← Back
Two stories - detached, small or mid-size
169-45 23 AVENUE
QUEENS · Bay Terrace-Clearview · BIN 4129344
💬 Discuss this project
1940Year Built
2.5Stories
A1Building Class
R2AZoning
3,115 sfGross Floor Area
1Units
Rent Stabilized3 Open Violations ▸FDNY Report ↗
Two stories - detached, small or mid-size · 5,153 sf lot · 0.6 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Roof2p · 1 filing · 20 docs
Floor 11p · 1 filing · 20 docs
Cellar3p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DHC CONTRACTING103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/08/2021$969K—— → —$311/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PARKER AND WEST ENGINEERING, PLLC104/15/2024
A & T ENGINEERING, P.C.1409/18/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNRUN103/21/2026
A T ENGINEERING P C1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DHC CONTRACTING INCGeneral Contractor807/08/2026
SUNRUN SOLAR ELECTL CORPElectrical203/22/2026
SUNRUN INSTALLATION SVCGeneral Contractor203/21/2026
TRI STATE PLBG & HTG INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PARKER AND WEST ENGINEERI5272104/15/2024
A & T DESIGN GROUP LLC10881309/18/2023
Building Lifecycle
All (104)Filed (15)Permit Issued (7)Signed Off (5)Violation (6)Inspection (7)Objection (34)Special Inspection (30)
11/25/2025
Violation issued (HPD, open)
I
12/04/2024
Violation issued (HPD, open)
I
10/09/2024
Signed off — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01025260-I1
05/10/2024
Permit issued — Solar
Q01025260-I1-SL
04/15/2024
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01025260-I1
03/25/2024
Special inspection requirement — Energy Code Compliance Inspections
Walid Abdulla
03/25/2024
Special inspection requirement — Air barrier - visual inspection
Walid Abdulla
03/25/2024
Special inspection requirement — Final
Walid Abdulla
03/25/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walid Abdulla
03/25/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Walid Abdulla
11/29/2023
Violation issued (HPD, open)
I
11/09/2023
Signed off — Alteration
INTERIOR PLUMBING RENOVATION IN CONJUCTION TO ALTERATION APPLICATION #Q00465551: EXISTING SANITARY AND DOMESTIC WATER DISTRIBUTION. CONVERT TO COMPLY 2014 PLUMBING CODE.
Q00465551-I1
11/08/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
10/06/2023
Special inspection requirement — Concrete - Cast-In-Place
ROBERT LIN
10/06/2023
Special inspection requirement — Heating Systems
ROBERT LIN
10/06/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT LIN
10/06/2023
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
ROBERT LIN
10/06/2023
Special inspection requirement — Structural Steel - High Strength Bolting
ROBERT LIN
10/06/2023
Special inspection requirement — Structural Steel - Welding
ROBERT LIN
10/06/2023
Special inspection requirement — Structural Steel - Details
ROBERT LIN
10/06/2023
Special inspection requirement — Footing and Foundation
ROBERT LIN
10/06/2023
Special inspection requirement — Final
ROBERT LIN
10/06/2023
Special inspection requirement — Fenestration areas
ROBERT LIN
10/06/2023
Special inspection requirement — Interior lighting power
ROBERT LIN
10/06/2023
Special inspection requirement — Permanent certificate
ROBERT LIN
10/06/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
ROBERT LIN
10/06/2023
Special inspection requirement — Insulation placement and R values
ROBERT LIN
10/06/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
ROBERT LIN
10/06/2023
Special inspection requirement — Fenestration air leakage
ROBERT LIN
10/06/2023
Special inspection requirement — HVAC-R and service water heating equipment
ROBERT LIN
10/06/2023
Special inspection requirement — Protection of exposed foundation insulation
ROBERT LIN
10/06/2023
Special inspection requirement — HVAC-R and service water heating system controls
ROBERT LIN
10/06/2023
Special inspection requirement — Mechanical Systems
ROBERT LIN
10/06/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
ROBERT LIN
09/26/2023
Objection resolved — Addressed
09/25/2023
Objection raised — Admin
09/18/2023
Filed — Alteration
INTERIOR PLUMBING RENOVATION IN CONJUCTION TO ALTERATION APPLICATION #Q00465551: EXISTING SANITARY AND DOMESTIC WATER DISTRIBUTION. CONVERT TO COMPLY 2014 PLUMBING CODE.
