← Back
Professional building / stand-alone funeral home
1725 CROSBY AVENUE
BRONX · BIN 2046100
💬 Discuss this project
1940Year Built
2Stories
O7Building Class
R7-1Zoning
8,000 sfGross Floor Area
1Units
0 Open Violations
Professional building / stand-alone funeral home · Owner of record: L TREE REALTY LLC · 6,900 sf lot · 1.16 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 19 docs
Floor 2Under Construction21p · 3 filings · 20 docs
Floor 1Under Construction19p · 3 filings · 20 docs
CellarUnder Construction22p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
L TREE REALTY1909/03/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/14/2024$2.8M—— → —$350/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AMERILAND BROOK LLC408/24/2026
BRIAN ILL DEVELOPMENT LLC210/06/2025
CNY ENGINEERING P.C106/19/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AMERILAND BROOK LLC403/21/2026
CNY ENGINEERING PC203/21/2026
BRIAN ILL DEVELOPMENT LLC103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KALE CONSTRUCTION INCGeneral Contractor409/03/2026
RRP PLUMBING CORPFire Protection107/08/2026
WATSON'S PLBG, HTG, & BDGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AMERILAND BROOK LLC1506508/24/2026
BRIAN ILL DEVELOPMENT LLC1402210/06/2025
Building Lifecycle
All (39)Filed (7)Permit Issued (6)Violation (15)Objection (11)
09/02/2026
Permit issued — Construction Fence
X01192929-S5-FN
08/24/2026
Filed — Alteration
FILE PL & SP WORKTYPE IN CONJUNCTION WITH JOB#X01192929 & X01154724
X01329866-P1
07/06/2026
Permit issued — Sprinklers
X01329866-I1-EW-SP
07/06/2026
Permit issued — Mechanical Systems
X01192929-S1-MS
06/17/2026
Permit issued — Plumbing
X01329866-I1-PL
04/16/2026
Objection resolved — Resolved
03/05/2026
Permit issued — General Construction
X01192929-I1-GC
02/08/2026
Filed — Alteration CO
INSTALL NEW HVAC SYSTEM FOR THE TWO STORY COMMERCIAL BUILDING SUBSEQUENT WITH DOB JOB#X01192929, NO CHANGE IN USE, EGRESS AND OCCUPANCY.
X01192929-P1
12/16/2025
Objection raised — Cost
12/16/2025
Objection raised — Admin
12/08/2025
Filed — Alteration
FILE PL & SP WORKTYPE IN CONJUNCTION WITH JOB#X01192929 & X01154724
X01329866-I1
10/06/2025
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL SPACE. NO CHANGE IN USE, OCCUPACY OR EGRESS.
X01154724-P1
08/14/2025
Objection raised — Cost
08/14/2025
Objection resolved — Addressed
07/07/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
07/02/2025
Objection raised — Cost
07/02/2025
Objection raised — Energy
07/02/2025
Objection raised — Admin
06/19/2025
Filed — Alteration CO
INSTALL NEW HVAC SYSTEM FOR THE TWO STORY COMMERCIAL BUILDING SUBSEQUENT WITH DOB JOB#X01192929, NO CHANGE IN USE, EGRESS AND OCCUPANCY.
X01192929-S1
03/11/2025
Filed — Alteration CO
INSTALL NEW HVAC SYSTEM FOR THE TWO STORY COMMERCIAL BUILDING SUBSEQUENT WITH DOB JOB#X01192929, NO CHANGE IN USE, EGRESS AND OCCUPANCY.
X01192929-I1
02/13/2025
Permit issued — General Construction
X01154724-I1-GC
01/31/2025
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL SPACE. NO CHANGE IN USE, OCCUPACY OR EGRESS.
