← Back
Two family frame
172 HARBOR ROAD
STATEN ISLAND · Mariner's Harbor-Arlington-Graniteville · BIN 5028091
💬 Discuss this project
1920Year Built
2Stories
B2Building Class
R3-2Zoning
1,968 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 5,450 sf lot · 0.36 FAR built · Flood zone X
Locations of Work
Electrical
Roof1p · 1 filing · 9 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PARKER AND WEST ENGINEERING, PLLC107/23/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNRUN103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNRUN INSTALLATION SVCGeneral Contractor203/21/2026
SUNRUN SOLAR ELECTL CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PARKER AND WEST ENGINEERI5272107/23/2024
Building Lifecycle
All (15)Filed (1)Permit Issued (1)Signed Off (1)Violation (7)Special Inspection (5)
07/09/2025
Signed off — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01082969-I1
07/30/2024
Permit issued — Solar
S01082969-I1-SL
07/23/2024
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01082969-I1
07/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walid Abdulla
07/18/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Walid Abdulla
07/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Walid Abdulla
07/18/2024
Special inspection requirement — Final
Walid Abdulla
07/18/2024
Special inspection requirement — Air barrier - visual inspection
Walid Abdulla
09/20/2023
Violation issued (HPD, closed)
A
09/20/2023
Violation issued (HPD, closed)
B
09/20/2023
Violation issued (HPD, closed)
C
09/15/2023
Violation issued (HPD, closed)
I
09/13/2023
Violation issued (HPD, closed)
C
09/13/2023
Violation issued (HPD, closed)
A
01/22/2009
Violation issued (ECB, closed)
Boilers
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNRUN INSTALLATION SVC07/30/2024
1 project · most recent 07/23/2024
FiledStatusContractorScope
07/23/2024CompleteSUNRUN SOLAR ELECTL CORP—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/18/2024Fire-Resistant Penetrations and JointsWalid Abdullaspecial
07/18/2024Structural Stability – Alterations of existing buildingsWalid Abdullaspecial
07/18/2024Energy Code Compliance InspectionsWalid Abdullaprogress
07/18/2024FinalWalid Abdullaprogress
07/18/2024Air barrier - visual inspectionWalid Abdullaenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026S01082969-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/28/2026S01082969-I1Open ↗
08/28/2026S01082969-I1Open ↗
08/28/2026S01082969-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026S01082969-I1Open ↗
08/28/2026S01082969-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026S01082969-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026S01082969-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026S01082969-I1Open ↗