| Firm | Filings | Most Recent |
|---|---|---|
| WEXLER ASSOCIATES | 2 | 03/30/2026 |
| FLORINELA MURESAN | 3 | 03/28/2026 |
| MARTIN H. KAPELL | 1 | 03/27/2026 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 03/30/2026 | — | — | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Ephoca AIO WALL MOUNTED W/ ERV ENERGY STAR 9,000 BTU · Heat Pump Outdoor ×76 Captiveaire CAS-HVAC3-E.902-24-20T-ERV 185,400 BTU ×1 Ventilation Greenheck AX-72-43-0415 2,930 CFM · Exhaust Fan ×1 CUE-060-G 230 CFM · Exhaust Fan ×1 G-100HP-VG 910 CFM · Exhaust Fan ×1 USF-04-B6 1,200 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/30/2026 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/30/2026 | — | — | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/30/2026 | — | — | Concrete, Masonry |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 03/30/2026 | Concrete - Cast-In-Place | — | special |
| 03/30/2026 | Subsurface Investigations (Borings/Test Pits) | — | special |
| 03/30/2026 | Deep Foundation Elements | — | special |
| 03/30/2026 | Subsurface Conditions – Fill Placement & In-Place Density | — | special |
| 03/30/2026 | Subgrade Inspections | — | special |
| 03/30/2026 | Concrete - Cast-In-Place | — | special |
| 03/30/2026 | Masonry | — | special |
| 03/30/2026 | Post-installed Anchors | — | special |
| 03/21/2026 | Insulation placement and R values | — | energy_progress |
| 03/21/2026 | Exterior Insulation and Finish Systems (EIFS) | — | special |
| 03/21/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 03/21/2026 | Wall Panels, Curtain Walls, and Veneers | — | special |
| 03/21/2026 | Energy Code Compliance Inspections | — | progress |
| 03/21/2026 | Fire-Resistance Rated Construction | — | progress |
| 03/21/2026 | Air barrier - visual inspection | — | energy_progress |
| 03/21/2026 | Air barrier continuity plan testing | — | energy_progress |
| 03/21/2026 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 03/21/2026 | Fenestration areas | — | energy_progress |
| 03/21/2026 | Fenestration air leakage | — | energy_progress |
| 03/21/2026 | Protection of exposed foundation insulation | — | energy_progress |
| 03/20/2026 | Footing and Foundation | — | progress |
| 03/20/2026 | Final | — | progress |
| 03/20/2026 | Final | — | progress |
| 03/13/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 03/13/2026 | HVAC-R and service water heating system controls | — | energy_progress |