| Owner | Filings | Most Recent |
|---|---|---|
| OMOS LEGACY HOLDINGS | 25 | 07/08/2026 |
| HOME DEV INC PRECISION | 1 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| TABRIZ DESIGN GROUP | 10 | 02/07/2024 |
| TABRIZ GROUP ENTERPRISES | 4 | 11/30/2023 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| PRECISION HOME DEV INC | General Contractor | 11 | 07/08/2026 |
| GO PRO FIRE PROTECTION C | Fire Protection | 1 | 07/08/2026 |
| INFINITI ESC PLUMBING COR | Plumbing | 1 | 07/08/2026 |
| W.R. PLBG AND HTG CORP | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| TABRIZ GROUP ENTERPRISES | 3275 | 10 | 02/07/2024 |
| TRIANGLE INSPECTION & TES | 7495 | 4 | 02/07/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Curb Cut | Signed-off | PRECISION HOME DEV INC | 11/30/2023 |
| DOB NOW | Curb Cut | Signed-off | PRECISION HOME DEV INC | 11/22/2023 |
| DOB NOW | Sprinklers | Signed-off | GO PRO FIRE PROTECTION C | 08/14/2023 |
| DOB NOW | Plumbing | Signed-off | W.R. PLBG AND HTG CORP | 06/14/2023 |
| DOB NOW | General Construction | Permit Issued | PRECISION HOME DEV INC | 06/01/2023 |
| DOB NOW | Plumbing | Signed-off | INFINITI ESC PLUMBING COR | 02/09/2023 |
| DOB NOW | General Construction | Permit Issued | PRECISION HOME DEV INC | 12/06/2022 |
| DOB NOW | Construction Fence | Signed-off | PRECISION HOME DEV INC | 10/26/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 11/30/2023 | Permit Issued | PRECISION HOME DEV INC | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Cooper & Hunter COOPER AND HUNTER. MODEL # CH-18MES-230VO, 4,000 BTU · Condensing Unit ×2 Goodman GMEC96060 40,000 BTU · Condensing Unit ×2 Ventilation Panasonic FV-04VE1 40 CFM · Exhaust Fan ×6 Lifebreath 530ERV 1,170 CFM · Erv ×4 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/10/2023 | Complete | C & A ELECTRICAL CORP | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/30/2023 | Permit Issued | PRECISION HOME DEV INC | Steel |
| Date | Type | Result | Report |
|---|---|---|---|
| 01/19/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 12/07/2023 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 11/13/2023 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 11/07/2023 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 08/29/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 07/06/2023 | Pass-Final PL - Underground | Pass | View ↗ |
| 06/29/2023 | Pass-Final PL - Underground | Pass | View ↗ |
| 06/12/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 03/22/2023 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 03/22/2023 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 03/22/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 02/07/2024 | Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities | Rajasekhar Sakhamuri | special |
| 02/07/2024 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | BAKHTIAR SHAMLOO | special |
| 02/07/2024 | Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities | Rajasekhar Sakhamuri | special |
| 02/07/2024 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | BAKHTIAR SHAMLOO | special |
| 01/09/2024 | Structural Cold-Formed Steel | BAKHTIAR SHAMLOO | special |
| 01/09/2024 | Structural Steel - Details | BAKHTIAR SHAMLOO | special |
| 01/09/2024 | Footing and Foundation | BAKHTIAR SHAMLOO | progress |
| 01/09/2024 | Final | HARI SONI | progress |
| 01/09/2024 | Lighting controls | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Duct leakage testing, insulation and design | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Interior lighting power | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Maintenance information | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Shutoff dampers | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Fenestration air leakage | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Air barrier — testing | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Insulation placement and R values | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Exterior lighting power | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Metering | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Fenestration and door U-factor and product ratings | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | HVAC-R and service water heating equipment | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Air barrier continuity plan testing | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | HVAC-R and service water heating system controls | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Fenestration areas | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | HVAC-R and service water piping design and insulation | BAKHTIAR SHAMLOO | energy_progress |
| 01/09/2024 | Air barrier - visual inspection | BAKHTIAR SHAMLOO | energy_progress |