← Back
Elevator apt, semi-fireproof without stores
Berry (NYCHA)
1700 RICHMOND ROAD · BIN 5109569
💬 Discuss this project
1960Year Built
6Stories
D1Building Class
R5Zoning
448,500 sfGross Floor Area
506Units
3 Open Violations 2 unresolved · 1 paperwork only ▸FISP: No Report FiledFDNY Report ↗
Elevator apt, semi-fireproof without stores · Owner of record: NYC HOUSING AUTHORITY · 483,150 sf lot · 0.93 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 11p · 1 filing · 20 docs
Cellar15p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYCHA1307/08/2026
N.Y.C. HOUSING AUTH.103/22/2026
SULLIVAN CONTRACTING103/21/2026
NYC HOUSING AUTHORITY903/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BAZINI ENGINEERING P C1003/21/2026
MUNICIPAL BUILDING CONSULTANTS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DYNAMIC US, INCGeneral Contractor403/21/2026
RYBURN PHILLIPSElectrical203/21/2026
RIQUE CONSRUCTION INCElectrical103/21/2026
SORTINO JOSEPHElectrical103/21/2026
STEPHENS, KENNETHElectrical103/21/2026
DYNAMIC CONTRACTING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TECTONIC ENGINEERING CONS106406/14/2023
Building Lifecycle
All (90)Filed (6)Permit Issued (3)Signed Off (2)Facade (FISP) (10)Violation (11)Inspection (3)Objection (32)Special Inspection (23)
02/22/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/19/2024
Signed off — Alteration
NYCHA BOILER - BERRY HOUSES, BUILDING 5 - INSTALL NEW CHIMNEY FOR THE EXHAUST VENTS ON THE TWO (2) NEW GAS FIRED HOT WATER HEATERS, AS PER PLANS. INSTALL NEW FIRE RATED DOOR, AND FILL EXISTING WALL OPENINGS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00642541-I1
01/17/2024
Signed off — Alteration
NYCHA BOILER - BERRY HOUSES, BUILDING 5 - DEMOLISH EXISTING STEAM FIRED HOT WATER TANK AND ASSOCIATED PIPING. PROVIDE ALL NEW GAS FIRED HOT WATER HEATER SYSTEM FOR THE EXISTING BUILDING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00642484-I1
08/25/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
08/25/2023
Special inspection requirement — Chimneys and vents
GEORGE GHEBRYAL
08/25/2023
Special inspection requirement — Mechanical Systems
GEORGE GHEBRYAL
08/25/2023
Special inspection requirement — Post-installed Anchors
GEORGE GHEBRYAL
08/25/2023
Special inspection requirement — Final
GEORGE GHEBRYAL
08/25/2023
Special inspection requirement — Energy Code Compliance Inspections
GEORGE GHEBRYAL
08/25/2023
Special inspection requirement — Maintenance information
GEORGE GHEBRYAL
08/25/2023
Special inspection requirement — HVAC-R and service water heating system controls
GEORGE GHEBRYAL
08/25/2023
Special inspection requirement — HVAC-R and service water heating equipment
GEORGE GHEBRYAL
08/25/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
GEORGE GHEBRYAL
08/10/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
08/02/2023
Objection resolved — Addressed
08/02/2023
Objection resolved — Addressed
08/02/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
07/07/2023
Objection raised — Scope
06/14/2023
Filed — Alteration
NYCHA BOILER - BERRY HOUSES, BUILDING 5 - INSTALL NEW CHIMNEY FOR THE EXHAUST VENTS ON THE TWO (2) NEW GAS FIRED HOT WATER HEATERS, AS PER PLANS. INSTALL NEW FIRE RATED DOOR, AND FILL EXISTING WALL OPENINGS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00642541-P1
05/18/2023
Objection raised — Inspections
05/18/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
GEORGE GHEBRYAL
05/18/2023
Special inspection requirement — Chimneys and vents
GEORGE GHEBRYAL
05/18/2023
Special inspection requirement — Mechanical Systems
GEORGE GHEBRYAL
05/18/2023
Special inspection requirement — Post-installed Anchors
GEORGE GHEBRYAL
05/18/2023
Special inspection requirement — Energy Code Compliance Inspections
GEORGE GHEBRYAL
05/18/2023
Special inspection requirement — Final
GEORGE GHEBRYAL
05/18/2023
Special inspection requirement — HVAC-R and service water heating system controls
GEORGE GHEBRYAL
05/18/2023
Special inspection requirement — Maintenance information
GEORGE GHEBRYAL
05/18/2023
Special inspection requirement — HVAC-R and service water heating equipment
GEORGE GHEBRYAL
05/08/2023
Filed — Alteration
NYCHA BOILER - BERRY HOUSES, BUILDING 5 - DEMOLISH EXISTING STEAM FIRED HOT WATER TANK AND ASSOCIATED PIPING. PROVIDE ALL NEW GAS FIRED HOT WATER HEATER SYSTEM FOR THE EXISTING BUILDING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00642484-P2
03/22/2023
Permit issued — General Construction
S00642541-I1-GC-CX
