← Back
Primarily 2 family with 1 store or office
175 SMITH STREET
BROOKLYN · BIN 3006104
💬 Discuss this project
1931Year Built
3Stories
S2Building Class
R6AZoning
3,500 sfGross Floor Area
3Units
1 Open Violation ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: 175 SMITH PROPERTY LLC · 1,500 sf lot · 2.33 FAR built · Flood zone X
Locations of Work
Mechanical
Floor 11p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SHAH BUILDERS203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/12/2021$2.1M—R&T MCDONALD LLC → 175 SMITH PROPERTY LLC$600/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PJM ARCHITECT, PC110/14/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A & W CERTIFIED COOL SYSTGeneral Contractor203/21/2026
IRVING BAPTISTEElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PJM ARCHITECT PC1450110/14/2022
Building Lifecycle
All (11)Filed (1)Permit Issued (1)Signed Off (1)Violation (5)Special Inspection (3)
09/14/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/21/2022
Signed off — Alteration
Application filed to propose the installation of two (2) 3-Ton (36,000 BTU) Daikin Electric Mini-Split System on roof and two (2) wall mounted inverters at first floor. No change in bulk, use or egress.
B08015297-I1
11/01/2022
Permit issued — Mechanical Systems
B08015297-I1-MS
10/14/2022
Filed — Alteration
Application filed to propose the installation of two (2) 3-Ton (36,000 BTU) Daikin Electric Mini-Split System on roof and two (2) wall mounted inverters at first floor. No change in bulk, use or egress.
B08015297-I1
10/04/2022
Special inspection requirement — Mechanical Systems
Peter Mugavero
10/04/2022
Special inspection requirement — Final
Peter Mugavero
10/04/2022
Special inspection requirement — Energy Code Compliance Inspections
Peter Mugavero
06/26/2001
Violation issued (ECB, closed)
HPD
06/15/2001
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/20/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offA & W CERTIFIED COOL SYST11/01/2022
BISEQISSUEDSHAH BUILDERS INC07/14/2014
BISOTISSUEDN/A03/21/2002
BISOTISSUEDTHE GFC IMPR04/07/2000
BISOTISSUEDTHE GFC IMPR02/18/2000
1 project · most recent 02/13/2023
General Wiring
FiledStatusContractorScope
02/13/2023Permit IssuedDELTA GREEN ELECTRIC INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
10/04/2022Mechanical SystemsPeter Mugaverospecial
10/04/2022FinalPeter Mugaveroprogress
10/04/2022Energy Code Compliance InspectionsPeter Mugaveroprogress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/28/2026B08015297-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
07/10/2014340163931Open ↗
▸BISWORK PERMIT APPLICATION1
07/10/2014340163931Open ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026B08015297-I1Open ↗
08/23/2026B08015297-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
07/10/2014340163931Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/10/2014340163931Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/10/2014340163931Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/28/2026B08015297-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026B08015297-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/28/2026B08015297-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/10/2014340163931Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
03/09/2021340163931Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
07/10/2014340163931Open ↗