← Back
Five to six families
1713 PUTNAM AVENUE
QUEENS · Ridgewood · BIN 4082718
💬 Discuss this project
1930Year Built
3Stories
C2Building Class
R6BZoning
5,600 sfGross Floor Area
6Units
Rent Stabilized3 Open Violations ▸
Five to six families · Owner of record: BATH 2046 LLC · 2,742 sf lot · 2.04 FAR built · Flood zone X
Locations of Work
Architecture
Bulkhead3p · 1 filing · 20 docs
Floor 31p · 1 filing · 20 docs
Floor 2
Floor 1
Cellar1p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
12 METRO LLC1703/22/2026
BATH 2046 LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/22/2022$2.8M—Private party → BATH 2046 LLC$491/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CX CONSULTING CORP506/27/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
STUDIO HUASHI1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRESTIGE TEAM WORK INCGeneral Contractor603/21/2026
TRI STATE PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
XC ENGINEERING PC6692506/27/2023
Building Lifecycle
All (59)Filed (5)Permit Issued (3)Signed Off (3)Violation (30)Inspection (5)Special Inspection (13)
05/07/2026
Violation issued (HPD, open)
A
11/14/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/12/2025
Violation issued (HPD, closed)
A
11/08/2024
Violation issued (HPD, open)
B
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/02/2024
Violation issued (HPD, open)
B
06/02/2024
Violation issued (HPD, closed)
A
06/02/2024
Violation issued (HPD, closed)
C
06/02/2024
Violation issued (HPD, closed)
A
06/02/2024
Violation issued (HPD, closed)
A
06/02/2024
Violation issued (HPD, closed)
A
06/02/2024
Violation issued (HPD, closed)
A
06/02/2024
Violation issued (HPD, closed)
A
04/16/2024
Violation issued (HPD, closed)
A
01/18/2024
Signed off — Alteration
INSTALL HEATING AND AIR CONDITIONING SYSTEMS AT EXISTING CELLAR, APT 1L, 1R ON 1ST FLOOR, APT 2L, 2R, 2F ON 2ND FLOOR, APT 3L, 3R, 3F ON 3RD FLOOR. NO CHANGE TO USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
Q08031525-S1
01/18/2024
Signed off — Alteration
INSTALL HEATING AND AIR CONDITIONING SYSTEMS AT EXISTING CELLAR, APT 1L, 1R ON 1ST FLOOR, APT 2L, 2R, 2F ON 2ND FLOOR, APT 3L, 3R, 3F ON 3RD FLOOR. NO CHANGE TO USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
Q08031525-S2
01/18/2024
Signed off — Alteration
INSTALL HEATING AND AIR CONDITIONING SYSTEMS AT EXISTING CELLAR, APT 1L, 1R ON 1ST FLOOR, APT 2L, 2R, 2F ON 2ND FLOOR, APT 3L, 3R, 3F ON 3RD FLOOR. NO CHANGE TO USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
Q08031525-I1
08/03/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
07/01/2023
Permit issued — Mechanical Systems
Q08031525-S2-MS
06/27/2023
Filed — Alteration
INSTALL HEATING AND AIR CONDITIONING SYSTEMS AT EXISTING CELLAR, APT 1L, 1R ON 1ST FLOOR, APT 2L, 2R, 2F ON 2ND FLOOR, APT 3L, 3R, 3F ON 3RD FLOOR. NO CHANGE TO USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
Q08031525-S2
06/21/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIU CHEN
06/21/2023
Special inspection requirement — Energy Code Compliance Inspections
XIU CHEN
06/21/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
XIU CHEN
06/21/2023
Special inspection requirement — HVAC-R and service water heating equipment
XIU CHEN
06/21/2023
Special inspection requirement — HVAC-R and service water heating system controls
XIU CHEN
06/17/2023
Filed — Alteration
INSTALL HEATING AND AIR CONDITIONING SYSTEMS AT EXISTING CELLAR, APT 1L, 1R ON 1ST FLOOR, APT 2L, 2R, 2F ON 2ND FLOOR, APT 3L, 3R, 3F ON 3RD FLOOR. NO CHANGE TO USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
Q08031525-P2
