← Back
Miscellaneous two family
1719 WATSON AVENUE
BRONX · BIN 2092822
💬 Discuss this project
1955Year Built
3Stories
B9Building Class
R6Zoning
2,860 sfGross Floor Area
2Units
0 Open Violations
Miscellaneous two family · Owner of record: 1719 WATSON LLC · 2,400 sf lot · 1.19 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Floor 313p · 1 filing · 20 docs
Floor 212p · 1 filing · 20 docs
Floor 114p · 1 filing · 20 docs
Cellar16p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
EZ BUILDERS1804/09/2026
AB BUILDERS NY303/22/2026
1719 WATSON LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/12/2025$920K—Private party → 1719 WATSON LLC$322/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AG ENGINEERING PLLC112/03/2025
VASILIOS ARTEMIOU PE304/02/2025
NIKOLAI KATZ ARCHITECT111/12/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MABE GROUP INCGeneral Contractor404/09/2026
POWER DIRECT ELECTRIC INCElectrical103/22/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
A. M. PLUMBING COMPANYPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SHAHRISH SHUVO ENGINEERIN8524512/03/2025
Building Lifecycle
All (79)Filed (5)Permit Issued (5)Signed Off (5)Violation (9)Inspection (11)Objection (14)Special Inspection (30)
03/20/2026
Signed off — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01138987-I1
X01138987-I1
03/06/2026
Signed off — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01138987-I1
X01138987-S4
03/06/2026
Permit issued — Structural
X01138987-S4-ST
03/04/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/19/2026
Objection resolved — Addressed
02/11/2026
Signed off — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01138987-I1
X01138987-S3
02/11/2026
Signed off — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01138987-I1
X01138987-S2
12/16/2025
Objection resolved — Addressed
12/10/2025
Objection raised — Admin
12/10/2025
Objection raised — Admin
12/03/2025
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01138987-I1
X01138987-S4
11/21/2025
Special inspection requirement — Structural Cold-Formed Steel
Shahrish Shuvo
11/21/2025
Special inspection requirement — Structural Steel - Details
Shahrish Shuvo
11/21/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
11/21/2025
Special inspection requirement — Final
Shahrish Shuvo
11/05/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/24/2025
Signed off — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01138987-I1
X01138987-S1
10/24/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/23/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/15/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/08/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/04/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/28/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/10/2025
Violation issued (ECB, closed)
Construction
07/10/2025
Violation issued (ECB, closed)
Unknown
07/10/2025
Violation issued (ECB, closed)
Construction
07/09/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
07/09/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/09/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/16/2025
Permit issued — Sprinklers
X01138987-S3-EW-SP
05/27/2025
Permit issued — Mechanical Systems
X01138987-S1-MS
05/26/2025
Objection resolved — Addressed
05/22/2025
Permit issued — Plumbing
X01138987-S2-PL
05/21/2025
Permit issued — General Construction
X01138987-I1-GC
04/30/2025
Objection resolved — Addressed
04/21/2025
Objection resolved — Addressed
04/21/2025
Objection resolved — Addressed
04/10/2025
Objection raised — Structural
04/10/2025
Objection raised — Structural
04/10/2025
Objection raised — Fire_Protection
04/10/2025
Objection raised — Fire_Protection
04/09/2025
Objection resolved — Addressed
04/07/2025
Objection raised — Energy
04/03/2025
Violation issued (ECB, closed)
Construction
04/02/2025
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01138987-I1
X01138987-S3
04/01/2025
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01138987-I1
X01138987-S2
04/01/2025
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01138987-I1
X01138987-S1
04/01/2025
Special inspection requirement — Sprinkler Systems
Shahrish Shuvo
04/01/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
04/01/2025
Special inspection requirement — Post-installed Anchors
Shahrish Shuvo
03/27/2025
Special inspection requirement — Permanent certificate
Shahrish Shuvo
03/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
03/27/2025
Special inspection requirement — Post-installed Anchors
Shahrish Shuvo
03/27/2025
Special inspection requirement — Energy Code Compliance Inspections
Shahrish Shuvo
03/27/2025
Special inspection requirement — Ventilation and air distribution system
Shahrish Shuvo
03/27/2025
Special inspection requirement — Maintenance information
Shahrish Shuvo
03/27/2025
Special inspection requirement — HVAC-R and service water heating equipment
Shahrish Shuvo
