← Back
Professional building / stand-alone funeral home
17-52 FRANCIS LEWIS BLVD
QUEENS · Whitestone-Beechhurst · BIN 4107654
💬 Discuss this project
1952Year Built
1Stories
O7Building Class
R2AZoning
4,200 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Professional building / stand-alone funeral home · Owner of record: WHITESTONE PROPERTIES MANAGEMENT LLC · 5,095 sf lot · 0.82 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Cellar1p · 1 filing · 6 docs
Site & exterior1 filing · 6 docs
Filed — no permit issued1p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WHITESTONE PROPERTIES MAN103/22/2026
MFS GROUP LLC 35 FOXHUNT103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/15/2023$1.5M—— → —$357/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SBLM ARCHITECTS, PC110/23/2023
BAZINI ENGINEERING, P.C.103/18/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DAVID B NICHOLSON RA103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NULITE FUEL OIL CO., LTDGeneral Contractor607/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BAZINI ENGINEERING, P.C.1808103/18/2020
Building Lifecycle
All (13)Filed (2)Permit Issued (4)Signed Off (1)Violation (3)Special Inspection (3)
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/23/2023
Filed — Alteration
Q00951529-I1
09/27/2023
Violation issued (ECB, open)
Construction
06/07/2022
Signed off — Alteration
REPLACE AIR HANDLER AND CONDENSER UNIT AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00318152-I1
03/18/2022
Permit issued — Mechanical Systems
Q00318152-I1-MS
03/24/2021
Permit issued — Mechanical Systems
Q00318152-I1-MS
09/22/2020
Permit issued — Mechanical Systems
Q00318152-I1-MS
03/20/2020
Permit issued — Mechanical Systems
Q00318152-I1-MS
03/18/2020
Filed — Alteration
REPLACE AIR HANDLER AND CONDENSER UNIT AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00318152-I1
02/19/2020
Special inspection requirement — Mechanical Systems
Joseph Bazini
02/19/2020
Special inspection requirement — Final
Joseph Bazini
02/19/2020
Special inspection requirement — HVAC and service water heating equipment
Joseph Bazini
06/04/2019
Violation issued (ECB, closed)
Boilers
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offNULITE FUEL OIL CO., LTD03/18/2022
DOB NOWMechanical SystemsSigned-offNULITE FUEL OIL CO., LTD03/24/2021
DOB NOWMechanical SystemsSigned-offNULITE FUEL OIL CO., LTD09/22/2020
DOB NOWMechanical SystemsSigned-offNULITE FUEL OIL CO., LTD03/20/2020
BIS—ISSUEDVARDO CONSTRUCTION CORP.06/30/1999
BISPLISSUEDJULIAN PLBG & HTG CORP04/16/1999
BIS—ISSUEDVARDO CONSTRUCTION CORP12/01/1998
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
02/19/2020Mechanical SystemsJoseph Bazinispecial
02/19/2020FinalJoseph Baziniprogress
02/19/2020HVAC and service water heating equipment Joseph Bazinienergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/28/2026Q00318152-I1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/23/2026Q00951529-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/23/2026Q00951529-I1Open ↗
08/13/2026Q00318152-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026Q00318152-I1Open ↗
08/26/2026Q00318152-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q00318152-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q00318152-I1Open ↗