← Back
Primarily 2 family with 1 store or office
1688 WEBSTER AVENUE
BRONX · Claremont Village-Claremont (East) · BIN 2009409
💬 Discuss this project
1899Year Built
3Stories
S2Building Class
M1-1Zoning
3,750 sfGross Floor Area
3Units
Rent Stabilized1 Open Violation ▸
Primarily 2 family with 1 store or office · 2,250 sf lot · 1.67 FAR built · Flood zone X
Locations of Work
Architecture
Floor 11p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HPD203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
H G LEE ARCHITECT PC210/28/2021
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HG LEE ARCHITECT PC2554110/28/2021
Building Lifecycle
All (39)Filed (2)Violation (23)Objection (12)Special Inspection (2)
11/24/2025
Violation issued (HPD, closed)
I
12/03/2024
Violation issued (HPD, closed)
I
05/15/2024
Violation issued (ECB, closed)
Construction
11/27/2023
Violation issued (HPD, closed)
I
11/16/2022
Violation issued (HPD, closed)
I
03/16/2022
Violation issued (HPD, closed)
I
11/15/2021
Objection raised — Scope
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Fire_Protection
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Scope
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Structural
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Structural
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Fire_Protection
11/15/2021
Objection resolved — Addressed
10/28/2021
Filed — Alteration
NO CHANGE IN USE, EGRESS, AND OCCUPANCY; 1- NEW HAIR WASHING SINK (NON- RESIDENTIAL SINK) ON FIRST FLOOR
X00606807-I1
10/21/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
He Gin Lee
10/07/2021
Filed — Alteration
NO CHANGE IN USE, EGRESS AND OCCUPANCY. 1) DISCONTINUE ILLEGAL HOUSE OF WORSHIP 2) NEW HAIR SALON SAME USE GROUP 6 ON FIRST FLOOR 3) NEW PARTITION WALLS W/ 5/8" GYP. BD. 2 LAYER ON EACH SIDE ON FIRST FLOOR 4) 2 NEW DOORS ON FIRST FLOOR
X00600745-I1
09/27/2021
Special inspection requirement — Fire-Resistance Rated Construction
He Gin Lee
07/01/2021
Violation issued (ECB, closed)
Construction
04/21/2021
Violation issued (HPD, closed)
I
11/08/2019
Violation issued (HPD, closed)
I
01/11/2018
Violation issued (HPD, closed)
I
10/29/2010
Violation issued (HPD, open)
B
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/09/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/17/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/10/1990
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
04/10/1990
Violation issued (ECB, closed)
Boilers
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISPLISSUEDWAGNER ZIV PLMB & HTG CORP02/03/2003
BISOTISSUEDSIDHU CONSTRUCTION CORP.11/29/1996
BISOTISSUEDM.D. CONSTRUCTION CO.03/17/1994
1 project · most recent 10/28/2021
Water/Sanitary
FiledStatusContractorScope
10/28/2021——Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
10/21/2021Fire-Resistant Penetrations and JointsHe Gin Leespecial
09/27/2021Fire-Resistance Rated ConstructionHe Gin Leeprogress
▾Documents — 4 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026X00600745-I1Request digital key ↗
08/15/2026X00606807-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026X00600745-I1Open ↗
08/25/2026X00606807-I1Open ↗