← Back
Dormitory
17 GRAMERCY PARK SOUTH
MANHATTAN · Gramercy · BIN 1017937
💬 Discuss this project
1938Year Built
6Stories
H8Building Class
R7BZoning
18,458 sfGross Floor Area
1Units
Rent Stabilized2 Open Violations 0 unresolved · 2 paperwork only ▸FISP: SAFE
Dormitory · Owner of record: SCHOOL OF VISUAL ARTS INC · 4,433 sf lot · 4.16 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Roof5p · 2 filings · 20 docs
Bulkhead1p · 1 filing · 20 docs
Floor 65p · 1 filing · 20 docs
Floor 54p · 1 filing · 20 docs
Floor 42p · 1 filing · 20 docs
Floor 31p · 1 filing · 20 docs
Floor 21p · 1 filing · 20 docs
Floor 19p · 2 filings · 20 docs
Cellar12p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SCHOOL OF VISUAL ARTS3007/08/2026
DAST HOLDING203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SSK ARCHITECTURE, PLLC206/12/2024
EP ENGINEERING LLC705/06/2024
MURRAY ENGINEERING PC203/11/2024
DIRECT ACCESS EXPEDITING, INC209/24/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WALTER T GORMAN PE2003/21/2026
BURNHAM NATIONWIDE INC103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WEST NEW YORK RESTORATION OF CTGeneral Contractor607/08/2026
SPK/LEWIS CONSTRUCTION LLGeneral Contractor407/08/2026
ACE ATLAS CORPORATIONGeneral Contractor203/21/2026
AGGRESSIVE FIRE PROT LLCFire Protection107/08/2026
DPH PLUMBING & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
EP INSPECTIONS AND COMMIS70791106/12/2024
Building Lifecycle
All (113)Filed (13)Permit Issued (10)Signed Off (7)Facade (FISP) (15)Violation (32)Inspection (6)Special Inspection (30)
03/12/2026
Cycle 10 facade report submitted
03/11/2026
Cycle 10 facade report signed — SWARMP
02/27/2026
Cycle 10 facade inspection completed
06/04/2025
Violation issued (HPD, closed)
A
07/15/2024
Signed off — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-S2
06/14/2024
Signed off — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-I1
06/13/2024
Special inspection requirement — Final
Christopher Burgess
06/13/2024
Special inspection requirement — Lighting in dwelling units
Christopher Burgess
06/13/2024
Special inspection requirement — Lighting controls
Christopher Burgess
06/13/2024
Special inspection requirement — Energy Code Compliance Inspections
Christopher Burgess
06/13/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
06/13/2024
Special inspection requirement — Fire-Resistance Rated Construction
Christopher Burgess
06/12/2024
Filed — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-P6
06/10/2024
Special inspection requirement — Final
Christopher Burgess
06/10/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
06/10/2024
Special inspection requirement — Lighting controls
Christopher Burgess
06/10/2024
Special inspection requirement — Lighting in dwelling units
Christopher Burgess
06/10/2024
Special inspection requirement — Fire-Resistance Rated Construction
Christopher Burgess
06/10/2024
Special inspection requirement — Energy Code Compliance Inspections
Christopher Burgess
05/22/2024
Signed off — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-S3
05/09/2024
Special inspection requirement — Post-installed Anchors
Christopher Burgess
05/09/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
05/09/2024
Special inspection requirement — Sprinkler Systems
Christopher Burgess
05/06/2024
Filed — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-P5
05/03/2024
Special inspection requirement — Post-installed Anchors
Christopher Burgess
05/03/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
05/03/2024
Special inspection requirement — Sprinkler Systems
Christopher Burgess
04/22/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/08/2024
Filed — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-P4
04/01/2024
Special inspection requirement — Post-installed Anchors
Christopher Burgess
04/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
04/01/2024
Special inspection requirement — Sprinkler Systems
Christopher Burgess
03/28/2024
Signed off — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-S1
03/28/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/25/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
03/18/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
03/14/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/13/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Christopher Burgess
03/13/2024
Special inspection requirement — Structural Steel - Details
Christopher Burgess
03/13/2024
Special inspection requirement — Final
Christopher Burgess
03/11/2024
Filed — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-P2
03/08/2024
Filed — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-P3
03/06/2024
Special inspection requirement — Sprinkler Systems
Christopher Burgess
03/06/2024
Special inspection requirement — Post-installed Anchors
Christopher Burgess
03/06/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
02/28/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/15/2024
Filed — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-P1
02/09/2024
Special inspection requirement — Post-installed Anchors
Christopher Burgess
02/09/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
02/09/2024
Special inspection requirement — Sprinkler Systems
Christopher Burgess
01/16/2024
Permit issued — Sprinklers
M00981108-S2-PL
01/16/2024
Permit issued — General Construction
M00981108-I1-GC
01/11/2024
Permit issued — Plumbing
M00981108-S2-EW-SP
01/10/2024
Permit issued — Structural
M00981108-S1-ST
01/10/2024
Permit issued — Mechanical Systems
M00981108-S3-MS
01/09/2024
Filed — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-S2
01/09/2024
Filed — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-S3
01/09/2024
Filed — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-S1
01/05/2024
Filed — Alteration
Proposed AC units and associate piping and ducts as per plan. No change of use or occupancy or egress.
