← Back
Miscellaneous one family
1749 ALBANY AVENUE
BROOKLYN · Flatlands · BIN 3214005
💬 Discuss this project
1930Year Built
2Stories
A9Building Class
R4Zoning
1,728 sfGross Floor Area
1Units
Rent Stabilized5 Open Violations 4 unresolved · 1 paperwork only ▸FDNY Report ↗
Miscellaneous one family · 2,000 sf lot · 0.86 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Roof2p · 1 filing · 6 docs
Floor 25p · 1 filing · 3 docs
Floor 15p · 1 filing · 3 docs
Cellar7p · 2 filings · 9 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STEVEN MCEVOY103/29/2022
IMC ARCHITECTURE DPC211/15/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CORE CONSULTANTS NYC303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALFONSO GIGANTEElectrical103/21/2026
GREGG NY PLUMBING, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SRA PLANNING & EXPEDITING5677211/15/2021
Building Lifecycle
All (43)Filed (3)Permit Issued (1)Violation (7)Inspection (4)Objection (20)Special Inspection (8)
11/24/2025
Violation issued (HPD, closed)
I
11/30/2023
Violation issued (HPD, closed)
I
03/01/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/14/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/29/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/07/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/07/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/29/2022
Filed — Alteration
B00657618-I1
03/28/2022
Permit issued — Plumbing
B00622621-I1-PL
01/14/2022
Objection raised — Fire_Protection
01/14/2022
Objection resolved — Addressed
11/15/2021
Filed — Alteration
B00622621-I1
11/15/2021
Objection raised — Admin
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Structural
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Alteration job cannot substitu
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Zoning
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Structural
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Zoning
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Zoning
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Site survey detailing building
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Structural
11/15/2021
Objection resolved — Addressed
11/09/2021
Filed — Alteration
APPLICATION IS FILED FOR THE REHABILITATION OF THE SINGLE-FAMILY RESIDENCE DUE TO FIRE DAMAGE. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00622616-I1
11/02/2021
Special inspection requirement — Interior lighting power
WILLIAM MONTAGUE
11/02/2021
Special inspection requirement — Energy Code Compliance Inspections
WILLIAM MONTAGUE
11/02/2021
Special inspection requirement — Fire-Resistance Rated Construction
WILLIAM MONTAGUE
11/02/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM MONTAGUE
11/02/2021
Special inspection requirement — Permanent certificate
WILLIAM MONTAGUE
11/02/2021
Special inspection requirement — Insulation placement and R values
WILLIAM MONTAGUE
11/02/2021
Special inspection requirement — Protection of exposed foundation insulation
WILLIAM MONTAGUE
11/01/2021
Special inspection requirement — Final
WILLIAM MONTAGUE
07/07/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/07/2021
Violation issued (ECB, open)
Zoning
05/11/2020
Violation issued (ECB, open)
Zoning
11/17/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedGREGG NY PLUMBING, INC03/28/2022
1 project · most recent 04/08/2022
General Wiring
FiledStatusContractorScope
04/08/2022Permit IssuedKINGS ELECTRIC CO., INC.General Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
03/01/2023Pass-Final CND-Occupancy InspectionPassView ↗
07/29/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/07/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/07/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
11/02/2021Interior lighting powerWILLIAM MONTAGUEenergy_progress
11/02/2021Energy Code Compliance InspectionsWILLIAM MONTAGUEprogress
11/02/2021Fire-Resistance Rated ConstructionWILLIAM MONTAGUEprogress
11/02/2021Fire-Resistant Penetrations and JointsWILLIAM MONTAGUEspecial
11/02/2021Permanent certificateWILLIAM MONTAGUEenergy_progress
11/02/2021Insulation placement and R valuesWILLIAM MONTAGUEenergy_progress
11/02/2021Protection of exposed foundation insulationWILLIAM MONTAGUEenergy_progress
11/01/2021FinalWILLIAM MONTAGUEprogress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/31/2026B00622621-I1Request digital key ↗
08/30/2026B00657618-I1Request digital key ↗
08/15/2026B00622616-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
01/24/2017340358981Open ↗
03/04/2016340358981Open ↗
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/31/2026B00622621-I1Open ↗
08/30/2026B00657618-I1Open ↗
08/13/2026B00622616-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B00622616-I1Open ↗
09/01/2026B00622616-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
03/04/2016340358981Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/04/2016340358981Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
03/04/2016340358981Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026B00622616-I1Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
03/04/2016340358981Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/31/2026B00622621-I1Open ↗
08/30/2026B00657618-I1Open ↗
08/13/2026B00622616-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
03/04/2016340358981Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
03/04/2016340358981Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
03/04/2016340358981Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
03/04/2016340358981Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
03/04/2016340358981Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
03/04/2016340358981Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
03/04/2016340358981Open ↗