← Back
One family attached or semi-detached
17-04 WILLOUGHBY AVENUE
QUEENS · Ridgewood · BIN 4081630
💬 Discuss this project
1945Year Built
2Stories
A5Building Class
R4Zoning
1,332 sfGross Floor Area
1Units
One family attached or semi-detached · 1,802 sf lot · 0.74 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 219p · 3 filings · 20 docs
Floor 118p · 3 filings · 20 docs
Cellar34p · 3 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/10/2021$975K—— → —$732/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STEPHEN ANDENMATTEN1107/21/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CODE2203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PK & SONS HOME IMPROVEMENGeneral Contractor407/08/2026
EH PLUMBING & HEATING CORPlumbing207/08/2026
BRANDL ELECTRIC INC.Electrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WELLS DESIGN & CONSULTING7750304/14/2022
Building Lifecycle
All (40)Filed (11)Permit Issued (4)Signed Off (2)Inspection (5)Special Inspection (18)
08/02/2022
Permit issued — Plumbing
Q00502823-I1-PL
07/21/2022
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH AN INTERIOR RENOVATION OF AN EXISTING TOWNHOUSE. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
Q00502823-P3
07/20/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
06/21/2022
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH AN INTERIOR RENOVATION OF AN EXISTING TOWNHOUSE. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
Q00502823-P2
06/13/2022
Signed off — Alteration
MECHANICAL WORK IN CONJUNCTION WITH AN INTERIOR RENOVATION OF AN EXISTING TOWNHOUSE. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
Q00502838-I1
06/13/2022
Signed off — Alteration
Q00495524-I1
06/07/2022
Special inspection requirement — Mechanical Systems
Tyrone Wells
06/07/2022
Special inspection requirement — HVAC-R and service water heating system controls
STEPHEN ANDENMATTEN
06/07/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
STEPHEN ANDENMATTEN
06/07/2022
Special inspection requirement — HVAC-R and service water heating equipment
STEPHEN ANDENMATTEN
06/07/2022
Special inspection requirement — Final
STEPHEN ANDENMATTEN
04/14/2022
Filed — Alteration
MECHANICAL WORK IN CONJUNCTION WITH AN INTERIOR RENOVATION OF AN EXISTING TOWNHOUSE. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
Q00502838-P4
04/14/2022
Special inspection requirement — HVAC-R and service water heating equipment
STEPHEN ANDENMATTEN
04/14/2022
Special inspection requirement — Mechanical Systems
Tyrone Wells
04/14/2022
Special inspection requirement — Final
STEPHEN ANDENMATTEN
04/14/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
STEPHEN ANDENMATTEN
04/14/2022
Special inspection requirement — HVAC-R and service water heating system controls
STEPHEN ANDENMATTEN
03/10/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/24/2022
Special inspection requirement — Final
STEPHEN ANDENMATTEN
02/19/2022
Filed — Alteration
Q00495524-P2
02/18/2022
Special inspection requirement — Final
STEPHEN ANDENMATTEN
07/07/2021
Filed — Alteration
MECHANICAL WORK IN CONJUNCTION WITH AN INTERIOR RENOVATION OF AN EXISTING TOWNHOUSE. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
Q00502838-P3
06/30/2021
Permit issued — Mechanical Systems
Q00502838-I1-MS
06/28/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/28/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/28/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/14/2021
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH AN INTERIOR RENOVATION OF AN EXISTING TOWNHOUSE. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
Q00502823-P1
06/01/2021
Permit issued — Plumbing
Q00502823-I1-PL
05/13/2021
Permit issued — General Construction
Q00495524-I1-GC
05/07/2021
Filed — Alteration
Q00495524-P1
05/07/2021
Filed — Alteration
MECHANICAL WORK IN CONJUNCTION WITH AN INTERIOR RENOVATION OF AN EXISTING TOWNHOUSE. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
Q00502838-P2
