← Back
Two family frame
17-05 FRANCIS LEWIS BLVD
QUEENS · BIN 4623684
💬 Discuss this project
2022Year Built
2Stories
B2Building Class
R3-2Zoning
1,664 sfGross Floor Area
2Units
Two family frame · 2,855 sf lot · 0.58 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbingFire Protection
Floor 213p · 2 filings · 20 docs
Floor 113p · 2 filings · 20 docs
Cellar17p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
STACK CONSTRUCTION2307/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/09/2025$1.3M—— → —$808/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FABIAN CRUZ PE PLLC706/15/2023
GERALD CALIENDO ARCHITECTS406/02/2023
RAS PE CONSULTING ENGINEERS301/14/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
COMMERCIAL CAPITAL USA203/21/2026
GERALD J CALIENDO R A A I A AR603/21/2026
GERALD J. CALIENDO R.A., P.C.103/21/2026
GERALD J CALIENDO R A P C103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
STACK CONSTRUCTION LLCGeneral Contractor1007/08/2026
FOUR POINTS P & H CORPPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BRIAN E. FLYNN, PE, PC28371106/02/2023
Building Lifecycle
All (77)Filed (14)Permit Issued (8)Signed Off (5)Inspection (10)Objection (10)Special Inspection (30)
02/19/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/14/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/07/2023
Signed off — Alteration
Plumbing work filed in conjunction with NB Q00503008-I1 and to supersede all plumbing work that was concluded under Q00503008-S3.
Q00889892-I1
08/28/2023
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
08/24/2023
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
08/24/2023
Inspection — Certified Sprinkler (PL) - SP - Roughing
Certified
View inspection ↗
08/10/2023
Permit issued — Plumbing
Q00889892-I1-PL
08/01/2023
Objection resolved — Addressed
07/03/2023
Objection resolved — Addressed
07/03/2023
Objection resolved — Addressed
07/03/2023
Objection resolved — Addressed
07/03/2023
Objection resolved — Addressed
06/30/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/25/2023
Objection raised — Admin
06/25/2023
Objection raised — Structural
06/25/2023
Objection raised — Structural
06/25/2023
Objection raised — Zoning
06/25/2023
Objection raised — Structural
06/15/2023
Filed — Alteration
Plumbing work filed in conjunction with NB Q00503008-I1 and to supersede all plumbing work that was concluded under Q00503008-S3.
Q00889892-I1
06/12/2023
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
06/09/2023
Signed off — New Building
HEREWITH FILED NB APPLICATION FOR A (2) TWO STORY (2) TWO FAMILY RESIDENTIAL BUILDING WITH CELLAR AND TO OBTAIN NEW C.O., AND TO SUBDIVIDE EXISTING LOT 26 INTO TWO TAX LOTS WITH TWO (2) SEPARATE ZONING LOTS.
Q00503008-S2
06/07/2023
Special inspection requirement — Air barrier — testing
BRIAN FLYNN
06/07/2023
Special inspection requirement — Air barrier - visual inspection
BRIAN FLYNN
06/07/2023
Special inspection requirement — Fenestration areas
BRIAN FLYNN
06/07/2023
Special inspection requirement — Fenestration air leakage
BRIAN FLYNN
06/07/2023
Special inspection requirement — Fire-Resistance Rated Construction
BRIAN FLYNN
06/07/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
BRIAN FLYNN
06/07/2023
Special inspection requirement — Insulation placement and R values
BRIAN FLYNN
06/07/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN FLYNN
06/07/2023
Special inspection requirement — Energy Code Compliance Inspections
BRIAN FLYNN
06/02/2023
Filed — New Building
HEREWITH FILED NB APPLICATION FOR A (2) TWO STORY (2) TWO FAMILY RESIDENTIAL BUILDING WITH CELLAR AND TO OBTAIN NEW C.O., AND TO SUBDIVIDE EXISTING LOT 26 INTO TWO TAX LOTS WITH TWO (2) SEPARATE ZONING LOTS.
Q00503008-P6
05/29/2023
Special inspection requirement — Lighting in dwelling units
BRIAN FLYNN
05/29/2023
Special inspection requirement — Final
BRIAN FLYNN
05/29/2023
Special inspection requirement — HVAC-R and service water heating system controls
BRIAN FLYNN
05/29/2023
Special inspection requirement — Energy Code Compliance Inspections
BRIAN FLYNN
05/29/2023
Special inspection requirement — Mechanical Systems
BRIAN FLYNN
05/29/2023
Special inspection requirement — Maintenance information
BRIAN FLYNN
05/29/2023
Special inspection requirement — Interior lighting power
BRIAN FLYNN
05/29/2023
Special inspection requirement — Heating Systems
BRIAN FLYNN
05/29/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
BRIAN FLYNN
05/29/2023
Special inspection requirement — Lighting controls
BRIAN FLYNN
05/29/2023
Special inspection requirement — HVAC-R and service water heating equipment
BRIAN FLYNN
05/29/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN FLYNN
05/29/2023
Special inspection requirement — Exterior lighting power
BRIAN FLYNN
05/25/2023
Filed — New Building
HEREWITH FILED NB APPLICATION FOR A (2) TWO STORY (2) TWO FAMILY RESIDENTIAL BUILDING WITH CELLAR AND TO OBTAIN NEW C.O., AND TO SUBDIVIDE EXISTING LOT 26 INTO TWO TAX LOTS WITH TWO (2) SEPARATE ZONING LOTS.
