← Back
Three families
1679 WEST 7 STREET
BROOKLYN · Gravesend (West) · BIN 3175534
💬 Discuss this project
1935Year Built
2Stories
C0Building Class
R7AZoning
2,560 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Three families · 2,500 sf lot · 1.02 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingGeneral
Floor 23p · 1 filing · 9 docs
Floor 15p · 2 filings · 15 docs
Basement6p · 2 filings · 15 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/24/2022$1.5M—— → —$602/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
G ENGINEERING PC601/18/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SPLEN CONSTRUCTION INCGeneral Contractor303/21/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
G ENGINEERING PC7778301/18/2023
Building Lifecycle
All (22)Filed (6)Permit Issued (2)Signed Off (2)Violation (5)Inspection (4)Special Inspection (3)
02/22/2023
Signed off — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILERS AND HOT WATER HEATERS ON BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08002422-I1
02/22/2023
Signed off — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08002418-I1
02/21/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
01/18/2023
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILERS AND HOT WATER HEATERS ON BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08002422-P2
01/18/2023
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08002418-P2
11/16/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
11/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/10/2022
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILERS AND HOT WATER HEATERS ON BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08002422-P1
09/26/2022
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08002418-P1
09/26/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIONGCAI GU
09/26/2022
Special inspection requirement — Energy Code Compliance Inspections
XIONGCAI GU
09/26/2022
Special inspection requirement — Fire-Resistance Rated Construction
XIONGCAI GU
09/20/2022
Permit issued — Plumbing
B08002422-I1-PL
09/16/2022
Permit issued — General Construction
B08002418-I1-GC
09/15/2022
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILERS AND HOT WATER HEATERS ON BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08002422-I1
09/15/2022
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08002418-I1
03/02/2022
Violation issued (HPD, closed)
A
03/02/2022
Violation issued (HPD, closed)
I
04/13/2021
Violation issued (HPD, closed)
A
10/31/2019
Violation issued (HPD, closed)
I
10/14/2015
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC09/20/2022
DOB NOWGeneral ConstructionSigned-offSPLEN CONSTRUCTION INC09/16/2022
1 project · most recent 09/20/2022
General Wiring
FiledStatusContractorScope
09/20/2022CompleteA.C. MORGAN ELECTRICGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
02/21/2023Pass-Final General Construction Non-Directive 14PassView ↗
11/16/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
11/16/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/16/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
09/26/2022Fire-Resistant Penetrations and JointsXIONGCAI GUspecial
09/26/2022Energy Code Compliance InspectionsXIONGCAI GUprogress
09/26/2022Fire-Resistance Rated ConstructionXIONGCAI GUprogress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/28/2026B08002422-I1Request digital key ↗
08/28/2026B08002422-P1Request digital key ↗
08/28/2026B08002422-P2Request digital key ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/28/2026B08002422-P1Open ↗
08/28/2026B08002422-I1Open ↗
08/28/2026B08002418-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026B08002418-P1Open ↗
08/25/2026B08002418-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026B08002418-P1Open ↗