← Back
Predominantly retail with other uses
1683 PITKIN AVENUE
BROOKLYN · BIN 3326584
💬 Discuss this project
1930Year Built
3Stories
K4Building Class
C4-3Zoning
12,421 sfGross Floor Area
3Units
0 Open ViolationsFDNY Report ↗
Predominantly retail with other uses · Owner of record: 1681 PITKIN PARTNERS LLC · 4,893 sf lot · 2.54 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction36p · 3 filings · 20 docs
Floor 3Under Construction35p · 2 filings · 20 docs
Floor 2Under Construction38p · 2 filings · 20 docs
Floor 1Under Construction37p · 3 filings · 20 docs
CellarUnder Construction33p · 4 filings · 20 docs
1 job · most recent 06/11/2025
Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/11/2025Permit IssuedBBM CONSTRUCTION CORPHeating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-3C24NA2-U1 22,000 BTU · Heat Pump Outdoor ×5
MUZ-GL15NA 14,000 BTU · Heat Pump Outdoor ×4
MXZ-4C36NA2-U1 35,400 BTU · Heat Pump Outdoor ×1
MXZ-5C42NA2-U1 40,500 BTU · Heat Pump Outdoor ×1
Heating
Panasonic E3323TD-RP 5,120 BTU · Electric Heater ×1
Ventilation
Greenheck CSP-A390-VG 300 CFM · Exhaust Fan ×1
2 jobs · most recent 07/10/2025
Sprinkler System
FiledStatusContractorScope
07/10/2025Signed-offMETFLOW FIRE CONTROL LLC86 heads
06/11/2025Permit IssuedMETFLOW FIRE CONTROL LLCSprinkler System
1 job · most recent 06/11/2025
Water/Sanitary
FiledStatusContractorScope
06/11/2025Permit IssuedMETFLOW MECHANICAL LLCWater/Sanitary
7 jobs · most recent 11/07/2025
General Wiring
FiledStatusContractorScope
11/07/2025CompleteRAINBOW ELECTRIC CO., INC—
11/07/2025CompleteRAINBOW ELECTRIC CO., INC—
11/07/2025CompleteRAINBOW ELECTRIC CO., INC—
09/10/2025CompleteEMPIRE STATE ECT'L CON INGeneral Wiring
07/29/2025CompleteS&R ELECTRICAL & MECHANICGeneral Wiring
07/08/2025Permit IssuedS&R ELECTRICAL & MECHANICGeneral Wiring
02/10/2025Permit IssuedS&R ELECTRICAL & MECHANIC—
1 job · most recent 07/10/2025
Fence
FiledStatusContractorScope
07/10/2025Signed-offBBM CONSTRUCTION CORPFence
Building Lifecycle
All (142)Filed (23)Permit Issued (18)Signed Off (7)Violation (17)Inspection (12)Objection (35)Special Inspection (30)
08/04/2026
Signed off — Alteration
INSTALL EXTERIOR ILLUMINATED D/F BLADE SIGN (CHIPOTLE )
B01186529-I1
04/16/2026
Signed off — Alteration
Related Plumbing work for Chipotle tenant build out at first floor
B01219535-S2
04/15/2026
Signed off — Alteration
Related Plumbing work for Chipotle tenant build out at first floor
B01219535-S1
04/15/2026
Signed off — Alteration
Related Plumbing work for Chipotle tenant build out at first floor
B01219535-I1
04/10/2026
Signed off — Alteration
Related Plumbing work for Chipotle tenant build out at first floor
B01219535-S3
04/08/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/30/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/16/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
01/13/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/13/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
01/02/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/15/2025
Signed off — Alteration
INSTALL EXTERIOR ILLUMINATED D/F BLADE SIGN (LOGO)
B01186500-I1
12/12/2025
Permit issued — Structural
B01145391-I1-ST
12/11/2025
Signed off — Alteration
INSTALL EXTERIOR ILLUMINATED WALL SIGN (CHIPOTLE )
B01186540-I1
12/11/2025
Permit issued — General Construction
B01134941-I1-GC
11/12/2025
Filed — Alteration
Related Plumbing work for Chipotle tenant build out at first floor
B01219535-P1
11/06/2025
Filed — Alteration