06/07/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/07/2023
Special inspection requirement — HVAC-R and service water heating system controls
XIU CHEN
06/07/2023
Special inspection requirement — Energy Code Compliance Inspections
XIU CHEN
06/07/2023
Special inspection requirement — HVAC-R and service water heating equipment
XIU CHEN
06/07/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
XIU CHEN
06/07/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIU CHEN
05/15/2023
Filed — Alteration
INSTALL HEATING AND AIR CONDITIONING SYSTEMS AT EXISTING CELLAR, APT 1L, 1R ON 1ST FLOOR, APT 2L, 2R, 2F ON 2ND FLOOR, APT 3L, 3R, 3F ON 3RD FLOOR. NO CHANGE TO USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
Q08031525-P1
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/29/2023
Violation issued (HPD, closed)
A
02/17/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/17/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/15/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/31/2023
Permit issued — Plumbing
Q08031525-S1-PL
01/26/2023
Filed — Alteration
INSTALL HEATING AND AIR CONDITIONING SYSTEMS AT EXISTING CELLAR, APT 1L, 1R ON 1ST FLOOR, APT 2L, 2R, 2F ON 2ND FLOOR, APT 3L, 3R, 3F ON 3RD FLOOR. NO CHANGE TO USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
Q08031525-S1
11/21/2022
Permit issued — General Construction
Q08031525-I1-GC
11/13/2022
Filed — Alteration
INSTALL HEATING AND AIR CONDITIONING SYSTEMS AT EXISTING CELLAR, APT 1L, 1R ON 1ST FLOOR, APT 2L, 2R, 2F ON 2ND FLOOR, APT 3L, 3R, 3F ON 3RD FLOOR. NO CHANGE TO USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
Q08031525-I1
11/01/2022
Special inspection requirement — Energy Code Compliance Inspections
XIU CHEN
11/01/2022
Special inspection requirement — Fire-Resistance Rated Construction
XIU CHEN
11/01/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIU CHEN
06/08/2022
Violation issued (HPD, closed)
A
06/08/2022
Violation issued (HPD, closed)
A
04/16/2021
Violation issued (HPD, closed)
I
04/16/2021
Violation issued (HPD, closed)
A
11/01/2019
Violation issued (HPD, closed)
I
10/24/2018
Violation issued (HPD, closed)
I
11/22/2016
Violation issued (HPD, closed)
I
05/28/2016
Violation issued (HPD, closed)
B
03/01/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/16/2007
Violation issued (ECB, closed)
Quality of Life
01/16/2007
Violation issued (ECB, closed)
Quality of Life
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/31/1991
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offPRESTIGE TEAM WORK INC07/01/2023
DOB NOWPlumbingSigned-offDW PLUMBING INC01/31/2023
DOB NOWGeneral ConstructionSigned-offPRESTIGE TEAM WORK INC11/21/2022
BISPLISSUEDORBIT PLBG & HTG INC12/14/2010
BIS—ISSUEDA INTERNATIONAL LTD12/10/2010
BISPLISSUEDORBIT PLBG & HTG INC02/27/2009
BIS—ISSUEDA INTERNATIONAL LTD02/20/2009
1 project · most recent 06/27/2023
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/27/2023Signed-offPRESTIGE TEAM WORK INCHeating and Air Conditioning Systems
Heat / Cool
Gree CAS12HP230V1AC 12,000 BTU · Vrf Indoor ×32
MULTI30HP230V1CO 30,000 BTU · Condensing Unit ×4
MULTI36HP230V1CO 36,000 BTU · Condensing Unit ×4
LIVV09HP230V1AO 9,000 BTU · Condensing Unit ×2
1 project · most recent 06/27/2023
Gas Water/Sanitary
FiledStatusContractorScope
06/27/2023Signed-offTRI STATE PLBG & HTG INCGas, Water/Sanitary
1 project · most recent 05/09/2023
General Wiring
FiledStatusContractorScope
05/09/2023CompleteKYL ELECTRIC LLCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/03/2023Pass-Final General Construction Non-Directive 14PassView ↗