Q00465551-A5
08/17/2023
Filed — Alteration
INTERIOR PLUMBING RENOVATION IN CONJUCTION TO ALTERATION APPLICATION #Q00465551: EXISTING SANITARY AND DOMESTIC WATER DISTRIBUTION. CONVERT TO COMPLY 2014 PLUMBING CODE.
Q00465551-A3
06/23/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
06/12/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
05/09/2023
Signed off — Alteration
INTERIOR PLUMBING RENOVATION IN CONJUCTION TO ALTERATION APPLICATION #Q00465551: EXISTING SANITARY AND DOMESTIC WATER DISTRIBUTION. CONVERT TO COMPLY 2014 PLUMBING CODE.
Q00465551-S3
05/08/2023
Signed off — Alteration
Q00535106-I1
05/08/2023
Signed off — Alteration
INTERIOR PLUMBING RENOVATION IN CONJUCTION TO ALTERATION APPLICATION #Q00465551: EXISTING SANITARY AND DOMESTIC WATER DISTRIBUTION. CONVERT TO COMPLY 2014 PLUMBING CODE.
Q00465551-S1
04/19/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
ROBERT LIN
04/19/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT LIN
04/19/2023
Special inspection requirement — Energy Code Compliance Inspections
ROBERT LIN
04/14/2023
Filed — Alteration
INTERIOR PLUMBING RENOVATION IN CONJUCTION TO ALTERATION APPLICATION #Q00465551: EXISTING SANITARY AND DOMESTIC WATER DISTRIBUTION. CONVERT TO COMPLY 2014 PLUMBING CODE.
Q00465551-A2
04/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT LIN
03/14/2023
Filed — Alteration
INTERIOR PLUMBING RENOVATION IN CONJUCTION TO ALTERATION APPLICATION #Q00465551: EXISTING SANITARY AND DOMESTIC WATER DISTRIBUTION. CONVERT TO COMPLY 2014 PLUMBING CODE.
Q00465551-A1
02/16/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/31/2023
Permit issued — Plumbing
Q00465551-S3-PL
08/09/2022
Filed — Alteration
INTERIOR PLUMBING RENOVATION IN CONJUCTION TO ALTERATION APPLICATION #Q00465551: EXISTING SANITARY AND DOMESTIC WATER DISTRIBUTION. CONVERT TO COMPLY 2014 PLUMBING CODE.
Q00465551-P9
05/24/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/18/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/06/2022
Violation issued (ECB, closed)
Construction
12/22/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/22/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/01/2021
Filed — Alteration
INTERIOR PLUMBING RENOVATION IN CONJUCTION TO ALTERATION APPLICATION #Q00465551: EXISTING SANITARY AND DOMESTIC WATER DISTRIBUTION. CONVERT TO COMPLY 2014 PLUMBING CODE.
Q00465551-P7
11/19/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/11/2021
Filed — Alteration
INTERIOR PLUMBING RENOVATION IN CONJUCTION TO ALTERATION APPLICATION #Q00465551: EXISTING SANITARY AND DOMESTIC WATER DISTRIBUTION. CONVERT TO COMPLY 2014 PLUMBING CODE.