INSTALL EXTERIOR ILLUMINATED WALL SIGN (CHIPOTLE )
B01186540-P1
11/06/2025
Special inspection requirement — Final
LEON SKVIRSKY
10/28/2025
Permit issued — Sprinklers
B01219535-S3-EW-SP
10/14/2025
Special inspection requirement — Final
LEON SKVIRSKY
10/13/2025
Filed — Alteration
Related Plumbing work for Chipotle tenant build out at first floor
B01219535-S3
10/08/2025
Special inspection requirement — Sprinkler Systems
steven Giammona
09/24/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/10/2025
Objection resolved — Addressed
09/09/2025
Permit issued — Mechanical Systems
B01207333-S2-MS
09/09/2025
Objection resolved — Addressed
09/09/2025
Objection resolved — Addressed
08/28/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/28/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/21/2025
Permit issued — Sign
B01186529-I1-SG
08/21/2025
Permit issued — Mechanical Systems
B01219535-S2-MS
08/21/2025
Permit issued — Sign
B01186500-I1-SG
08/21/2025
Permit issued — Plumbing
B01219535-S1-PL
08/21/2025
Permit issued — General Construction
B01219535-I1-GC
08/21/2025
Permit issued — Sign
B01186540-I1-SG
08/19/2025
Filed — Alteration
INSTALL EXTERIOR ILLUMINATED D/F BLADE SIGN (CHIPOTLE )
B01186529-I1
08/19/2025
Filed — Alteration
INSTALL EXTERIOR ILLUMINATED D/F BLADE SIGN (LOGO)
B01186500-I1
08/19/2025
Filed — Alteration
INSTALL EXTERIOR ILLUMINATED WALL SIGN (CHIPOTLE )
B01186540-I1
07/31/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
07/29/2025
Objection resolved — Addressed
07/29/2025
Objection resolved — Addressed
07/28/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/18/2025
Special inspection requirement — Permanent certificate
Paul Raymond
07/17/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/10/2025
Filed — Alteration
Sprinkler Systems filed in conjunction with Alt B01134941. Installation of New Sprinkler system including Sprinkler Heads for floors Cel, 1.
B01134941-P1
07/09/2025
Objection raised — Admin
07/09/2025
Objection resolved — Addressed
07/03/2025
Special inspection requirement — Sprinkler Systems
Paul Raymond
07/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
07/02/2025
Objection raised — Admin
07/02/2025
Objection raised — Scope
07/02/2025
Objection raised — Admin
07/01/2025
Permit issued — Plumbing
B01207333-S1-PL
06/26/2025
Permit issued — Construction Fence
B01134941-S3-FN
06/23/2025
Objection resolved — Addressed
06/23/2025
Objection resolved — Addressed
06/23/2025
Special inspection requirement — Duct leakage testing, insulation and design
Paul Raymond
06/12/2025
Objection resolved — Addressed
06/12/2025
Objection resolved — Addressed
06/12/2025
Objection resolved — Addressed
Latest 60 of 142 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MARCO REALTY ASSOCIATES4207/08/2026
1681 PITKIN PARTNERS LLC203/22/2026
OWNER OF 1681 PITKIN AVE103/22/2026
OWNER OF 1679 PITKIN AVEN103/22/2026
BBM CONSTRUCTION203/22/2026
CHESTER ROCKAWAY ASSOCIATES1803/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/06/2023$3.0M—— → —$242/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
WCW ENGINEERS INC311/12/2025
LEON SKVIRSKY PE411/06/2025
CCPE110/13/2025
ADVANCED ENGINEERING & INSPECTION,607/10/2025
DIEGO AGUILERA ARCHITECTS P.C.206/11/2025
DJLU ARCHITECT406/10/2025
LINGLE DESIGN GROUP, INC.105/20/2025
ELEVATED ENGINEERING NYC204/25/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BUILDING BROTHERS803/21/2026
SPEEDY EXPEDITING2803/21/2026