05/07/2021
Special inspection requirement — Final
STEPHEN ANDENMATTEN
05/07/2021
Special inspection requirement — HVAC-R and service water heating system controls
STEPHEN ANDENMATTEN
05/07/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
STEPHEN ANDENMATTEN
05/07/2021
Special inspection requirement — HVAC-R and service water heating equipment
STEPHEN ANDENMATTEN
05/07/2021
Special inspection requirement — Final
STEPHEN ANDENMATTEN
05/07/2021
Special inspection requirement — Mechanical Systems
04/21/2021
Filed — Alteration
MECHANICAL WORK IN CONJUNCTION WITH AN INTERIOR RENOVATION OF AN EXISTING TOWNHOUSE. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
Q00502838-I1
04/21/2021
Filed — Alteration
Q00495524-I1
04/21/2021
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH AN INTERIOR RENOVATION OF AN EXISTING TOWNHOUSE. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
Q00502823-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offEH PLUMBING & HEATING COR08/02/2022
DOB NOWMechanical SystemsSigned-offPK & SONS HOME IMPROVEMEN06/30/2021
DOB NOWPlumbingSigned-offEH PLUMBING & HEATING COR06/01/2021
DOB NOWGeneral ConstructionSigned-offPK & SONS HOME IMPROVEMEN05/13/2021
1 project · most recent 07/21/2022
Gas Water/Sanitary
FiledStatusContractorScope
07/21/2022Signed-offEH PLUMBING & HEATING CORGas, Water/Sanitary
1 project · most recent 05/20/2021
General Wiring
FiledStatusContractorScope
05/20/2021CompleteBRANDL ELECTRIC INC.General Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/20/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/10/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
06/28/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/28/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/28/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
06/07/2022Mechanical SystemsTyrone Wellsspecial
06/07/2022HVAC-R and service water heating system controlsSTEPHEN ANDENMATTENenergy_progress
06/07/2022HVAC-R and service water piping design and insulationSTEPHEN ANDENMATTENenergy_progress
06/07/2022HVAC-R and service water heating equipmentSTEPHEN ANDENMATTENenergy_progress
06/07/2022FinalSTEPHEN ANDENMATTENprogress
04/14/2022HVAC-R and service water heating equipmentSTEPHEN ANDENMATTENenergy_progress
04/14/2022Mechanical SystemsTyrone Wellsspecial
04/14/2022FinalSTEPHEN ANDENMATTENprogress
04/14/2022HVAC-R and service water piping design and insulationSTEPHEN ANDENMATTENenergy_progress
04/14/2022HVAC-R and service water heating system controlsSTEPHEN ANDENMATTENenergy_progress
02/24/2022FinalSTEPHEN ANDENMATTENprogress
02/18/2022FinalSTEPHEN ANDENMATTENprogress
05/07/2021FinalSTEPHEN ANDENMATTENprogress
05/07/2021HVAC-R and service water heating system controlsSTEPHEN ANDENMATTENenergy_progress
05/07/2021HVAC-R and service water piping design and insulationSTEPHEN ANDENMATTENenergy_progress
05/07/2021HVAC-R and service water heating equipmentSTEPHEN ANDENMATTENenergy_progress
05/07/2021FinalSTEPHEN ANDENMATTENprogress
05/07/2021Mechanical Systems—special
▾Documents — 46 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/27/2026Q00495524-I1Request digital key ↗
08/27/2026Q00495524-P1Request digital key ↗
08/27/2026Q00495524-P2Request digital key ↗
Showing 3 of 11 on file for this type
▸Seals & Professional Certifications23
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/26/2026Q00502838-I1Open ↗
08/26/2026Q00502838-P4Open ↗
08/26/2026Q00502838-P3Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWProgress Inspector Seal & Signature10
09/25/2026Q00502838-P4Open ↗
09/25/2026Q00502838-P4Open ↗
09/25/2026Q00502838-P4Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/25/2026Q00502838-P4Open ↗
09/01/2026Q00502838-I1Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report11
08/26/2026Q00502838-P4Open ↗
08/26/2026Q00502838-P2Open ↗
08/26/2026Q00502838-I1Open ↗
Showing 3 of 11 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00502838-I1Open ↗