12/01/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/29/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/09/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/31/2022
Filed — Alteration
NYCHA BOILER - BERRY HOUSES, BUILDING 5 - DEMOLISH EXISTING STEAM FIRED HOT WATER TANK AND ASSOCIATED PIPING. PROVIDE ALL NEW GAS FIRED HOT WATER HEATER SYSTEM FOR THE EXISTING BUILDING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00642484-P1
08/17/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
04/21/2022
Permit issued — Plumbing
S00642484-I1-PL
04/21/2022
Permit issued — General Construction
S00642541-I1-GC-CX
02/25/2022
Objection raised — Inspections
02/25/2022
Objection resolved — Addressed
01/28/2022
Filed — Alteration
NYCHA BOILER - BERRY HOUSES, BUILDING 5 - INSTALL NEW CHIMNEY FOR THE EXHAUST VENTS ON THE TWO (2) NEW GAS FIRED HOT WATER HEATERS, AS PER PLANS. INSTALL NEW FIRE RATED DOOR, AND FILL EXISTING WALL OPENINGS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00642541-I1
01/28/2022
Filed — Alteration
NYCHA BOILER - BERRY HOUSES, BUILDING 5 - DEMOLISH EXISTING STEAM FIRED HOT WATER TANK AND ASSOCIATED PIPING. PROVIDE ALL NEW GAS FIRED HOT WATER HEATER SYSTEM FOR THE EXISTING BUILDING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00642484-I1
11/04/2021
Violation issued (FDNY_NOV, closed)
06/10/2021
Violation issued (FDNY_ORDER, closed)
10/27/2020
Objection raised — Structural
10/27/2020
Objection resolved — Addressed
10/27/2020
Objection raised — Fire_Protection
10/27/2020
Objection resolved — Addressed
10/27/2020
Objection raised — Fire_Protection
10/27/2020
Objection resolved — Addressed
10/27/2020
Objection raised — Structural
10/27/2020
Objection resolved — Addressed
10/27/2020
Objection raised — Inspections
10/27/2020
Objection resolved — Addressed
10/27/2020
Objection raised — Structural
10/27/2020
Objection resolved — Addressed
10/27/2020
Objection raised — Fire_Protection
10/27/2020
Objection resolved — Addressed
10/27/2020
Objection raised — Fire_Protection
10/27/2020
Objection resolved — Addressed
Latest 60 of 90 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offDYNAMIC US, INC03/22/2023
DOB NOWPlumbingSigned-offDYNAMIC CONTRACTING CORP04/21/2022
DOB NOWGeneral ConstructionSigned-offDYNAMIC US, INC04/21/2022
BISOTISSUEDA.B.C.D. CONSTRUCTION COR08/20/2015
BISOTISSUEDA.B.C.D. CONSTRUCTION COR06/29/2015
BISEQISSUEDA.B.C.D. CONSTRUCTION COR05/28/2015
BISEQISSUEDA.B.C.D. CONSTRUCTION COR05/28/2015
BISEQISSUEDA.B.C.D. CONSTRUCTION COR04/29/2015
BISEQISSUEDZORIA CONSTRUCTION CORP04/02/2004
BISOTISSUEDV.C. VITANZA SONS, INC.01/31/1994
BISPLISSUEDV. C. VITANZA SONS INC01/31/1994
8 projects · most recent 02/15/2024
General Wiring
FiledStatusContractorScope
02/15/2024CompleteEMENAR ELECL SVCS CONSTGeneral Wiring
11/10/2023CompleteTRI-STATE ELECL & MECHL IGeneral Wiring
11/10/2023CompleteTRI-STATE ELECL & MECHL IGeneral Wiring
05/30/2023CompleteEQUINOX ELECTRIC LLCGeneral Wiring
05/30/2023CompleteEQUINOX ELECTRIC LLCGeneral Wiring
11/29/2021CompleteOHM'S ELECTRICAL CORPGeneral Wiring
09/12/2020Permit IssuedN.Y.C. HOUSING AUTHORITYGeneral Wiring
09/12/2020Permit IssuedN.Y.C. HOUSING AUTHORITYGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
12/01/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/29/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/09/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
08/25/2023Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
08/25/2023Chimneys and ventsGEORGE GHEBRYALspecial
08/25/2023Mechanical SystemsGEORGE GHEBRYALspecial
08/25/2023Post-installed AnchorsGEORGE GHEBRYALspecial
08/25/2023FinalGEORGE GHEBRYALprogress
08/25/2023Energy Code Compliance InspectionsGEORGE GHEBRYALprogress
08/25/2023Maintenance informationGEORGE GHEBRYALenergy_progress
08/25/2023HVAC-R and service water heating system controlsGEORGE GHEBRYALenergy_progress
08/25/2023HVAC-R and service water heating equipmentGEORGE GHEBRYALenergy_progress
08/25/2023HVAC-R and service water piping design and insulationGEORGE GHEBRYALenergy_progress
08/10/2023Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
08/02/2023Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
05/18/2023HVAC-R and service water piping design and insulationGEORGE GHEBRYALenergy_progress
05/18/2023Chimneys and ventsGEORGE GHEBRYALspecial
05/18/2023Mechanical SystemsGEORGE GHEBRYALspecial
05/18/2023Post-installed AnchorsGEORGE GHEBRYALspecial
05/18/2023Energy Code Compliance InspectionsGEORGE GHEBRYALprogress