Q00503008-P7
05/24/2023
Signed off — New Building
HEREWITH FILED NB APPLICATION FOR A (2) TWO STORY (2) TWO FAMILY RESIDENTIAL BUILDING WITH CELLAR AND TO OBTAIN NEW C.O., AND TO SUBDIVIDE EXISTING LOT 26 INTO TWO TAX LOTS WITH TWO (2) SEPARATE ZONING LOTS.
Q00503008-S4
05/24/2023
Permit issued — Structural
Q00503008-S4-ST
05/19/2023
Signed off — New Building
HEREWITH FILED NB APPLICATION FOR A (2) TWO STORY (2) TWO FAMILY RESIDENTIAL BUILDING WITH CELLAR AND TO OBTAIN NEW C.O., AND TO SUBDIVIDE EXISTING LOT 26 INTO TWO TAX LOTS WITH TWO (2) SEPARATE ZONING LOTS.
Q00503008-S1
05/09/2023
Permit issued — Mechanical Systems
Q00503008-S2-MS
05/09/2023
Special inspection requirement — Fenestration air leakage
BRIAN FLYNN
05/09/2023
Special inspection requirement — Air barrier - visual inspection
BRIAN FLYNN
05/09/2023
Special inspection requirement — Air barrier — testing
BRIAN FLYNN
05/09/2023
Special inspection requirement — Fire-Resistance Rated Construction
BRIAN FLYNN
05/09/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN FLYNN
05/09/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
BRIAN FLYNN
05/09/2023
Special inspection requirement — Insulation placement and R values
BRIAN FLYNN
05/09/2023
Special inspection requirement — Fenestration areas
BRIAN FLYNN
05/08/2023
Signed off — Alteration
Herewith filed for the installation of a 8 ft plywood construction fence for 17-05 & 17-07 Francis Lewis Blvd, Lots 26 & 30. In conjunction with DOB Now job numbers Q00503008 and Q00503014
Q00680824-I1
05/02/2023
Filed — New Building
HEREWITH FILED NB APPLICATION FOR A (2) TWO STORY (2) TWO FAMILY RESIDENTIAL BUILDING WITH CELLAR AND TO OBTAIN NEW C.O., AND TO SUBDIVIDE EXISTING LOT 26 INTO TWO TAX LOTS WITH TWO (2) SEPARATE ZONING LOTS.
Q00503008-P5
01/05/2023
Permit issued — General Construction
Q00503008-I1-GC
Latest 60 of 77 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offFOUR POINTS P & H CORP08/10/2023
DOB NOWStructuralSigned-offSTACK CONSTRUCTION LLC05/24/2023
DOB NOWMechanical SystemsSigned-offSTACK CONSTRUCTION LLC05/09/2023
DOB NOWGeneral ConstructionPermit IssuedSTACK CONSTRUCTION LLC01/05/2023
DOB NOWPlumbingSigned-offFOUR POINTS P & H CORP06/23/2022
DOB NOWGeneral ConstructionPermit IssuedSTACK CONSTRUCTION LLC03/08/2022
DOB NOWFoundationSigned-offSTACK CONSTRUCTION LLC03/04/2022
DOB NOWConstruction FenceSigned-offSTACK CONSTRUCTION LLC02/22/2022
1 project · most recent 06/02/2023
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
06/02/2023Signed-offSTACK CONSTRUCTION LLCAir Conditioning Systems, Heating Systems
Cooling
Mitsubishi Electric MXZ-8C48NAHZ2 48,000 BTU · Heat Pump Outdoor ×2
Heating
Mitsubishi Electric MXZ-8C48NAHZ2 54,000 BTU · Heat Pump Outdoor ×2
1 project · most recent 06/02/2023
Gas Storm Water/Sanitary
FiledStatusContractorScope
06/02/2023Signed-offFOUR POINTS P & H CORPGas, Storm, Water/Sanitary
1 project · most recent 07/26/2023
General Wiring
FiledStatusContractorScope
07/26/2023CompleteMARTINEZ ELECTRICAL CONTGeneral Wiring
1 project · most recent 06/02/2023
Steel Wood
FiledStatusContractorScope
06/02/2023Signed-offSTACK CONSTRUCTION LLCSteel, Wood
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
02/19/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/14/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/28/2023Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
08/24/2023Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
08/24/2023Certified Sprinkler (PL) - SP - RoughingCertifiedView ↗
06/30/2023Pass-Final CND-Occupancy InspectionPassView ↗
06/12/2023Fail-Final CND-Occupancy InspectionFailView ↗
09/23/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/10/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
08/10/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 83
DateRequirementInspectorRole
06/07/2023Fire-Resistant Penetrations and JointsBRIAN FLYNNspecial
06/07/2023Energy Code Compliance InspectionsBRIAN FLYNNprogress
