← Back
Two family converted from one family
1671 84 STREET
BROOKLYN · BIN 3164532
💬 Discuss this project
1940Year Built
2Stories
B3Building Class
R5Zoning
1,300 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 980 sf lot · 1.33 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 21p · 1 filing · 16 docs
Floor 1
Basement1p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
M J DESIGN BUILD1203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/11/2023$880K—— → Private party$677/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
M-CON ENGINEERING, PC303/12/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
M J DESIGN BUILD603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
M J DESIGN AND BUILD INCGeneral Contractor303/21/2026
KJK ELECTRIC INCElectrical103/22/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M-CON ENGINEERING7341303/12/2024
Building Lifecycle
All (14)Filed (3)Permit Issued (2)Signed Off (2)Violation (1)Inspection (6)
04/15/2024
Signed off — Alteration
RENOVATION ON BASEMENT, 1ST AND 2ND FLOOR, PARTITION WORK AS PER PLAN. PLUMBING WORK TYPE WILL FILE SEPARATELY. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00954178-I1
04/15/2024
Signed off — Alteration
FILING PLUMBING WORK TYPE IN CONJUNCTION WITH JOB#B00954178, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00954207-I1
04/12/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/10/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/10/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/09/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
04/08/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/12/2024
Filed — Alteration
RENOVATION ON BASEMENT, 1ST AND 2ND FLOOR, PARTITION WORK AS PER PLAN. PLUMBING WORK TYPE WILL FILE SEPARATELY. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00954178-P1
01/11/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/02/2023
Permit issued — Plumbing
B00954207-I1-PL
10/31/2023
Permit issued — General Construction
B00954178-I1-GC
10/30/2023
Filed — Alteration
RENOVATION ON BASEMENT, 1ST AND 2ND FLOOR, PARTITION WORK AS PER PLAN. PLUMBING WORK TYPE WILL FILE SEPARATELY. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00954178-I1
10/30/2023
Filed — Alteration
FILING PLUMBING WORK TYPE IN CONJUNCTION WITH JOB#B00954178, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00954207-I1
08/17/2018
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.11/02/2023
DOB NOWGeneral ConstructionSigned-offM J DESIGN AND BUILD INC10/31/2023
1 project · most recent 11/07/2023
General Wiring
FiledStatusContractorScope
11/07/2023CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
04/12/2024Pass-Final General Construction Non-Directive 14PassView ↗
04/10/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/10/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/09/2024Fail-Final General Construction Non-Directive 14FailView ↗
04/08/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/11/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
03/12/2024Air barrier - visual inspectionMichelle Contrienergy_progress
03/12/2024Fire-Resistant Penetrations and JointsMichelle Contrispecial
03/12/2024Fire-Resistance Rated ConstructionMichelle Contriprogress
03/12/2024Energy Code Compliance InspectionsMichelle Contriprogress
03/12/2024Fenestration air leakageMichelle Contrienergy_progress
03/01/2024Fire-Resistant Penetrations and JointsMichelle Contrispecial
03/01/2024Energy Code Compliance InspectionsMichelle Contriprogress
03/01/2024Fire-Resistance Rated ConstructionMichelle Contriprogress
03/01/2024Air barrier - visual inspectionMichelle Contrienergy_progress
03/01/2024Fenestration air leakageMichelle Contrienergy_progress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/26/2026B00954178-P1Request digital key ↗
08/26/2026B00954178-I1Request digital key ↗
08/26/2026B00954207-I1Request digital key ↗
▸Seals & Professional Certifications13
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026B00954178-I1Open ↗
09/01/2026B00954178-I1Open ↗
09/01/2026B00954178-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/26/2026B00954178-P1Open ↗
08/26/2026B00954178-I1Open ↗
08/13/2026B00954207-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B00954178-I1Open ↗
08/30/2026B00954178-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/26/2026B00954178-P1Open ↗
08/26/2026B00954178-I1Open ↗
08/13/2026B00954207-I1Open ↗