M00981108-I1
03/15/2023
Violation issued (HPD, closed)
A
Latest 60 of 113 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offDPH PLUMBING & HTG CORP01/16/2024
DOB NOWGeneral ConstructionSigned-offSPK/LEWIS CONSTRUCTION LL01/16/2024
DOB NOWPlumbingSigned-offAGGRESSIVE FIRE PROT LLC01/11/2024
DOB NOWStructuralSigned-offSPK/LEWIS CONSTRUCTION LL01/10/2024
DOB NOWMechanical SystemsSigned-offSPK/LEWIS CONSTRUCTION LL01/10/2024
DOB NOWMechanical SystemsSigned-offACE ATLAS CORPORATION11/09/2021
DOB NOWSidewalk ShedSigned-offA. PETER LUGER CONST INC04/15/2020
DOB NOWSupported ScaffoldSigned-offA. PETER LUGER CONST INC04/15/2020
DOB NOWSidewalk ShedSigned-offA. PETER LUGER CONST INC09/25/2019
DOB NOWSupported ScaffoldSigned-offA. PETER LUGER CONST INC09/24/2019
BISOTISSUEDWEST NEW YORK RESTORATION OF CT04/21/2020
BISEQISSUEDWEST NEW YORK RESTORATION OF CT09/25/2019
BISOTISSUEDBARNHART RESTORATION & PR08/26/2015
BISOTISSUEDD.P. CONSULTING, CORP07/15/2011
3 projects · most recent 03/25/2024
General Wiring
FiledStatusContractorScope
03/25/2024CompleteR.C.M. ELECTRIC CORP.—
12/20/2023CompleteMETROPOLITAN ELECTRIC COGeneral Wiring
09/10/2019CompleteNASH ELECTRIC SERVICES IN—
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
04/22/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/28/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
03/25/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/18/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/14/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/28/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 50
DateRequirementInspectorRole
06/13/2024FinalChristopher Burgessprogress
06/13/2024Lighting in dwelling unitsChristopher Burgessenergy_progress
06/13/2024Lighting controlsChristopher Burgessenergy_progress
06/13/2024Energy Code Compliance InspectionsChristopher Burgessprogress
06/13/2024Fire-Resistant Penetrations and JointsChristopher Burgessspecial
06/13/2024Fire-Resistance Rated ConstructionChristopher Burgessprogress
06/10/2024FinalChristopher Burgessprogress
06/10/2024Fire-Resistant Penetrations and JointsChristopher Burgessspecial
06/10/2024Lighting controlsChristopher Burgessenergy_progress
06/10/2024Lighting in dwelling unitsChristopher Burgessenergy_progress
06/10/2024Fire-Resistance Rated ConstructionChristopher Burgessprogress
06/10/2024Energy Code Compliance InspectionsChristopher Burgessprogress
05/09/2024Post-installed AnchorsChristopher Burgessspecial
05/09/2024Fire-Resistant Penetrations and JointsChristopher Burgessspecial
05/09/2024Sprinkler SystemsChristopher Burgessspecial
05/03/2024Post-installed AnchorsChristopher Burgessspecial
05/03/2024Fire-Resistant Penetrations and JointsChristopher Burgessspecial
05/03/2024Sprinkler SystemsChristopher Burgessspecial
04/01/2024Post-installed AnchorsChristopher Burgessspecial
04/01/2024Fire-Resistant Penetrations and JointsChristopher Burgessspecial
04/01/2024Sprinkler SystemsChristopher Burgessspecial
03/13/2024Structural Stability – Alterations of existing buildingsChristopher Burgessspecial
03/13/2024Structural Steel - DetailsChristopher Burgessspecial
03/13/2024FinalChristopher Burgessprogress
03/06/2024Sprinkler SystemsChristopher Burgessspecial
Latest 25 of 50.
