| Owner | Filings | Most Recent |
|---|---|---|
| STACK CONSTRUCTION | 22 | 07/08/2026 |
| 17-11 FRANCIS LEWIS REALTY | 3 | 03/21/2026 |
| 17-11 FRANCIS LEWIS BLVD | 2 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 09/27/2024 | $1.4M | — | — → — | $696/sf building |
| 03/23/2018 | $825K | — | Private party → 17-11 FRANCIS LEWIS REALTY LLC | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| GERALD CALIENDO ARCHITECTS | 9 | 08/22/2024 |
| FABIAN CRUZ PE PLLC | 4 | 05/25/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| GERALD J CALIENDO R A A I A AR | 12 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| STACK CONSTRUCTION LLC | General Contractor | 14 | 07/08/2026 |
| CN PLUMBING INC | Fire Protection | 1 | 07/08/2026 |
| FOUR POINTS P & H CORP | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| BRIAN E. FLYNN, PE, PC | 2837 | 11 | 08/22/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Structural | Signed-off | STACK CONSTRUCTION LLC | 05/24/2023 |
| DOB NOW | Curb Cut | Signed-off | STACK CONSTRUCTION LLC | 05/24/2023 |
| DOB NOW | Mechanical Systems | Signed-off | STACK CONSTRUCTION LLC | 05/09/2023 |
| DOB NOW | Plumbing | Signed-off | CN PLUMBING INC | 04/10/2023 |
| DOB NOW | General Construction | Permit Issued | STACK CONSTRUCTION LLC | 01/04/2023 |
| DOB NOW | Plumbing | Signed-off | FOUR POINTS P & H CORP | 06/23/2022 |
| DOB NOW | General Construction | Permit Issued | STACK CONSTRUCTION LLC | 03/12/2022 |
| DOB NOW | Foundation | Signed-off | STACK CONSTRUCTION LLC | 03/04/2022 |
| BIS | OT | ISSUED | AMBER ELECTRICAL CONTRACT | 03/21/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/22/2024 | Signed-off | STACK CONSTRUCTION LLC | Heating and Air Conditioning Systems | Heat / Cool Cooper & Hunter SOPHIA MULTI-ZONE INVERTER CH-48MSPH230VO 48,000 BTU · Heat Pump Outdoor ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/22/2024 | Signed-off | CN PLUMBING INC | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/22/2024 | Signed-off | FOUR POINTS P & H CORP | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/12/2023 | Complete | MARTINEZ ELECTRICAL CONT | General Wiring |
| 03/12/2023 | Complete | AMBER ELECTL CONTNG INC | — |
| 03/12/2023 | Cancelled | AMBER ELECTL CONTNG INC | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/22/2024 | Signed-off | STACK CONSTRUCTION LLC | Steel, Masonry, Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 05/20/2025 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 07/26/2023 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 06/30/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 06/21/2023 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 06/14/2023 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 06/12/2023 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 05/30/2023 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 05/24/2023 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 05/19/2023 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 09/23/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 08/10/2022 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 08/10/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/22/2024 | Air barrier - visual inspection | BRIAN FLYNN | energy_progress |
| 08/22/2024 | Fenestration air leakage | BRIAN FLYNN | energy_progress |
| 08/22/2024 | Insulation placement and R values | BRIAN FLYNN | energy_progress |
| 08/22/2024 | Air barrier — testing | BRIAN FLYNN | energy_progress |
| 08/22/2024 | Fenestration and door U-factor and product ratings | BRIAN FLYNN | energy_progress |
| 08/22/2024 | Fenestration areas | BRIAN FLYNN | energy_progress |
| 08/22/2024 | Fire-Resistant Penetrations and Joints | BRIAN FLYNN | special |
| 08/22/2024 | Fire-Resistance Rated Construction | BRIAN FLYNN | progress |
| 08/22/2024 | Energy Code Compliance Inspections | BRIAN FLYNN | progress |
| 08/21/2024 | Air barrier — testing | BRIAN FLYNN | energy_progress |
| 08/21/2024 | Fire-Resistant Penetrations and Joints | BRIAN FLYNN | special |
| 08/21/2024 | Energy Code Compliance Inspections | BRIAN FLYNN | progress |
| 08/21/2024 | Fire-Resistance Rated Construction | BRIAN FLYNN | progress |
| 08/21/2024 | Insulation placement and R values | BRIAN FLYNN | energy_progress |
| 08/21/2024 | Air barrier - visual inspection | BRIAN FLYNN | energy_progress |
| 08/21/2024 | Fenestration areas | BRIAN FLYNN | energy_progress |
| 08/21/2024 | Fenestration air leakage | BRIAN FLYNN | energy_progress |
| 08/21/2024 | Fenestration and door U-factor and product ratings | BRIAN FLYNN | energy_progress |
| 05/22/2023 | Final | BRIAN FLYNN | progress |
| 05/22/2023 | Lighting in dwelling units | BRIAN FLYNN | energy_progress |
| 05/22/2023 | Interior lighting power | BRIAN FLYNN | energy_progress |
| 05/22/2023 | Exterior lighting power | BRIAN FLYNN | energy_progress |
| 05/22/2023 | HVAC-R and service water heating system controls | BRIAN FLYNN | energy_progress |
| 05/22/2023 | Maintenance information | BRIAN FLYNN | energy_progress |
| 05/22/2023 | HVAC-R and service water piping design and insulation | BRIAN FLYNN | energy_progress |