDE NEW FIRE SPRINKLER SYSTEM IN CONJUNCTION W/ALTERATION 1 APPLICATION #B00802786-I1, CONVERTING EXISTING THREE(3) DWELLING UNITS TO TWO(2) DWELLING UNITS. PROPOSE ONLY INTERIOR RENOVATION WITH PARTITIONS.
B00873250-I1
05/19/2023
Filed — Alteration
FILING FOR PLUMBING WORK TYPE IN CONJUNCTION WITH ALT 1 JOB# B00802786-I1, INTERIOR RENOVATION WITH PARTITIONS. OBTAIN NEW CO
B00826127-I1
03/24/2023
Violation issued (HPD, closed)
A
02/02/2023
Filed — Alteration CO
B00802786-I1
11/14/2022
Violation issued (HPD, closed)
I
03/01/2022
Violation issued (HPD, closed)
A
03/01/2022
Violation issued (HPD, closed)
I
04/12/2021
Violation issued (HPD, closed)
A
10/31/2019
Violation issued (HPD, closed)
I
11/02/2018
Violation issued (FDNY_NOV, closed)
10/19/2018
Violation issued (HPD, closed)
I
05/02/2018
Violation issued (FDNY_NOV, closed)
01/12/2018
Violation issued (HPD, open)
C
11/28/2017
Violation issued (HPD, closed)
I
11/04/2017
Violation issued (FDNY_NOV, closed)
11/14/2016
Violation issued (HPD, closed)
I
10/13/2015
Violation issued (HPD, closed)
I
02/24/2015
Violation issued (HPD, closed)
I
12/14/1987
Violation issued (FDNY_NOV, closed)
10/13/1982
Violation issued (HPD, open)
A
10/13/1982
Violation issued (HPD, open)
A
01/20/1982
Violation issued (HPD, closed)
A
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedM & M PIPING AND HEATING08/12/2026
DOB NOWGeneral ConstructionPermit IssuedA S CONTRACTORS OF NY I08/04/2025
DOB NOWConstruction FencePermit IssuedA S CONTRACTORS OF NY I06/12/2025
DOB NOWConstruction FencePermit IssuedA S CONTRACTORS OF NY I06/05/2024
DOB NOWGeneral ConstructionPermit IssuedA S CONTRACTORS OF NY I05/28/2024
DOB NOWSprinklersPermit IssuedCITYWIDE PLBG, HTG &SPRKL08/08/2023
DOB NOWPlumbingPermit IssuedHORBRIDGE PLUMBING & HEAT06/28/2023
DOB NOWConstruction FencePermit IssuedA S CONTRACTORS OF NY I06/08/2023
DOB NOWGeneral ConstructionPermit IssuedA S CONTRACTORS OF NY I05/25/2023
BISBLISSUEDWHALECO FUEL CORP04/05/1993
1 project · most recent 05/19/2023
FiledStatusContractorScope
05/19/2023Permit IssuedDYNAMIC PLBNG & SPRKR COR34 heads
2 projects · most recent 05/19/2023
Gas Water/Sanitary
FiledStatusContractorScope
05/19/2023———
05/19/2023Permit IssuedM & M PIPING AND HEATINGGas, Water/Sanitary
1 project · most recent 05/26/2023
General Wiring
FiledStatusContractorScope
05/26/2023Permit IssuedTRINCITY ELECTRIC, INCGeneral Wiring
1 project · most recent 06/01/2023
Fence
FiledStatusContractorScope
06/01/2023Permit IssuedA & S CONTRACTORS OF NY IFence
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
03/17/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/07/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/07/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/19/2025Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
09/22/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/22/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/22/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
09/20/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/10/2023Sprinkler SystemsINDARDEO PARBHUNATHspecial
02/20/2023Energy Code Compliance InspectionsINDARDEO PARBHUNATHprogress
02/20/2023HVAC-R and service water heating system controlsINDARDEO PARBHUNATHenergy_progress
02/20/2023HVAC-R and service water piping design and insulationINDARDEO PARBHUNATHenergy_progress
02/20/2023HVAC-R and service water heating equipmentINDARDEO PARBHUNATHenergy_progress
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026B00802786-I1Request digital key ↗
08/27/2026B00826127-I1Request digital key ↗
08/27/2026B00873250-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits2
▸DOB NOWLPC Approval/Permit2
08/13/2026B00802786-I1Open ↗
08/13/2026B00826127-I1Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B00802786-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00802786-I1Open ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature4
08/31/2026B00826127-I1Open ↗
08/31/2026B00826127-I1Open ↗
08/31/2026B00826127-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026B00802786-I1Open ↗
08/27/2026B00826127-I1Open ↗
08/27/2026B00881862-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026B00873250-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/27/2026B00802786-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/27/2026B00802786-I1Open ↗
08/27/2026B00826127-I1Open ↗
08/13/2026B00873250-I1Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/27/2026B00802786-I1Open ↗