← Back
Walk-up apt, over six families with stores
1712 2 AVENUE
MANHATTAN · BIN 1050101
💬 Discuss this project
1915Year Built
5Stories
C7Building Class
C2-8Zoning
10,000 sfGross Floor Area
13Units
Rent Stabilized42 Open Violations ▸FDNY Report ↗
Walk-up apt, over six families with stores · Owner of record: 88TH REALTY INC · 2,500 sf lot · 4 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Roof1p · 1 filing · 11 docs
Floor 16p · 1 filing · 20 docs
Cellar7p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
J G CONSTRUCTION SRVCS807/08/2026
88TH REALTY INC C O TINGS BROKERAGE207/08/2026
CORP 88TH REALITY1803/22/2026
88 REALTY803/22/2026
THE OWNER OF103/22/2026
OWNER OF 1712 2 ND103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SYED ENGINEERING, P.C.306/21/2022
JUNG H. CHOI, ARCHITECT, PC711/10/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
YBL NY1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
QUICK REFRIGERATION & HEAGeneral Contractor303/21/2026
HORBRIDGE PLUMBING & HEATINGPlumbing207/08/2026
LAWRENCE NELSONElectrical103/21/2026
J & G CONSTRUCTION SVCSGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JUNG H CHOI ARCHITECT3020711/10/2021
Building Lifecycle
All (93)Filed (10)Permit Issued (4)Signed Off (1)Violation (60)Inspection (1)Special Inspection (17)
04/18/2025
Violation issued (FDNY_NOV, closed)
04/18/2025
Violation issued (FDNY_NOV, closed)
04/18/2025
Violation issued (FDNY_ORDER, closed)
04/01/2024
Violation issued (HPD, closed)
A
11/03/2023
Violation issued (FDNY_NOV, closed)
03/15/2023
Violation issued (HPD, closed)
A
12/23/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/21/2022
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M00211720-P1
02/15/2022
Violation issued (HPD, closed)
I
02/15/2022
Violation issued (HPD, closed)
A
11/12/2021
Special inspection requirement — Energy Code Compliance Inspections
Jung Choi
11/12/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jung Choi
11/10/2021
Filed — Alteration
REPLACEMENT OF EXISTING KITCHEN EQUIPMENT & PLUMBING FIXTURES INSTALLED UNDER JOB# 100196002 DUE TO FIRE DAMAGE AS PER PLAN. THERE IS NO CHANGE IN USE, OCCUPANCY, OR MEANS OF EGRESS UNDER THIS APPLICATION.
M00372382-P7
11/10/2021
Special inspection requirement — Energy Code Compliance Inspections
Jung Choi
11/10/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jung Choi
11/05/2021
Filed — Alteration
REPLACEMENT OF EXISTING KITCHEN EQUIPMENT & PLUMBING FIXTURES INSTALLED UNDER JOB# 100196002 DUE TO FIRE DAMAGE AS PER PLAN. THERE IS NO CHANGE IN USE, OCCUPANCY, OR MEANS OF EGRESS UNDER THIS APPLICATION.
M00372382-P6
11/01/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jung Choi
11/01/2021
Special inspection requirement — Energy Code Compliance Inspections
Jung Choi
09/28/2021
Permit issued — Plumbing
M00372382-I1-PL
09/16/2021
Signed off — Alteration
INSTALLING NEW (1) HVAC UNIT, (2) WALK-IN FREEZER BOXES, KITCHEN HOOD, EXHAUST DUCT AND OBTAIN NEW EQUIPMENT USE PERMIT CARD AS PER PLAN. THERE IS NO CHANGE IN USE, OCCUPANCY, OR MEANS OF EGRESS UNDER THIS APPLICATION.
M00375306-I1
04/01/2021
Violation issued (HPD, closed)
A
02/19/2021
Filed — Alteration
REPLACEMENT OF EXISTING KITCHEN EQUIPMENT & PLUMBING FIXTURES INSTALLED UNDER JOB# 100196002 DUE TO FIRE DAMAGE AS PER PLAN. THERE IS NO CHANGE IN USE, OCCUPANCY, OR MEANS OF EGRESS UNDER THIS APPLICATION.
