← Back
Three families
1740 VAN BUREN STREET
BRONX · Pelham Parkway-Van Nest · BIN 2114349
💬 Discuss this project
2004Year Built
3Stories
C0Building Class
R5Zoning
3,370 sfGross Floor Area
3Units
Rent Stabilized1 Open Violation ▸
Three families · 2,900 sf lot · 1.16 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalGeneral
Roof1p · 1 filing · 3 docs
Filed — no permit issued10p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
UNLIMITED DEVELOPMENT CON103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
COBBLE COURT ENGINEERING103/14/2024
MOMENTUM SOLAR101/11/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
QUEST HOME IMPROVEMENT103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EMPIRE SOLAR SOLUTIONS.LLGeneral Contractor303/21/2026
LUNA NYC ELECTRIC CORPElectrical103/22/2026
MANUEL MEROElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
COBBLE COURT ENGINEERING7825103/14/2024
Building Lifecycle
All (28)Filed (2)Permit Issued (1)Signed Off (1)Violation (18)Objection (1)Special Inspection (5)
05/08/2026
Violation issued (HPD, open)
A
02/04/2026
Signed off — Alteration
X01018625-I1
06/13/2025
Violation issued (HPD, closed)
A
11/25/2024
Violation issued (HPD, closed)
I
04/16/2024
Violation issued (HPD, closed)
A
03/15/2024
Permit issued — Solar
X01018625-I1-SL
03/14/2024
Filed — Alteration
X01018625-I1
01/19/2024
Objection raised — Other
01/11/2024
Filed — Alteration
Installation of solar panels; Rooftop, Railed, Grid tied, 19 Panels, 7.6 KW
X00985057-I1
01/03/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/03/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
01/03/2024
Special inspection requirement — Energy Code Compliance Inspections
01/03/2024
Special inspection requirement — Final
01/03/2024
Special inspection requirement — Air barrier - visual inspection
11/16/2023
Violation issued (HPD, closed)
I
03/30/2023
Violation issued (HPD, closed)
A
11/03/2022
Violation issued (HPD, closed)
I
03/09/2022
Violation issued (HPD, closed)
I
03/09/2022
Violation issued (HPD, closed)
A
04/19/2021
Violation issued (HPD, closed)
I
04/19/2021
Violation issued (HPD, closed)
A
10/25/2018
Violation issued (HPD, closed)
I
12/07/2017
Violation issued (HPD, closed)
I
11/25/2016
Violation issued (HPD, closed)
I
10/19/2015
Violation issued (HPD, closed)
I
03/03/2015
Violation issued (HPD, closed)
I
05/12/2005
Violation issued (ECB, closed)
Construction
05/12/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offEMPIRE SOLAR SOLUTIONS.LL03/15/2024
BISPLISSUEDTHE PLUMBING COMPANY INC10/25/2007
BISOTISSUEDPAK BARKA GROUP INC06/01/2007
BISEQISSUEDDEMO-TECH CORP.06/02/1994
BIS—ISSUEDDEMO-TECH CORP06/02/1994
2 projects · most recent 03/14/2024
FiledStatusContractorScope
03/14/2024CompleteLUNA NYC ELECTRIC CORP—
01/11/2024Permit IssuedISLAND ELECTRIC CORP—
1 project · most recent 01/11/2024
FiledStatusContractorScope
01/11/2024——19 panels, 7.6 kw, 405 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
01/03/2024Fire-Resistant Penetrations and Joints—special
01/03/2024Structural Stability – Alterations of existing buildings—special
01/03/2024Energy Code Compliance Inspections—progress
01/03/2024Final—progress
01/03/2024Air barrier - visual inspection—energy_progress
▾Documents — 5 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026X01018625-I1Request digital key ↗
08/14/2026X00985057-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026X00985057-I1Open ↗
08/21/2026X01018625-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01018625-I1Open ↗