06/07/2023Fire-Resistance Rated ConstructionBRIAN FLYNNprogress
06/07/2023Fenestration air leakageBRIAN FLYNNenergy_progress
06/07/2023Fenestration areasBRIAN FLYNNenergy_progress
06/07/2023Fenestration and door U-factor and product ratingsBRIAN FLYNNenergy_progress
06/07/2023Insulation placement and R valuesBRIAN FLYNNenergy_progress
06/07/2023Air barrier — testing BRIAN FLYNNenergy_progress
06/07/2023Air barrier - visual inspectionBRIAN FLYNNenergy_progress
05/29/2023Mechanical SystemsBRIAN FLYNNspecial
05/29/2023Lighting in dwelling unitsBRIAN FLYNNenergy_progress
05/29/2023HVAC-R and service water heating equipmentBRIAN FLYNNenergy_progress
05/29/2023Interior lighting powerBRIAN FLYNNenergy_progress
05/29/2023Maintenance informationBRIAN FLYNNenergy_progress
05/29/2023Exterior lighting powerBRIAN FLYNNenergy_progress
05/29/2023FinalBRIAN FLYNNprogress
05/29/2023Energy Code Compliance InspectionsBRIAN FLYNNprogress
05/29/2023Fire-Resistant Penetrations and JointsBRIAN FLYNNspecial
05/29/2023Heating SystemsBRIAN FLYNNspecial
05/29/2023Lighting controlsBRIAN FLYNNenergy_progress
05/29/2023HVAC-R and service water piping design and insulationBRIAN FLYNNenergy_progress
05/29/2023HVAC-R and service water heating system controlsBRIAN FLYNNenergy_progress
05/09/2023Energy Code Compliance InspectionsBRIAN FLYNNprogress
05/09/2023Fire-Resistance Rated ConstructionBRIAN FLYNNprogress
05/09/2023Air barrier — testing BRIAN FLYNNenergy_progress
Latest 25 of 83.
▾Documents — 117 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch14
08/27/2026Q00503008-P1Request digital key ↗
08/27/2026Q00503008-S4Request digital key ↗
08/27/2026Q00503008-P2Request digital key ↗
Showing 3 of 14 on file for this type
▸Zoning, Tax Lot & Property Records7
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026Q00503008-P6Open ↗
08/13/2026Q00503008-P3Open ↗
08/13/2026Q00503008-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)3
08/13/2026Q00503008-P6Open ↗
08/13/2026Q00503008-P3Open ↗
08/13/2026Q00503008-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00503008-I1Open ↗
▸Seals & Professional Certifications70
▸DOB NOWProgress Inspector Seal & Signature38
08/27/2026Q00503008-S1Open ↗
08/27/2026Q00503008-S1Open ↗
08/24/2026Q00503008-S2Open ↗
Showing 3 of 38 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature18
09/01/2026Q00503008-P5Open ↗
09/01/2026Q00503008-P5Open ↗
08/27/2026Q00503008-S1Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature14
08/27/2026Q00503008-S3Open ↗
08/27/2026Q00503008-P1Open ↗
08/27/2026Q00503008-S4Open ↗
Showing 3 of 14 on file for this type
▸Trade Schedules & Equipment4
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/13/2026Q00503008-I1Open ↗
08/13/2026Q00503008-P6Open ↗
08/13/2026Q00503008-P3Open ↗
▸DOB NOWStandpipe Alarms Drawings1
08/13/2026Q00503008-I1—
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist3
08/13/2026Q00503008-P3Open ↗
08/13/2026Q00503008-P6Open ↗
08/13/2026Q00503008-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026Q00503008-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q00503008-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00503008-I1Open ↗
▸Energy Compliance3
▸DOB NOWEN2: As Built Energy Analysis.3
08/13/2026Q00503008-S2Open ↗
08/13/2026Q00503008-S3Open ↗
08/13/2026Q00503008-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/13/2026Q00503008-S1Open ↗
08/13/2026Q00503008-P1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00503008-S1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00503008-S1Open ↗
▸Other Documents9
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026Q00503008-I1Open ↗
08/13/2026Q00503008-P6Open ↗
08/13/2026Q00503008-P3Open ↗
▸DOB NOWProperty Ownership Certification2
08/27/2026Q00503008-P2Open ↗
08/27/2026Q00503008-P4Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026Q00503008-P6Open ↗
08/13/2026Q00503008-I1Open ↗
▸DOB NOWTR5H Test Report1
08/13/2026Q00503008-S1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00503008-I1Open ↗