X01154724-I1
10/01/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/03/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/01/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/07/1991
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedKALE CONSTRUCTION INC09/02/2026
DOB NOWSprinklersPermit IssuedRRP PLUMBING CORP07/06/2026
DOB NOWMechanical SystemsPermit IssuedKALE CONSTRUCTION INC07/06/2026
DOB NOWPlumbingPermit IssuedWATSON'S PLBG, HTG, & BDG06/17/2026
DOB NOWGeneral ConstructionPermit IssuedKALE CONSTRUCTION INC03/05/2026
DOB NOWGeneral ConstructionPermit IssuedKALE CONSTRUCTION INC02/13/2025
1 project · most recent 02/08/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
02/08/2026Permit IssuedKALE CONSTRUCTION INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PUHY-P96TNU-A 96,000 BTU · Vrf Outdoor ×2
PUHY-P120TNU-A 120,000 BTU · Vrf Outdoor ×1
PUMY-HP48NKMU1 48,000 BTU · Vrf Outdoor ×1
Ventilation
Broan AE50110DC 50 CFM · Exhaust Fan ×4
Mitsubishi Electric LGH-F300RX5-E1 300 CFM · Erv ×2
LGH-F600RX5-E1 600 CFM · Erv ×1
LGH-F940RVX2-E 940 CFM · Erv ×1
Dayton 56JN96 11,237 CFM · Exhaust Fan ×1
1 project · most recent 08/24/2026
FiledStatusContractorScope
08/24/2026Permit IssuedRRP PLUMBING CORP93 heads
1 project · most recent 08/24/2026
Gas Water/Sanitary
FiledStatusContractorScope
08/24/2026Permit IssuedWATSON'S PLBG, HTG, & BDGGas, Water/Sanitary
3 projects · most recent 09/25/2026
General Wiring
FiledStatusContractorScope
09/25/2026Permit IssuedKWONG MING ELECTRIC INC—
07/01/2026Permit IssuedKJK ELECTRIC INCGeneral Wiring
12/01/2021CompleteAMC ELEC'L SERVICES, INC.General Wiring
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
08/24/2026Sprinkler SystemsXIAOHONG ZHAOspecial
01/19/2026Lighting controlsXIAOHONG ZHAOenergy_progress
01/19/2026Interior lighting powerXIAOHONG ZHAOenergy_progress
01/19/2026Fenestration and door U-factor and product ratingsXIAOHONG ZHAOenergy_progress
01/19/2026MasonryXIAOHONG ZHAOspecial
01/19/2026Fire-Resistant Penetrations and JointsXIAOHONG ZHAOspecial
01/19/2026Energy Code Compliance InspectionsXIAOHONG ZHAOprogress
01/19/2026Fenestration areasXIAOHONG ZHAOenergy_progress
01/19/2026Air barrier - visual inspectionXIAOHONG ZHAOenergy_progress
01/19/2026Fenestration air leakageXIAOHONG ZHAOenergy_progress
12/05/2025Sprinkler SystemsXIAOHONG ZHAOspecial
10/07/2025Fire-Resistant Penetrations and JointsBRIAN ILLspecial
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/19/2026X01192929-S1Request digital key ↗
08/19/2026X01192929-I1Request digital key ↗
08/19/2026X01192929-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/13/2026X01192929-I1Open ↗
08/13/2026X01192929-P1Open ↗
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/19/2026X01192929-I1Open ↗
08/19/2026X01192929-P1Open ↗
08/19/2026X01192929-S1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/23/2026X01329866-P1Open ↗
09/01/2026X01192929-P1Open ↗
08/24/2026X01154724-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026X01192929-P1Open ↗
09/01/2026X01192929-P1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/13/2026X01192929-P1Open ↗
08/13/2026X01192929-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/19/2026X01192929-I1Open ↗
08/19/2026X01192929-P1Open ↗
08/19/2026X01192929-S1Open ↗
Showing 3 of 5 on file for this type
▸Other Documents2
▸DOB NOWProperty Ownership Certification2
08/19/2026X01192929-I1Open ↗
08/19/2026X01192929-P1Open ↗