JUST ARCHITECTURE1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BBM CONSTRUCTION CORPGeneral Contractor607/08/2026
SOUTH EAST CONSTRUCTION GGeneral Contractor407/08/2026
SIGNSTAR NYCScaffold307/08/2026
CREATIVE PLUMBING INPlumbing307/08/2026
METFLOW FIRE CONTROL LLCFire Protection207/08/2026
S&R ELECTRICAL & MECHANICElectrical203/22/2026
HOWARD ZAMKOFFElectrical103/21/2026
ADVANCED PLBG LLCPlumbing107/08/2026
BENJAMIN DREBINElectrical103/21/2026
ADVANCED PLUMBING LLCFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SGM ENGINEERING2366511/12/2025
REGIONAL TESTING CORP.3941207/10/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedBBM CONSTRUCTION CORP12/12/2025
DOB NOWGeneral ConstructionSigned-offBBM CONSTRUCTION CORP12/11/2025
DOB NOWSprinklersSigned-offADVANCED PLUMBING LLC10/28/2025
DOB NOWMechanical SystemsPermit IssuedBBM CONSTRUCTION CORP09/09/2025
DOB NOWSignSigned-offSIGNSTAR NYC08/21/2025
DOB NOWMechanical SystemsSigned-offSOUTH EAST CONSTRUCTION G08/21/2025
DOB NOWSignSigned-offSIGNSTAR NYC08/21/2025
DOB NOWPlumbingSigned-offADVANCED PLBG LLC08/21/2025
DOB NOWGeneral ConstructionSigned-offSOUTH EAST CONSTRUCTION G08/21/2025
DOB NOWSignSigned-offSIGNSTAR NYC08/21/2025
DOB NOWPlumbingPermit IssuedAB PLUMBING INC07/01/2025
DOB NOWConstruction FencePermit IssuedBBM CONSTRUCTION CORP06/26/2025
DOB NOWPlumbingSigned-offAB PLUMBING INC06/10/2025
DOB NOWPlumbingPermit IssuedAB PLUMBING INC06/06/2025
DOB NOWSprinklersPermit IssuedMETFLOW FIRE CONTROL LLC06/06/2025
DOB NOWSprinklersSigned-offMETFLOW FIRE CONTROL LLC05/27/2025
DOB NOWGeneral ConstructionSigned-offBBM CONSTRUCTION CORP12/27/2024
DOB NOWStructuralPermit IssuedBBM CONSTRUCTION CORP12/26/2024
BISEQISSUEDSILVERCUP SCAFFOLDING 1 L08/03/2012
BISEQISSUEDSILVERCUP SCAFFOLDING 1 L08/03/2012
BISPLISSUEDAARON PLBG AND MECH SYST08/02/2012
BISOTISSUEDFPF CONSTRUCTION CORP07/30/2012
BISEQISSUEDFPF CONSTRUCTION CORP07/30/2012
BISMHISSUEDFPF CONSTRUCTION CORP07/30/2012
BISOTISSUEDFPF CONSTRUCTION CORP07/30/2012
BISOTISSUEDL.S. SIGN CO., INC07/18/2012
BIS—ISSUEDL.S. SIGN CO., INC07/18/2012
BISOTISSUEDY.O. COMMERCIAL CONSTRUCT07/10/2012
BISEQISSUEDY.O. COMMERCIAL CONSTRUCT07/10/2012
BISOTISSUEDY.O. COMMERCIAL CONSTRUCT07/09/2012
BISOTISSUEDY.O. COMMERCIAL CONSTRUCT07/09/2012
BISEQISSUEDY.O. COMMERCIAL CONSTRUCT07/09/2012
BISEQISSUEDY.O. COMMERCIAL CONSTRUCT07/09/2012
BISEQISSUEDY.O. COMMERCIAL CONSTRUCT05/15/2012
BISOTISSUEDY.O. COMMERCIAL CONSTRUCT05/15/2012
BISEQISSUEDY.O. COMMERCIAL CONSTRUCT04/20/2012
BISOTISSUEDY.O. COMMERCIAL CONSTRUCT04/20/2012
BISEQISSUEDY.O. COMMERCIAL CONSTRUCT04/09/2012
BISOTISSUEDY.O. COMMERCIAL CONSTRUCT04/09/2012
BISPLISSUEDTHEODORE WAGNER PLUMBING HEATING01/25/2001
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
04/08/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/30/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/16/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/13/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/13/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/02/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/24/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/28/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/28/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/31/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
07/28/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/17/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 86
DateRequirementInspectorRole
11/06/2025FinalLEON SKVIRSKYprogress