M00372382-P5
11/17/2020
Violation issued (ECB, closed)
Construction
10/02/2020
Filed — Alteration
REPLACEMENT OF EXISTING KITCHEN EQUIPMENT & PLUMBING FIXTURES INSTALLED UNDER JOB# 100196002 DUE TO FIRE DAMAGE AS PER PLAN. THERE IS NO CHANGE IN USE, OCCUPANCY, OR MEANS OF EGRESS UNDER THIS APPLICATION.
M00372382-P4
10/02/2020
Special inspection requirement — Energy Code Compliance Inspections
Jung Choi
10/02/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jung Choi
08/18/2020
Filed — Alteration
REPLACEMENT OF EXISTING KITCHEN EQUIPMENT & PLUMBING FIXTURES INSTALLED UNDER JOB# 100196002 DUE TO FIRE DAMAGE AS PER PLAN. THERE IS NO CHANGE IN USE, OCCUPANCY, OR MEANS OF EGRESS UNDER THIS APPLICATION.
M00372382-P1
08/17/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jung Choi
08/17/2020
Special inspection requirement — Energy Code Compliance Inspections
Jung Choi
07/28/2020
Permit issued — Mechanical Systems
M00375306-I1-MS
07/27/2020
Filed — Alteration
INSTALLING NEW (1) HVAC UNIT, (2) WALK-IN FREEZER BOXES, KITCHEN HOOD, EXHAUST DUCT AND OBTAIN NEW EQUIPMENT USE PERMIT CARD AS PER PLAN. THERE IS NO CHANGE IN USE, OCCUPANCY, OR MEANS OF EGRESS UNDER THIS APPLICATION.
M00375306-I1
07/23/2020
Special inspection requirement — Fire-Resistance Rated Construction
Jung Choi
07/23/2020
Special inspection requirement — Energy Code Compliance Inspections
Jung Choi
07/23/2020
Special inspection requirement — Final
Jung Choi
07/23/2020
Special inspection requirement — Mechanical Systems
Jung Choi
07/23/2020
Special inspection requirement — HVAC and service water heating system controls
Jung Choi
07/23/2020
Special inspection requirement — Maintenance information
Jung Choi
07/23/2020
Special inspection requirement — HVAC and service water heating equipment
Jung Choi
07/21/2020
Permit issued — Plumbing
M00372382-I1-PL
07/17/2020
Filed — Alteration
REPLACEMENT OF EXISTING KITCHEN EQUIPMENT & PLUMBING FIXTURES INSTALLED UNDER JOB# 100196002 DUE TO FIRE DAMAGE AS PER PLAN. THERE IS NO CHANGE IN USE, OCCUPANCY, OR MEANS OF EGRESS UNDER THIS APPLICATION.
M00372382-I1
09/15/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/04/2019
Violation issued (HPD, closed)
B
08/26/2019
Filed — Alteration
M00211728-I1
08/26/2019
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M00211720-I1
08/26/2019
Permit issued — Sidewalk Shed
M00211720-I1-SH
04/30/2019
Violation issued (HPD, closed)
C
10/05/2018
Violation issued (HPD, closed)
I
01/08/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/08/2017
Violation issued (HPD, open)
B
10/01/2015
Violation issued (HPD, closed)
I
01/28/2015
Violation issued (HPD, closed)
B
04/16/2012
Violation issued (FDNY_ORDER, closed)
10/03/2007
Violation issued (HPD, open)
B
10/03/2007
Violation issued (HPD, open)
B
10/03/2007
Violation issued (HPD, open)
B
10/03/2007
Violation issued (HPD, open)
B
04/12/2007
Violation issued (HPD, open)
B
04/12/2007
Violation issued (HPD, open)
B
04/12/2007
Violation issued (HPD, open)
B
04/12/2007
Violation issued (HPD, open)
B
Latest 60 of 93 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedHORBRIDGE PLUMBING & HEAT09/28/2021
DOB NOWMechanical SystemsSigned-offQUICK REFRIGERATION & HEA07/28/2020
DOB NOWPlumbingPermit IssuedHORBRIDGE PLUMBING & HEAT07/21/2020
DOB NOWSidewalk ShedPermit IssuedJ & G CONSTRUCTION SVCS08/26/2019
BISOTISSUEDSUPERIOR DESIGN CONSTRUCT11/24/2020
BISOTISSUEDJ & M STRONGWATER LLC10/21/2019
BISMHISSUEDJSL DESIGN INC06/09/2017
BISPLISSUEDPLUMBING & HTG DOCTOR INC06/05/2017
BISOTISSUEDJSL DESIGN INC11/16/2016