06/07/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/17/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/17/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/15/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
06/21/2023Fire-Resistant Penetrations and JointsXIU CHENspecial
06/21/2023Energy Code Compliance InspectionsXIU CHENprogress
06/21/2023HVAC-R and service water piping design and insulationXIU CHENenergy_progress
06/21/2023HVAC-R and service water heating equipmentXIU CHENenergy_progress
06/21/2023HVAC-R and service water heating system controlsXIU CHENenergy_progress
06/07/2023HVAC-R and service water heating system controlsXIU CHENenergy_progress
06/07/2023Energy Code Compliance InspectionsXIU CHENprogress
06/07/2023HVAC-R and service water heating equipmentXIU CHENenergy_progress
06/07/2023HVAC-R and service water piping design and insulationXIU CHENenergy_progress
06/07/2023Fire-Resistant Penetrations and JointsXIU CHENspecial
11/01/2022Energy Code Compliance InspectionsXIU CHENprogress
11/01/2022Fire-Resistance Rated ConstructionXIU CHENprogress
11/01/2022Fire-Resistant Penetrations and JointsXIU CHENspecial
▾Documents — 58 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/25/2026Q08031525-P2Request digital key ↗
08/25/2026Q08031525-P1Request digital key ↗
08/25/2026Q08031525-S1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION4
04/30/2009410212176Open ↗
02/26/2009410212176Open ↗
01/30/2009410212176Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION3
12/10/2010410212176Open ↗
02/27/2009410212176Open ↗
02/21/2009410212176Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION2
08/19/2011410212176Open ↗
12/16/2010410212176Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISTAX LOT- TENTATIVE LOT NUMBER ISSUED1
08/17/2011410212176Open ↗
▸Seals & Professional Certifications15
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/25/2026Q08031525-P1Open ↗
08/25/2026Q08031525-S1Open ↗
08/25/2026Q08031525-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/28/2026Q08031525-I1Open ↗
08/27/2026Q08031525-P2Open ↗
08/27/2026Q08031525-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/28/2026Q08031525-I1Open ↗
08/27/2026Q08031525-P2Open ↗
08/25/2026Q08031525-S1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
08/19/2011410212176Open ↗
02/21/2009410212176Open ↗
▸Trade Schedules & Equipment11
▸BISSCHEDULE B - PLUMBING5
04/30/2009410212176Open ↗
02/27/2009410212176Open ↗
02/26/2009410212176Open ↗
Showing 3 of 5 on file for this type
▸BISSELF-CERT PLUMBING NOTICE4
07/20/2011410212176Open ↗
06/28/2011410212176Open ↗
06/13/2011410212176Open ↗
Showing 3 of 4 on file for this type
▸BISDETECTOR:SMOKE-CERTIFICATE OF INSTALLATION2
08/17/2011410212176Open ↗
08/17/2011410212176Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/25/2026Q08031525-P1Open ↗
08/25/2026Q08031525-S1Open ↗
08/25/2026Q08031525-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
01/09/2009410212176Open ↗
▸Approvals, Objections & Sign-offs6
▸BISSCHEDULE A - OCCUPANCY / USE3
08/31/2011410212176Open ↗
02/06/2009410212176Open ↗
01/09/2009410212176Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
01/09/2009410212176Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
08/17/2011410212176Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
08/31/2011410212176Open ↗
▸Cost, Insurance & Ownership2
▸BISDEPT OF FINANCE VERIFICATION1
08/19/2011410212176Open ↗
▸BISCOST AFFIDAVIT1
08/17/2011410212176Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
08/19/2011410212176Open ↗
▸BISEFILING COVER SHEET1
01/09/2009410212176Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
01/09/2009410212176Open ↗