10/14/2025FinalLEON SKVIRSKYprogress
10/08/2025Sprinkler Systemssteven Giammonaspecial
07/18/2025Permanent certificatePaul Raymondenergy_progress
07/03/2025Fire-Resistant Penetrations and JointsPaul Raymondspecial
07/03/2025Sprinkler SystemsPaul Raymondspecial
06/23/2025Duct leakage testing, insulation and designPaul Raymondenergy_progress
06/05/2025Fire-Resistant Penetrations and JointsPaul Raymondspecial
06/04/2025Structural Stability – Alterations of existing buildings—special
06/04/2025Structural Stability – Alterations of existing buildingsPaul Raymondspecial
05/22/2025HVAC-R and service water heating system controlsPaul Raymondenergy_progress
05/22/2025Maintenance informationPaul Raymondenergy_progress
05/22/2025HVAC-R and service water heating equipmentPaul Raymondenergy_progress
05/22/2025HVAC-R and service water piping design and insulationPaul Raymondenergy_progress
05/16/2025Construction Operations Influencing Adjacent StructuresPaul Raymondspecial
05/16/2025MasonryPaul Raymondspecial
05/16/2025Structural Stability – Alterations of existing buildingsPaul Raymondspecial
05/16/2025Post-installed AnchorsPaul Raymondspecial
05/16/2025Structural Steel - WeldingPaul Raymondspecial
05/16/2025FinalPaul Raymondprogress
05/16/2025Structural Steel - High Strength BoltingPaul Raymondspecial
05/16/2025Structural Cold-Formed SteelPaul Raymondspecial
05/16/2025Structural Steel - DetailsPaul Raymondspecial
05/14/2025Fire-Resistant Penetrations and JointsPaul Raymondspecial
05/14/2025Energy Code Compliance InspectionsPaul Raymondprogress
Latest 25 of 86.
▾Documents — 281 on file (BIS + DOB NOW)
▸Plans & Drawings23
▸DOB NOWPlans/Sketch23
08/22/2026B01134941-S2Request digital key ↗
08/22/2026B01134941-S1Request digital key ↗
08/22/2026B01134941-P1Request digital key ↗
Showing 3 of 23 on file for this type
▸Applications & Permits45
▸BISPLAN / WORK APPROVAL APPLICATION30
03/29/2024301113248Open ↗
11/29/2023301113248Open ↗
11/24/2023320512771Open ↗
Showing 3 of 30 on file for this type
▸BISWORK PERMIT APPLICATION15
08/07/2012320512771Open ↗
08/07/2012320510817Open ↗
08/06/2012320520290Open ↗
Showing 3 of 15 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B01207333-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B01207333-I1Open ↗
▸Seals & Professional Certifications89
▸DOB NOWDPL-1: Design Professional Seal & Signature23
08/22/2026B01134941-S3Open ↗
08/22/2026B01134941-S2Open ↗
08/22/2026B01134941-S1Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWProgress Inspector Seal & Signature22
09/22/2026B01186500-I1Open ↗
09/20/2026B01134941-I1Open ↗
09/20/2026B01134941-I1Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature20
09/23/2026B01219535-S3Open ↗
09/20/2026B01134941-I1Open ↗
09/19/2026B01145391-I1Open ↗
Showing 3 of 20 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION12
12/04/2012320510880Open ↗
11/08/2012320510899Open ↗
08/07/2012320510817Open ↗
Showing 3 of 12 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM7
08/07/2012320510817Open ↗
08/07/2012320512771Open ↗
07/30/2012320520290Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
08/07/2012320510817Open ↗
08/07/2012320512771Open ↗
07/30/2012320520290Open ↗
Showing 3 of 5 on file for this type
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING2
09/28/2012320520290Open ↗
08/30/2012320520290Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
08/31/2012320520290Open ↗
▸Safety & Tenant Protection6
▸BISSTREET TREE CHECKLIST3
04/09/2012320457778Open ↗