BISPLISSUEDDYCKMAN PLBG AND HTG INC10/12/2010
BISOTISSUEDSCK TEAM WORK CORP10/08/2010
BISBLISSUEDBLUE DIAMOND FUEL OIL COR06/16/2009
BISBLISSUEDBAYSIDE FUEL12/22/2008
BISPLISSUEDDYCHMAN PLUMBING & HEATING INC05/22/2008
BISOTISSUEDSCK TEAM WORK CORP08/21/2007
BISPLISSUEDB.H. PLUMBING&HTG CORP.04/18/2007
BISOTISSUEDSCK TEAM WORK CORP03/29/2007
BISPLISSUEDS & L PLUMBING INC01/09/2006
BISOTISSUEDG.A.WALKER INCDRFTNG EXPDNG SERV07/12/2000
BISFPISSUEDIDEAL FIRE CONTROL INC.02/17/2000
BISOTISSUEDCHINATOWN PLG & HTG INC09/23/1998
BISPLISSUEDCHINATOWN PLBG & HTG INC09/03/1998
BISOTISSUEDAUSTRALIA LP06/21/1996
BISBLISSUEDDUO COLONY FUEL CORP06/09/1995
BIS—ISSUEDL.S. SIGN CO. INC.03/14/1995
BISPLISSUEDJ. CAIAZZO PLBG & HTG COR11/07/1994
BISOTISSUEDXLT CONSTRUCTION CORP.10/18/1994
BISMHISSUEDXLT CONSTRUCTION CORP.08/31/1994
1 project · most recent 11/10/2021
Gas Water/Sanitary
FiledStatusContractorScope
11/10/2021Permit IssuedHORBRIDGE PLUMBING & HEATGas, Water/Sanitary
3 projects · most recent 08/05/2021
General Wiring
FiledStatusContractorScope
08/05/2021CompleteAERO ELECTRIC CORPGeneral Wiring
01/14/2020CompletePROSCIA ELECTL CONTRNG IN—
08/26/2019Permit IssuedRICHARD NEU—
1 project · most recent 06/21/2022
Sidewalk Shed
FiledStatusContractorScope
06/21/2022Permit IssuedJ & G CONSTRUCTION SRVCSSidewalk Shed
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
12/23/2022Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
11/12/2021Energy Code Compliance InspectionsJung Choiprogress
11/12/2021Fire-Resistant Penetrations and JointsJung Choispecial
11/10/2021Energy Code Compliance InspectionsJung Choiprogress
11/10/2021Fire-Resistant Penetrations and JointsJung Choispecial
11/01/2021Fire-Resistant Penetrations and JointsJung Choispecial
11/01/2021Energy Code Compliance InspectionsJung Choiprogress
10/02/2020Energy Code Compliance InspectionsJung Choiprogress
10/02/2020Fire-Resistant Penetrations and JointsJung Choispecial
08/17/2020Fire-Resistant Penetrations and JointsJung Choispecial
08/17/2020Energy Code Compliance InspectionsJung Choiprogress
07/23/2020Fire-Resistance Rated ConstructionJung Choiprogress
07/23/2020Energy Code Compliance InspectionsJung Choiprogress
07/23/2020FinalJung Choiprogress
07/23/2020Mechanical SystemsJung Choispecial
07/23/2020HVAC and service water heating system controls Jung Choienergy_progress
07/23/2020Maintenance informationJung Choienergy_progress
07/23/2020HVAC and service water heating equipment Jung Choienergy_progress
▾Documents — 153 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch - Plumbing6
09/03/2026M00372382-P6Request digital key ↗
09/03/2026M00372382-I1Request digital key ↗
08/15/2026M00372382-P7Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed2
09/05/2026M00211720-I1Request digital key ↗
09/05/2026M00211720-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/04/2026M00375306-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/05/2026M00211728-I1Request digital key ↗
▸Applications & Permits23
▸BISPLAN / WORK APPROVAL APPLICATION13
07/23/2020140926130Open ↗
10/18/2019140873302Open ↗
04/20/2018140573225Open ↗
Showing 3 of 13 on file for this type
▸BISWORK PERMIT APPLICATION10
11/24/2020140926130Open ↗
10/18/2019140873302Open ↗
06/05/2017140573225Open ↗
Showing 3 of 10 on file for this type
▸Seals & Professional Certifications43
▸DOB NOWProgress Inspector Seal & Signature11
09/02/2026M00372382-P4Open ↗
08/30/2026M00375306-I1Open ↗
08/30/2026M00375306-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
09/05/2026M00211720-I1Open ↗
