← Back
Two stories - detached, small or mid-size
1740 ARDEN AVENUE
STATEN ISLAND · BIN 5070184
💬 Discuss this project
1925Year Built
2Stories
A1Building Class
R3XZoning
2,075 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · Owner of record: EAGLE DEVELOPMENT 23 LLC · 4,250 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Floor 214p · 1 filing · 20 docs
Floor 110p · 1 filing · 20 docs
Cellar8p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
EAGLE DEVELOPMENT 231907/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RYAN DESIGN ARCHITECTURE608/28/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
OMEGA STUCCO CORPGeneral Contractor407/08/2026
ALL PRO PLBG & HTG INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RYAN DESIGN ARCHITECTURE7159408/28/2025
Building Lifecycle
All (50)Filed (6)Permit Issued (4)Inspection (6)Objection (10)Special Inspection (24)
09/02/2025
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
08/28/2025
Filed — Alteration
plumbing
S00979787-P2
08/26/2025
Permit issued — Plumbing
S00979787-S2-PL
03/01/2025
Filed — Alteration
plumbing
S00979787-P1
01/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Daniel Ryan
01/15/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Daniel Ryan
01/15/2025
Special inspection requirement — HVAC-R and service water heating system controls
Daniel Ryan
01/15/2025
Special inspection requirement — HVAC-R and service water heating equipment
Daniel Ryan
01/15/2025
Special inspection requirement — Maintenance information
Daniel Ryan
01/15/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Daniel Ryan
01/13/2025
Special inspection requirement — Air barrier - visual inspection
Daniel Ryan
01/13/2025
Special inspection requirement — Insulation placement and R values
Daniel Ryan
01/13/2025
Special inspection requirement — Electric vehicle service equipment requirements
Daniel Ryan
01/13/2025
Special inspection requirement — Protection of exposed foundation insulation
Daniel Ryan
01/13/2025
Special inspection requirement — Concrete - Cast-In-Place
Daniel Ryan
01/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Daniel Ryan
01/13/2025
Special inspection requirement — Fenestration air leakage
Daniel Ryan
01/13/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
anthony santoro
01/13/2025
Special inspection requirement — Energy Code Compliance Inspections
Daniel Ryan
01/13/2025
Special inspection requirement — Final
JIAN DENG
01/13/2025
Special inspection requirement — Fire-Resistance Rated Construction
Daniel Ryan
01/13/2025
Special inspection requirement — Footing and Foundation
Daniel Ryan
01/13/2025
Special inspection requirement — Subgrade Inspections
Daniel Ryan
01/13/2025
Special inspection requirement — Metering
Daniel Ryan
01/13/2025
Special inspection requirement — Interior lighting power
Daniel Ryan
01/13/2025
Special inspection requirement — Fenestration areas
Daniel Ryan
01/13/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Daniel Ryan
01/13/2025
Special inspection requirement — Maintenance information
Daniel Ryan
07/25/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/24/2024
Filed — Alteration
plumbing
S00979787-S3
06/06/2024
Permit issued — Plumbing
S00979787-S2-PL
05/03/2024
Objection resolved — Addressed
04/16/2024
Objection raised — Other
04/09/2024
Filed — Alteration
plumbing
S00979787-S2
04/02/2024
Permit issued — Foundation
S00979787-I1-GC-CX
03/14/2024
Permit issued — Construction Fence
S00979787-S1-FN
03/07/2024
Objection resolved — Addressed
02/28/2024
Objection resolved — Addressed
02/27/2024
Objection raised — Inspections
02/27/2024
Objection raised — Inspections
02/22/2024
Filed — Alteration
plumbing
S00979787-S1
02/22/2024
Objection resolved — Addressed
02/21/2024
Objection raised — Other
02/13/2024
Objection resolved — Addressed
01/12/2024
Objection raised — Other
12/22/2023
Filed — Alteration
plumbing
S00979787-I1
12/15/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/07/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/17/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/19/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedALL PRO PLBG & HTG INC08/26/2025