Q00465551-P6
Latest 60 of 104 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNRUN INSTALLATION SVC05/10/2024
DOB NOWPlumbingSigned-offDW PLUMBING INC01/31/2023
DOB NOWPlumbingSigned-offDW PLUMBING INC11/10/2021
DOB NOWFoundationSigned-offALEXANDER CHAN11/04/2021
DOB NOWGeneral ConstructionSigned-offALEXANDER CHAN07/15/2021
DOB NOWSupport of ExcavationSigned-offALEXANDER CHAN07/01/2021
DOB NOWConstruction FenceSigned-offALEXANDER CHAN06/29/2021
BISOTISSUEDSUNRUN INSTALLATION SVC10/12/2022
BISOTISSUEDSAL SALAMONE GEN CONTR09/18/2018
BISOTISSUEDN/A04/02/1998
3 projects · most recent 04/15/2024
General Wiring
FiledStatusContractorScope
04/15/2024CompleteSUNRUN SOLAR ELECTL CORP—
05/16/2023CompleteJEM ELEC'L CONTR. CORPGeneral Wiring
10/12/2022CompleteSUNRUN SOLAR ELECTL CORP—
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
11/08/2023Pass-Final General Construction Non-Directive 14PassView ↗
06/23/2023Fail-Final General Construction Non-Directive 14FailView ↗
06/12/2023Fail-Final General Construction Non-Directive 14FailView ↗
02/16/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/22/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/22/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/19/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 59
DateRequirementInspectorRole
03/25/2024Energy Code Compliance InspectionsWalid Abdullaprogress
03/25/2024Air barrier - visual inspectionWalid Abdullaenergy_progress
03/25/2024FinalWalid Abdullaprogress
03/25/2024Fire-Resistant Penetrations and JointsWalid Abdullaspecial
03/25/2024Structural Stability – Alterations of existing buildingsWalid Abdullaspecial
10/06/2023Concrete - Cast-In-PlaceROBERT LINspecial
10/06/2023Heating SystemsROBERT LINspecial
10/06/2023Fire-Resistant Penetrations and JointsROBERT LINspecial
10/06/2023Excavations - Sheeting, Shoring, and BracingROBERT LINspecial
10/06/2023Structural Steel - High Strength BoltingROBERT LINspecial
10/06/2023Structural Steel - WeldingROBERT LINspecial
10/06/2023Structural Steel - DetailsROBERT LINspecial
10/06/2023Footing and FoundationROBERT LINprogress
10/06/2023FinalROBERT LINprogress
10/06/2023Fenestration areasROBERT LINenergy_progress
10/06/2023Interior lighting powerROBERT LINenergy_progress
10/06/2023Permanent certificateROBERT LINenergy_progress
10/06/2023HVAC-R and service water piping design and insulationROBERT LINenergy_progress
10/06/2023Insulation placement and R valuesROBERT LINenergy_progress
10/06/2023Fenestration and door U-factor and product ratingsROBERT LINenergy_progress
10/06/2023Fenestration air leakageROBERT LINenergy_progress
10/06/2023HVAC-R and service water heating equipmentROBERT LINenergy_progress
10/06/2023Protection of exposed foundation insulationROBERT LINenergy_progress
10/06/2023HVAC-R and service water heating system controlsROBERT LINenergy_progress
10/06/2023Mechanical SystemsROBERT LINspecial
Latest 25 of 59.