09/05/2026M00211720-P1Open ↗
09/05/2026M00211728-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/02/2026M00372382-P4Open ↗
08/30/2026M00372382-P1Open ↗
08/30/2026M00375306-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
04/26/2018140573225Open ↗
04/26/2018140573225Open ↗
04/18/2018140573225Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
07/23/2020140926130Open ↗
10/18/2019140873302Open ↗
11/15/2016140573225Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
05/26/2009120049296Open ↗
12/16/2008110413035Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
10/18/2019140873302Open ↗
11/15/2016140573225Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
10/18/2019140873302Open ↗
11/15/2016140573225Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
05/26/2009120049296Open ↗
12/16/2008110413035Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
07/23/2020140926130Open ↗
▸Trade Schedules & Equipment8
▸BISSELF-CERT PLUMBING NOTICE3
02/28/2011120432816Open ↗
01/07/2011120432816Open ↗
12/01/2010120432816Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
05/26/2009120049296Open ↗
12/16/2008110413035Open ↗
▸BISSCHEDULE B - PLUMBING2
11/15/2016140573225Open ↗
08/09/2010120432816Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
04/12/2018140573225Open ↗
▸Safety & Tenant Protection10
▸DOB NOWTenant Protection Plan7
08/13/2026M00372382-P6Open ↗
08/13/2026M00372382-P4Open ↗
08/13/2026M00372382-I1Open ↗
Showing 3 of 7 on file for this type
▸BISTENANT PROTECTION PLAN AND NOTES3
04/16/2021140926130Open ↗
10/18/2019140873302Open ↗
11/15/2016140573225Open ↗
▸Environmental & Asbestos13
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
09/03/2026M00372382-P5Open ↗
09/03/2026M00372382-P4Open ↗
09/03/2026M00372382-P1Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
07/23/2020140926130Open ↗
10/18/2019140873302Open ↗
11/15/2016140573225Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
08/09/2010120432816Open ↗
05/26/2009120049296Open ↗
12/16/2008110413035Open ↗
▸Energy Compliance10
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
11/27/2020140873302Open ↗
07/23/2020140926130Open ↗
10/18/2019140873302Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS3
07/23/2020140926130Open ↗
10/18/2019140873302Open ↗
11/15/2016140573225Open ↗
▸BISAS-BUILT ENERGY ANALYSIS2
11/27/2020140873302Open ↗
04/26/2018140573225Open ↗
▸BISNYCECC ANALYSIS1
10/18/2019140873302Open ↗
▸Inspections & Test Reports6
▸BISTECHNICAL REPORT: RESPONSIBILITY6
11/27/2020140873302Open ↗
11/27/2020140873302Open ↗
07/23/2020140926130Open ↗
Showing 3 of 6 on file for this type
▸Approvals, Objections & Sign-offs7
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
11/27/2020140873302Open ↗
04/26/2018140573225Open ↗
01/11/2013120049296Open ↗
▸BISADMINISTRATIVE OBJECTIONS3
08/09/2010120432816Open ↗
05/26/2009120049296Open ↗
12/16/2008110413035Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
06/20/2017140573225Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
11/27/2020140873302Open ↗
07/23/2020140926130Open ↗
10/18/2019140873302Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms17
▸BISADDITIONAL INFORMATION9
07/30/2020140926130Open ↗
07/30/2020140926130Open ↗
11/27/2019140873302Open ↗
Showing 3 of 9 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
07/23/2020140926130Open ↗
10/18/2019140873302Open ↗
11/15/2016140573225Open ↗
▸BISEFILING COVER SHEET3
08/09/2010120432816Open ↗
05/26/2009120049296Open ↗
12/16/2008110413035Open ↗
▸BISBOROUGH INTAKE FORM2
04/26/2018140573225Open ↗
04/16/2018140573225Open ↗