← Back
Three families
1733 WEST 5 STREET
BROOKLYN · Gravesend (West) · BIN 3176940
💬 Discuss this project
1920Year Built
2Stories
C0Building Class
R7AZoning
2,720 sfGross Floor Area
3Units
Rent Stabilized10 Open Violations ▸FDNY Report ↗
Three families · 2,617 sf lot · 1.04 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/17/2022$1.6M—— → —$588/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHANDA ENGINEERING CONSULTANT PC208/10/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HALF SQUARE403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MM CONTRACTING NY INCGeneral Contractor303/21/2026
TOP DOG PLBG & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CHANDA ENG. CONSULTANT PC6842208/10/2022
Building Lifecycle
All (28)Filed (2)Permit Issued (2)Violation (13)Inspection (7)Special Inspection (4)
05/06/2026
Violation issued (HPD, open)
A
11/20/2025
Violation issued (HPD, open)
I
06/11/2025
Violation issued (HPD, open)
A
11/27/2024
Violation issued (HPD, open)
I
04/12/2024
Violation issued (HPD, open)
A
11/21/2023
Violation issued (HPD, open)
I
07/17/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
07/07/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
05/30/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/27/2023
Violation issued (HPD, open)
A
02/22/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/07/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/10/2022
Violation issued (HPD, open)
I
10/21/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/21/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/16/2022
Permit issued — Plumbing
B00784488-S1-PL
08/11/2022
Permit issued — General Construction
B00784488-I1-GC
08/10/2022
Filed — Alteration
Install 3 new Navien residential comb0-boilers as per plan.
B00784488-S1
08/04/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
KARTIK CHANDA
08/04/2022
Special inspection requirement — Energy Code Compliance Inspections
KARTIK CHANDA
08/02/2022
Filed — Alteration
Install 3 new Navien residential comb0-boilers as per plan.
B00784488-I1
08/01/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
KARTIK CHANDA
08/01/2022
Special inspection requirement — Fire-Resistance Rated Construction
KARTIK CHANDA
03/02/2022
Violation issued (HPD, open)
A
04/13/2021
Violation issued (HPD, open)
A
04/13/2021
Violation issued (HPD, closed)
I
10/22/2018
Violation issued (HPD, closed)
I
02/25/2015
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offTOP DOG PLBG & HTG CORP08/16/2022
DOB NOWGeneral ConstructionSigned-offMM CONTRACTING NY INC08/11/2022
1 project · most recent 08/10/2022
Water/Sanitary
FiledStatusContractorScope
08/10/2022Signed-offTOP DOG PLBG & HTG CORPWater/Sanitary
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
07/17/2023Pass-Final General Construction Non-Directive 14PassView ↗
07/07/2023Fail-Final General Construction Non-Directive 14FailView ↗
05/30/2023Fail-Final General Construction Non-Directive 14FailView ↗
02/22/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/07/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/21/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/21/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
08/04/2022Fire-Resistant Penetrations and JointsKARTIK CHANDAspecial
08/04/2022Energy Code Compliance InspectionsKARTIK CHANDAprogress
08/01/2022Fire-Resistant Penetrations and JointsKARTIK CHANDAspecial
08/01/2022Fire-Resistance Rated ConstructionKARTIK CHANDAprogress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/28/2026B00784488-I1Request digital key ↗
08/28/2026B00784488-S1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/28/2026B00784488-I1Open ↗
08/28/2026B00784488-S1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/29/2026B00784488-S1Open ↗
08/25/2026B00784488-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/29/2026B00784488-S1Open ↗
08/25/2026B00784488-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/28/2026B00784488-I1Open ↗
08/28/2026B00784488-S1Open ↗
08/28/2026B00784488-S2Open ↗