← Back
Three families
171-40 109 AVENUE
QUEENS · South Jamaica · BIN 4218723
💬 Discuss this project
1925Year Built
2.75Stories
C0Building Class
R4Zoning
1,964 sfGross Floor Area
3Units
7 Open Violations ▸FDNY Report ↗
Three families · 3,519 sf lot · 0.56 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 7 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC112/24/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S R SOLAR DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HYTECH SOLAR INCGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244112/24/2025
Building Lifecycle
All (21)Filed (1)Permit Issued (1)Signed Off (1)Violation (13)Special Inspection (5)
05/12/2026
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
Q01331167-I1
12/30/2025
Permit issued — Solar
Q01331167-I1-SL
12/24/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
Q01331167-I1
12/09/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
12/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
12/09/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
12/09/2025
Special inspection requirement — Final
NARESH MAHANGU
12/09/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
02/26/2018
Violation issued (HPD, open)
B
02/26/2018
Violation issued (HPD, open)
C
02/26/2018
Violation issued (HPD, open)
B
02/26/2018
Violation issued (HPD, open)
B
02/26/2018
Violation issued (HPD, open)
C
02/26/2018
Violation issued (HPD, closed)
C
02/26/2018
Violation issued (HPD, open)
C
02/26/2018
Violation issued (HPD, open)
B
12/29/2017
Violation issued (ECB, closed)
Construction
10/31/2017
Violation issued (ECB, closed)
Construction
10/31/2017
Violation issued (ECB, closed)
Quality of Life
07/30/2003
Violation issued (ECB, closed)
Quality of Life
07/30/2003
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offHYTECH SOLAR12/30/2025
1 project · most recent 12/10/2025
FiledStatusContractorScope
12/10/2025CompleteGMJ ELECTRIC CORP—
1 project · most recent 12/24/2025
FiledStatusContractorScope
12/24/2025Signed-offHYTECH SOLAR INC24 panels, 10.56 kw, 516 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
12/09/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
12/09/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
12/09/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
12/09/2025FinalNARESH MAHANGUprogress
12/09/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026Q01331167-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026Q01331167-I1Open ↗
08/27/2026Q01331167-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/18/2026Q01331167-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026Q01331167-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/18/2026Q01331167-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01331167-I1Open ↗