▾Documents — 176 on file (BIS + DOB NOW)
▸Plans & Drawings39
▸DOB NOWPlans/Sketch9
08/27/2026Q00535106-I1Request digital key ↗
08/27/2026Q00465551-A2Request digital key ↗
08/27/2026Q00465551-A1Request digital key ↗
Showing 3 of 9 on file for this type
▸DOB NOWPlans/Sketch - Earthwork6
08/27/2026Q00465551-P1Request digital key ↗
08/27/2026Q00465551-A5Request digital key ↗
08/27/2026Q00465551-A3Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems6
08/27/2026Q00465551-P1Request digital key ↗
08/27/2026Q00465551-P2Request digital key ↗
08/27/2026Q00465551-A5Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - General Construction6
08/27/2026Q00465551-P2Request digital key ↗
08/27/2026Q00465551-P1Request digital key ↗
08/27/2026Q00465551-A5Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Foundation6
08/27/2026Q00465551-P1Request digital key ↗
08/27/2026Q00465551-A5Request digital key ↗
08/27/2026Q00465551-A3Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Structural6
08/27/2026Q00465551-P1Request digital key ↗
08/27/2026Q00465551-P2Request digital key ↗
08/27/2026Q00465551-A5Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits4
▸BISWORK PERMIT APPLICATION2
10/12/2022440749843Open ↗
10/15/2018421650243Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
10/07/2022440749843Open ↗
09/26/2018421650243Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram6
08/13/2026Q00465551-P6Open ↗
08/13/2026Q00465551-P1Open ↗
08/13/2026Q00465551-A3Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications58
▸DOB NOWSpecial Inspector Seal & Signature19
09/01/2026Q00465551-P7Open ↗
08/28/2026Q00465551-S3Open ↗
08/28/2026Q00465551-P2Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWProgress Inspector Seal & Signature16
09/01/2026Q00465551-P7Open ↗
09/01/2026Q00465551-P7Open ↗
08/28/2026Q00465551-S3Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature15
08/27/2026Q00535106-I1Open ↗
08/27/2026Q00465551-I1Open ↗
08/27/2026Q00465551-P1Open ↗
Showing 3 of 15 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
08/13/2019421650243Open ↗
10/15/2018421650243Open ↗
09/26/2018421650243Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
10/07/2022440749843Open ↗
09/26/2018421650243Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/26/2018421650243Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/07/2022440749843Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
10/07/2022440749843Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
09/26/2018421650243Open ↗
▸BISTPP1: TENANT PROTECTION PLAN1
10/12/2022440749843Open ↗
▸Environmental & Asbestos14
▸DOB NOWDEP ACP-5: Asbestos Assessment Report12
08/27/2026Q00465551-A5Open ↗
08/27/2026Q00465551-A3Open ↗
08/27/2026Q00465551-A2Open ↗
Showing 3 of 12 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
10/07/2022440749843Open ↗
09/26/2018421650243Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
03/01/2023440749843Open ↗
10/07/2022440749843Open ↗
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026Q00465551-I1Open ↗
08/13/2026Q00465551-S3Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
03/07/2023440749843Open ↗
▸BISNYCECC ANALYSIS1
10/07/2022440749843Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
10/07/2022440749843Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/07/2022440749843Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
03/01/2023440749843Open ↗
▸Inspections & Test Reports6
▸BISTECHNICAL REPORT: RESPONSIBILITY2
03/01/2023440749843Open ↗
10/07/2022440749843Open ↗
▸BISINSPECTION REPORT - SUPPORTING DOCUMENTATION1
08/14/2019421650243Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q00465551-S1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00465551-S1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00465551-S1Open ↗
▸Approvals, Objections & Sign-offs8
▸BISLETTERS - SUPPORTING DOCUMENTATION4
03/07/2023440749843Open ↗
03/07/2023440749843Open ↗
10/07/2022440749843Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
03/07/2023440749843Open ↗
08/14/2019421650243Open ↗
08/12/2019421650243Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01025260-I1Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
03/01/2023440749843Open ↗
10/07/2022440749843Open ↗
08/13/2019421650243Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET1
09/26/2018421650243Open ↗
▸BISADDITIONAL INFORMATION1
09/18/2018421650243Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/07/2022440749843Open ↗
▸BISBOROUGH INTAKE FORM1
08/12/2019421650243Open ↗
▸Other Documents22
▸DOB NOWPlot Diagram7
08/13/2026Q00465551-A3Open ↗
08/13/2026Q00465551-P1Open ↗
08/13/2026Q00465551-P2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSite Survey: Initial6
08/13/2026Q00465551-P1Open ↗
08/13/2026Q00465551-P6Open ↗
08/13/2026Q00465551-A3Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone6
08/13/2026Q00465551-P6Open ↗
08/13/2026Q00465551-A5Open ↗
08/13/2026Q00465551-A3Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWAdjoining Owners Notification2
08/13/2026Q00465551-I1Open ↗
08/13/2026Q00465551-S1Open ↗
▸DOB NOWSURVEY: INITIAL1
08/13/2026Q00465551-S1Open ↗