DOB NOWPlumbingPermit IssuedALL PRO PLBG & HTG INC06/06/2024
DOB NOWFoundationPermit IssuedOMEGA STUCCO CORP04/02/2024
DOB NOWConstruction FencePermit IssuedOMEGA STUCCO CORP03/14/2024
1 project · most recent 08/28/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/28/2025Permit IssuedALL PRO PLBG & HTG INCGas, Storm, Water/Sanitary
1 project · most recent 08/07/2024
General Wiring
FiledStatusContractorScope
08/07/2024CompleteE D ELECTRICAL INCGeneral Wiring
1 project · most recent 08/28/2025
FiledStatusContractorScope
08/28/2025Permit IssuedALL PRO PLBG & HTG INC1 scope_items
1 project · most recent 08/28/2025
Fence
FiledStatusContractorScope
08/28/2025Permit IssuedALL PRO PLBG & HTG INCFence
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
09/02/2025Pass-Final PL - Up to 9 Requested FloorsPassView ↗
07/25/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/15/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/07/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/17/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/19/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
01/15/2025Fire-Resistant Penetrations and JointsDaniel Ryanspecial
01/15/2025Subsurface Investigations (Borings/Test Pits)Daniel Ryanspecial
01/15/2025HVAC-R and service water heating system controlsDaniel Ryanenergy_progress
01/15/2025HVAC-R and service water heating equipmentDaniel Ryanenergy_progress
01/15/2025Maintenance informationDaniel Ryanenergy_progress
01/15/2025HVAC-R and service water piping design and insulationDaniel Ryanenergy_progress
01/13/2025Air barrier - visual inspectionDaniel Ryanenergy_progress
01/13/2025Insulation placement and R valuesDaniel Ryanenergy_progress
01/13/2025Electric vehicle service equipment requirementsDaniel Ryanenergy_progress
01/13/2025Protection of exposed foundation insulationDaniel Ryanenergy_progress
01/13/2025Concrete - Cast-In-PlaceDaniel Ryanspecial
01/13/2025Fire-Resistant Penetrations and JointsDaniel Ryanspecial
01/13/2025Fenestration air leakageDaniel Ryanenergy_progress
01/13/2025Subsurface Investigations (Borings/Test Pits)anthony santorospecial
01/13/2025Energy Code Compliance InspectionsDaniel Ryanprogress
01/13/2025FinalJIAN DENGprogress
01/13/2025Fire-Resistance Rated ConstructionDaniel Ryanprogress
01/13/2025Footing and FoundationDaniel Ryanprogress
01/13/2025Subgrade InspectionsDaniel Ryanspecial
01/13/2025MeteringDaniel Ryanenergy_progress
01/13/2025Interior lighting powerDaniel Ryanenergy_progress
01/13/2025Fenestration areasDaniel Ryanenergy_progress
01/13/2025Fenestration and door U-factor and product ratingsDaniel Ryanenergy_progress
01/13/2025Maintenance informationDaniel Ryanenergy_progress
▾Documents — 54 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/21/2026S00979787-P1Request digital key ↗
08/21/2026S00979787-P2Request digital key ↗
08/21/2026S00979787-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026S00979787-P1Open ↗
08/13/2026S00979787-I1Open ↗
▸Seals & Professional Certifications30
▸DOB NOWProgress Inspector Seal & Signature18
09/23/2026S00979787-P1Open ↗
09/23/2026S00979787-P1Open ↗
09/23/2026S00979787-P1Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/13/2026S00979787-S3Open ↗
08/13/2026S00979787-S2Open ↗
08/13/2026S00979787-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/23/2026S00979787-P1Open ↗
09/23/2026S00979787-P1Open ↗
09/23/2026S00979787-P1Open ↗
Showing 3 of 6 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026S00979787-P1Open ↗
08/13/2026S00979787-I1Open ↗
08/13/2026S00979787-S2Open ↗
Showing 3 of 4 on file for this type
▸Inspections & Test Reports6
▸DOB NOWSOIL REPORT4
08/13/2026S00979787-P1Open ↗
08/13/2026S00979787-S2Open ↗
08/13/2026S00979787-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026S00979787-S2Open ↗
08/13/2026S00979787-I1Open ↗
▸Other Documents6
▸DOB NOWSite Survey: Initial2
08/13/2026S00979787-I1Open ↗
08/13/2026S00979787-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026S00979787-I1Open ↗
08/13/2026S00979787-P1Open ↗
▸DOB NOWPlot Diagram2
08/13/2026S00979787-I1Open ↗
08/13/2026S00979787-P1Open ↗