03/27/2025
Special inspection requirement — HVAC-R and service water heating system controls
Shahrish Shuvo
03/27/2025
Special inspection requirement — Duct leakage testing, insulation and design
Shahrish Shuvo
03/27/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Shahrish Shuvo
Latest 60 of 79 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offAB BUILDERS NY03/06/2026
DOB NOWSprinklersSigned-offA M B MECHANICAL INC06/16/2025
DOB NOWMechanical SystemsSigned-offAB BUILDERS NY05/27/2025
DOB NOWPlumbingSigned-offA. M. PLUMBING COMPANY05/22/2025
DOB NOWGeneral ConstructionPermit IssuedAB BUILDERS NY05/21/2025
1 project · most recent 12/03/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
12/03/2025Signed-offAB BUILDERS NYHeating and Air Conditioning Systems
Heat / Cool
Daikin RO-SZ12-LA-J 21,600 BTU · Heat Pump Outdoor ×7
RO-SZ12-LA-J, RO-SZ12-AB-J 24,000 BTU · Heat Pump Outdoor ×2
1 project · most recent 12/03/2025
Sprinkler System
FiledStatusContractorScope
12/03/2025Signed-offPRIME PIPING & HEATING INSprinkler System
1 project · most recent 12/03/2025
Storm Water/Sanitary
FiledStatusContractorScope
12/03/2025Signed-offA. M. PLUMBING COMPANYStorm, Water/Sanitary
2 projects · most recent 07/17/2025
General Wiring
FiledStatusContractorScope
07/17/2025CompletePOWER DIRECT ELECTRIC INCGeneral Wiring
05/23/2025CompletePOWER DIRECT ELECTRIC INC—
1 project · most recent 12/03/2025
Steel
FiledStatusContractorScope
12/03/2025Signed-offAB BUILDERS NYSteel
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
03/04/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/05/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/24/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/23/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/15/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/08/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/04/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/28/2025Pass-Final CND-Occupancy InspectionPassView ↗
07/09/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
07/09/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/09/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
11/21/2025Structural Cold-Formed SteelShahrish Shuvospecial
11/21/2025Structural Steel - DetailsShahrish Shuvospecial
11/21/2025Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
11/21/2025FinalShahrish Shuvoprogress
04/01/2025Sprinkler SystemsShahrish Shuvospecial
04/01/2025Fire-Resistant Penetrations and JointsShahrish Shuvospecial
04/01/2025Post-installed AnchorsShahrish Shuvospecial
03/27/2025Permanent certificateShahrish Shuvoenergy_progress
03/27/2025Fire-Resistant Penetrations and JointsShahrish Shuvospecial
03/27/2025Post-installed AnchorsShahrish Shuvospecial
03/27/2025Energy Code Compliance InspectionsShahrish Shuvoprogress
03/27/2025Ventilation and air distribution systemShahrish Shuvoenergy_progress
03/27/2025Maintenance informationShahrish Shuvoenergy_progress
03/27/2025HVAC-R and service water heating equipmentShahrish Shuvoenergy_progress
03/27/2025HVAC-R and service water heating system controlsShahrish Shuvoenergy_progress
03/27/2025Duct leakage testing, insulation and designShahrish Shuvoenergy_progress
03/27/2025HVAC-R and service water piping design and insulationShahrish Shuvoenergy_progress
03/26/2025FinalShahrish Shuvoprogress
03/26/2025Mechanical SystemsShahrish Shuvospecial
02/04/2025Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
11/07/2024Energy Code Compliance InspectionsShahrish Shuvoprogress
11/07/2024Fire-Resistance Rated ConstructionShahrish Shuvoprogress
11/07/2024Insulation placement and R valuesShahrish Shuvoenergy_progress
11/07/2024Fenestration areasShahrish Shuvoenergy_progress
11/07/2024Interior lighting powerShahrish Shuvoenergy_progress
Latest 25 of 32.
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/19/2026X01138987-S3Request digital key ↗
08/19/2026X01138987-S2Request digital key ↗
08/19/2026X01138987-S1Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications14
▸DOB NOWProgress Inspector Seal & Signature5
09/01/2026X01138987-I1Open ↗
09/01/2026X01138987-I1Open ↗
08/26/2026X01138987-S4Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/19/2026X01138987-S3Open ↗
08/19/2026X01138987-S2Open ↗
08/19/2026X01138987-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026X01138987-I1Open ↗
08/26/2026X01138987-S4Open ↗
08/23/2026X01138987-S1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist1
08/13/2026X01138987-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X01138987-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026X01138987-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026X01138987-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/19/2026X01138987-S2Open ↗
08/19/2026X01138987-S1Open ↗
08/19/2026X01138987-I1Open ↗
Showing 3 of 5 on file for this type
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/19/2026X01138987-I1Open ↗