05/18/2023FinalGEORGE GHEBRYALprogress
05/18/2023HVAC-R and service water heating system controlsGEORGE GHEBRYALenergy_progress
05/18/2023Maintenance informationGEORGE GHEBRYALenergy_progress
05/18/2023HVAC-R and service water heating equipmentGEORGE GHEBRYALenergy_progress
08/17/2022Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
09/18/2020Public Assembly Emergency Lighting—progress
▾Documents — 112 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch5
08/24/2026S00642484-P1Request digital key ↗
08/24/2026S00642484-I1Request digital key ↗
08/15/2026S00642541-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Place of Assembly1
08/15/2026S00401401-I1Request digital key ↗
▸Applications & Permits12
▸BISWORK PERMIT APPLICATION6
08/21/2015540040917Open ↗
06/29/2015540040917Open ↗
05/27/2015540078208Open ↗
Showing 3 of 6 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION5
05/27/2015540078208Open ↗
05/27/2015540078191Open ↗
04/30/2015520242844Open ↗
Showing 3 of 5 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
06/29/2015540040917Open ↗
▸Seals & Professional Certifications44
▸DOB NOWProgress Inspector Seal & Signature12
09/01/2026S00642541-I1Open ↗
09/01/2026S00642541-I1Open ↗
09/01/2026S00642541-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/01/2026S00642541-I1Open ↗
09/01/2026S00642541-I1Open ↗
09/01/2026S00642541-I1Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
04/06/2016540040917Open ↗
04/06/2016540040917Open ↗
02/12/2016520242844Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/13/2026S00642541-P1Open ↗
08/13/2026S00642484-P1Open ↗
08/13/2026S00401401-I1Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
05/27/2015540078208Open ↗
05/27/2015540078191Open ↗
04/30/2015520242844Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY4
05/27/2015540078208Open ↗
05/27/2015540078191Open ↗
03/27/2014540040917Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
05/27/2015540078208Open ↗
05/27/2015540078191Open ↗
03/27/2014540040917Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
04/30/2015520242844Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
07/31/2007510011318Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN 2008 CODE1
03/27/2014540040917Open ↗
▸Environmental & Asbestos6
▸BISDEP ASBESTOS PROJECT COMPLETION FORM2
06/03/2016540040917Open ↗
05/25/2016540040917Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/13/2026S00642484-I1Open ↗
08/13/2026S00642541-I1Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
03/27/2014540040917Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
07/31/2007510011318Open ↗
▸Energy Compliance11
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
09/11/2014540040917Open ↗
08/29/2014540040917Open ↗
03/27/2014540040917Open ↗
▸DOB NOWPreliminary Commissioning Report Certification2
08/13/2026S00642484-I1Open ↗
08/13/2026S00642541-I1Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
03/27/2014540040917Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
04/06/2016540040917Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
04/06/2016540040917Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
05/27/2015540078191Open ↗
▸BISNYCECC ANALYSIS1
03/27/2014540040917Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026S00642541-I1Open ↗
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY7
05/27/2015540078208Open ↗
05/27/2015540078191Open ↗
09/11/2014540040917Open ↗
Showing 3 of 7 on file for this type
▸Approvals, Objections & Sign-offs16
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter6
08/13/2026S00401401-I1Open ↗
08/13/2026S00642541-P1Open ↗
08/13/2026S00642484-I1Open ↗
Showing 3 of 6 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
06/03/2016540040917Open ↗
04/06/2016540040917Open ↗
02/12/2016520242844Open ↗
Showing 3 of 5 on file for this type
▸BISADMINISTRATIVE OBJECTIONS2
04/30/2015520242844Open ↗
08/02/2007510011318Open ↗
▸DOB NOWDEP Variance (V5) letter2
08/13/2026S00642484-I1Open ↗
08/13/2026S00642541-I1Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
04/30/2015520242844Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
04/06/2016540040917Open ↗
03/27/2014540040917Open ↗
▸Filing & Intake Forms5
▸BISEFILING JOB APPLICATION COVER SHEET3
05/27/2015540078208Open ↗
05/27/2015540078191Open ↗
03/27/2014540040917Open ↗
▸BISADDITIONAL INFORMATION1
03/27/2014540040917Open ↗
▸BISEFILING COVER SHEET1
04/30/2015520242844Open ↗
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
04/30/2015520242844Open ↗