← Back
Two stories - detached, small or mid-size
173-60 105 AVENUE
QUEENS · South Jamaica · BIN 4218116
💬 Discuss this project
1925Year Built
2Stories
A1Building Class
R4-1Zoning
974 sfGross Floor Area
1Units
3 Open Violations 2 unresolved · 1 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · 2,000 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
ArchitectureGeneralOther
Filed — no permit issued3p · 1 filing · 3 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RR ENGINEERING PLLC103/23/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NOEL BUILDING CONSULTING INC203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TRIANGLE INSPECTION & TES7495103/23/2025
Building Lifecycle
All (13)Filed (1)Violation (3)Objection (6)Special Inspection (3)
06/22/2025
Objection resolved — Addressed
06/09/2025
Objection resolved — Addressed
06/09/2025
Objection resolved — Addressed
06/08/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
04/07/2025
Objection raised — Other
04/07/2025
Objection raised — Other
04/07/2025
Objection raised — Structural
03/23/2025
Filed — Alteration
Q01179225-I1
03/23/2025
Special inspection requirement — Fire-Resistance Rated Construction
02/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Rajasekhar Sakhamuri
08/06/2024
Violation issued (ECB, open)
Construction
08/06/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/06/2024
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDSUNRUN INSTALLATION SVC11/21/2023
1 project · most recent 11/21/2023
FiledStatusContractorScope
11/21/2023CompleteSUNRUN SOLAR ELECTL CORP—
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
06/08/2025Structural Stability – Alterations of existing buildings—special
03/23/2025Fire-Resistance Rated Construction—progress
02/10/2025Fire-Resistant Penetrations and JointsRajasekhar Sakhamurispecial
▾Documents — 27 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026Q01179225-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
11/03/2023440811926Open ↗
▸BISWORK PERMIT APPLICATION1
11/21/2023440811926Open ↗
▸Seals & Professional Certifications4
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
11/03/2023440811926Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
11/03/2023440811926Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/03/2023440811926Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/20/2026Q01179225-I1Open ↗
▸Safety & Tenant Protection1
▸BISTPP1: TENANT PROTECTION PLAN1
11/06/2023440811926Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/03/2023440811926Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/20/2026Q01179225-I1Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
02/14/2024440811926Open ↗
11/03/2023440811926Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
02/14/2024440811926Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
02/23/2024440811926Open ↗
▸BISNYCECC ANALYSIS1
11/03/2023440811926Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
11/03/2023440811926Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
11/03/2023440811926Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
02/14/2024440811926Open ↗
11/03/2023440811926Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION3
02/23/2024440811926Open ↗
02/23/2024440811926Open ↗
11/03/2023440811926Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
02/23/2024440811926Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
02/14/2024440811926Open ↗
11/03/2023440811926Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
02/23/2024440811926Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
11/03/2023440811926Open ↗