| Firm | Filings | Most Recent |
|---|---|---|
| RAND ENGINEERING & ARCHITECTURE DPC | 12 | 02/09/2024 |
| NICHOLAS J. DEFELICE, P.E. | 4 | 04/25/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| JULIAN A. GOMEZ | 24 | 03/21/2026 |
| CH BUILDING CONSULTANTS | 8 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| CENTRAL CONSTRUCTION MANAGEMENT | General Contractor | 16 | 07/08/2026 |
| ZATOS PLBG AND HTG INC | Plumbing | 2 | 07/08/2026 |
| DISALVO CONTRACTING | General Contractor | 1 | 06/28/2026 |
| V. DISALVO CONTRACTING CO | General Contractor | 1 | 04/09/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| RAND ENGINEERING & ARCHIT | 266 | 11 | 02/09/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | DISALVO CONTRACTING LLC | 06/26/2026 |
| DOB NOW | General Construction | Permit Issued | V. DISALVO CONTRACTING CO | 02/26/2026 |
| DOB NOW | Plumbing | Signed-off | ZATOS PLBG AND HTG INC | 08/30/2023 |
| DOB NOW | General Construction | Permit Issued | CENTRAL CONSTRUCTION MANAGEMENT | 08/29/2023 |
| DOB NOW | General Construction | Permit Issued | CENTRAL CONSTRUCTION MANAGEMENT | 08/29/2023 |
| DOB NOW | Structural | Permit Issued | CENTRAL CONSTRUCTION MANAGEMENT | 08/29/2023 |
| DOB NOW | Structural | Permit Issued | CENTRAL CONSTRUCTION MANAGEMENT | 07/19/2023 |
| DOB NOW | Mechanical Systems | Permit Issued | CENTRAL CONSTRUCTION MANAGEMENT | 05/01/2023 |
| DOB NOW | General Construction | Permit Issued | CENTRAL CONSTRUCTION MANAGEMENT | 03/27/2023 |
| DOB NOW | Plumbing | Signed-off | ZATOS PLBG AND HTG INC | 08/05/2022 |
| DOB NOW | Structural | Permit Issued | CENTRAL CONSTRUCTION MANAGEMENT | 07/29/2022 |
| DOB NOW | Mechanical Systems | Permit Issued | CENTRAL CONSTRUCTION MANAGEMENT | 05/13/2022 |
| DOB NOW | General Construction | Permit Issued | CENTRAL CONSTRUCTION MANAGEMENT | 03/22/2022 |
| DOB NOW | Supported Scaffold | Permit Issued | CENTRAL CONSTRUCTION MANAGEMENT | 02/01/2022 |
| DOB NOW | Sidewalk Shed | Permit Issued | CENTRAL CONSTRUCTION MANAGEMENT | 02/01/2022 |
| BIS | EQ | ISSUED | ROCKLEDGE SCAFFOLD CORP | 07/12/1999 |
| BIS | OT | ISSUED | HORN MAINTENANCE CORP | 07/02/1993 |
| BIS | EQ | ISSUED | REGIONAL SCAFFOLD EQUIPMENT CORP | 08/31/1992 |
| BIS | EQ | ISSUED | REGIONAL SCAFFOLD EQUIPMENT CORP | 08/24/1992 |
| BIS | EQ | ISSUED | REGIONAL SCAFFOLD EQUIPMENT CORP | 04/20/1992 |
| BIS | EQ | ISSUED | REGIONAL SCAFFOLD EQUIPMENT CORP | 04/20/1992 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 03/22/2022 | Permit Issued | CENTRAL CONSTRUCTION MANA | Air Conditioning Systems | Cooling Mitsubishi Electric PEFY-P18NMAU-E3 18,000 BTU · Vrf Indoor ×14 PEFY-P30NMAU-E3 30,000 BTU · Vrf Indoor ×10 PKFY-P12NLMU-E 12,000 BTU · Vrf Indoor ×8 PKFY-P12NHMU-E2 12,000 BTU · Vrf Indoor ×6 PFFY-P18NRMU-E 18,000 BTU · Vrf Indoor ×4 PKFY-P24NKMU-E 24,000 BTU · Vrf Indoor ×4 PUMY-HP48NKMU 48,000 BTU · Vrf Outdoor ×4 PVFY-P48NAMU-E 48,000 BTU · Vrf Indoor ×4 PEFY-P12NMAU-E3 12,000 BTU · Vrf Indoor ×2 PKA-A12HA7 12,000 BTU · Split System ×2 PKFY-P08NLMU-E 8,000 BTU · Vrf Indoor ×2 PKFY-P18NHMU-E2 18,000 BTU · Vrf Indoor ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/09/2024 | Signed-off | ZATOS PLBG AND HTG INC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/31/2022 | Permit Issued | TOP SHELF ELECTRIC CORP | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/07/2023 | Permit Issued | CENTRAL CONSTRUCTION MANA | Steel, Concrete |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/13/2022 | Permit Issued | CENTRAL CONSTRUCTION MANA | Sidewalk Shed |
| Date | Type | Result | Report |
|---|---|---|---|
| 09/23/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 09/16/2025 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 06/16/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 02/15/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 12/26/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 09/06/2023 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 02/12/2024 | Fire-Resistant Penetrations and Joints | Peter Varsalona | special |
| 02/12/2024 | HVAC-R and service water heating system controls | Raymond Locicero | energy_progress |
| 02/12/2024 | HVAC-R and service water piping design and insulation | Raymond Locicero | energy_progress |
| 02/12/2024 | Maintenance information | Raymond Locicero | energy_progress |
| 02/12/2024 | HVAC-R and service water heating equipment | Raymond Locicero | energy_progress |
| 02/12/2024 | Energy Code Compliance Inspections | Raymond Locicero | progress |
| 02/05/2024 | HVAC-R and service water heating equipment | Raymond Locicero | energy_progress |
| 02/05/2024 | HVAC-R and service water heating system controls | Raymond Locicero | energy_progress |
| 02/05/2024 | HVAC-R and service water piping design and insulation | Raymond Locicero | energy_progress |
| 02/05/2024 | Fire-Resistant Penetrations and Joints | Peter Varsalona | special |
| 02/05/2024 | Energy Code Compliance Inspections | Raymond Locicero | progress |
| 02/05/2024 | Maintenance information | Raymond Locicero | energy_progress |
| 12/01/2023 | Fire-Resistant Penetrations and Joints | Peter Varsalona | special |
| 12/01/2023 | Maintenance information | Raymond Locicero | energy_progress |
| 12/01/2023 | HVAC-R and service water heating equipment | Raymond Locicero | energy_progress |
| 12/01/2023 | HVAC-R and service water piping design and insulation | Raymond Locicero | energy_progress |
| 12/01/2023 | HVAC-R and service water heating system controls | Raymond Locicero | energy_progress |
| 12/01/2023 | Energy Code Compliance Inspections | Raymond Locicero | progress |
| 02/08/2023 | Concrete - Cast-In-Place | James Vignola | special |
| 02/08/2023 | Structural Steel - High Strength Bolting | James Vignola | special |
| 02/08/2023 | Masonry | James Vignola | special |
| 02/08/2023 | Structural Steel - Welding | James Vignola | special |
| 02/08/2023 | Sprayed fire-resistant materials | James Vignola | special |
| 02/08/2023 | Structural Stability – Alterations of existing buildings | James Vignola | special |
| 02/08/2023 | Final | James Vignola | progress |