04/09/2012320457787Open ↗
04/06/2012320457769Open ↗
▸DOB NOWStreet Tree Checklist2
08/15/2026B01207333-S5Open ↗
08/13/2026B01207333-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B01207333-I1Open ↗
▸Environmental & Asbestos28
▸DOB NOWDEP ACP-5: Asbestos Assessment Report17
08/22/2026B01134941-S2Open ↗
08/22/2026B01134941-S1Open ↗
08/22/2026B01134941-P1Open ↗
Showing 3 of 17 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'5
04/09/2012320457778Open ↗
04/09/2012320457787Open ↗
04/06/2012320457769Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
08/07/2012320512771Open ↗
07/30/2012320520290Open ↗
07/23/2012320510899Open ↗
Showing 3 of 4 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
07/30/2012320520290Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/21/2026B01207333-S3Open ↗
▸Energy Compliance18
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY5
11/30/2023320457778Open ↗
11/30/2023320457787Open ↗
11/29/2023320457778Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: ENERGY3
04/09/2012320457778Open ↗
04/09/2012320457787Open ↗
04/06/2012320457769Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)3
11/28/2023320457787Open ↗
11/28/2023320457778Open ↗
11/28/2023320457769Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
07/31/2012320520290Open ↗
07/23/2012320510880Open ↗
▸BISINTERIOR LIGHTING POWER2
11/28/2023320457787Open ↗
11/28/2023320457778Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS2
11/28/2023320457787Open ↗
11/28/2023320457778Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
12/04/2012320510880Open ↗
▸Inspections & Test Reports17
▸BISTECHNICAL REPORT: RESPONSIBILITY9
11/30/2023320457778Open ↗
11/30/2023320457787Open ↗
11/30/2023320457769Open ↗
Showing 3 of 9 on file for this type
▸BISSTRUCTURAL STABILITY - ALTERATIONS OF EXISTING BUILDINGS3
11/28/2023320457787Open ↗
11/28/2023320457778Open ↗
11/28/2023320512771Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)2
11/28/2023320457787Open ↗
11/28/2023320457778Open ↗
▸BIS* EXIT SIGNS2
11/30/2023320457778Open ↗
11/30/2023320457787Open ↗
▸BIS* FINAL INSPECTION DIRECTIVE 14 OF 19751
11/28/2023301113248Open ↗
▸Approvals, Objections & Sign-offs22
▸BISADMINISTRATIVE OBJECTIONS8
08/06/2012320512771Open ↗
08/06/2012320510817Open ↗
07/30/2012320520290Open ↗
Showing 3 of 8 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST7
12/01/2023320512771Open ↗
12/01/2023320457778Open ↗
12/01/2023320457787Open ↗
Showing 3 of 7 on file for this type
▸BISFINAL6
11/28/2023320457787Open ↗
11/28/2023320457778Open ↗
11/28/2023320457769Open ↗
Showing 3 of 6 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION1
10/26/2012320520290Open ↗
▸Cost, Insurance & Ownership12
▸BISCOST AFFIDAVIT9
12/04/2012320510880Open ↗
11/08/2012320510899Open ↗
09/18/2012320520290Open ↗
Showing 3 of 9 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW33
10/30/2023320457769Open ↗
10/30/2023320457787Open ↗
10/30/2023320457778Open ↗
▸Filing & Intake Forms14
▸BISEFILING COVER SHEET8
08/07/2012320510817Open ↗
08/07/2012320512771Open ↗
07/30/2012320520290Open ↗
Showing 3 of 8 on file for this type
▸BISADDITIONAL INFORMATION4
12/07/2012320520290Open ↗
10/10/2012320520290Open ↗
09/28/2012320520290Open ↗
Showing 3 of 4 on file for this type
▸BISeFiling Job Application Cover Sheet2
07/23/2012320510899Open ↗
07/23/2012320510880Open ↗
▸Other Documents2
▸BIS* VENT. SYS.-ENGINEER/INSTALLER 27-136,7791
11/28/2023301113248Open ↗
▸DOB NOWProperty Ownership Certification1