▾Documents — 128 on file (BIS + DOB NOW)
▸Plans & Drawings13
▸DOB NOWPlans/Sketch11
09/03/2026M00579065-I1Request digital key ↗
08/27/2026M00981108-S3Request digital key ↗
08/27/2026M00981108-P1Request digital key ↗
Showing 3 of 11 on file for this type
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/05/2026M00224304-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/05/2026M00224281-I1Request digital key ↗
▸Applications & Permits22
▸DOB NOWLPC Approval/Permit11
08/13/2026M00981108-P6Open ↗
08/13/2026M00981108-I1Open ↗
08/13/2026M00981108-S2Open ↗
Showing 3 of 11 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION6
08/13/2020123776299Open ↗
08/09/2020123776299Open ↗
08/04/2020123776299Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION5
09/25/2019123802082Open ↗
08/07/2019123776299Open ↗
09/10/2015122475302Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications50
▸DOB NOWProgress Inspector Seal & Signature13
09/01/2026M00981108-I1Open ↗
09/01/2026M00981108-I1Open ↗
08/31/2026M00981108-S3Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature13
09/05/2026M00224281-I1Open ↗
08/13/2026M00981108-P1Open ↗
08/13/2026M00981108-P4Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
09/01/2026M00981108-I1Open ↗
09/01/2026M00981108-P4Open ↗
08/31/2026M00981108-S3Open ↗
Showing 3 of 12 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
09/26/2019123802082Open ↗
07/30/2019123776299Open ↗
07/30/2019123776299Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
09/26/2019123802082Open ↗
07/30/2019123776299Open ↗
09/10/2015122475302Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
09/26/2019123802082Open ↗
07/30/2019123776299Open ↗
09/10/2015122475302Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
09/25/2019123802082Open ↗
▸Environmental & Asbestos14
▸DOB NOWDEP ACP-5: Asbestos Assessment Report11
08/13/2026M00981108-P6Open ↗
08/13/2026M00981108-S1Open ↗
08/13/2026M00981108-I1Open ↗
Showing 3 of 11 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
07/30/2019123776299Open ↗
09/10/2015122475302Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
03/22/2011120635722Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
07/30/2019123776299Open ↗
09/10/2015122475302Open ↗
▸BISAS-BUILT ENERGY ANALYSIS2
08/20/2020123776299Open ↗
11/19/2015122475302Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026M00579065-I1Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY4
08/20/2020123776299Open ↗
08/20/2020123776299Open ↗
08/13/2020123776299Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs9
▸BISLANDMARKS APPROVAL3
07/30/2019123776299Open ↗
09/10/2015122475302Open ↗
05/10/2011120635722Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
10/22/2020123802082Open ↗
08/20/2020123776299Open ↗
11/19/2015122475302Open ↗
▸BISFINAL1
10/22/2020123802082Open ↗
▸BISLANDMARKS SIGNOFF1
08/20/2020123776299Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
03/22/2011120635722Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
08/20/2020123776299Open ↗
07/30/2019123776299Open ↗
11/19/2015122475302Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET4
09/26/2019123802082Open ↗
07/30/2019123776299Open ↗
09/10/2015122475302Open ↗
Showing 3 of 4 on file for this type
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
07/13/2011120635722Open ↗