← Back
Two family converted from one family
1753 74 STREET
BROOKLYN · BIN 3159085
💬 Discuss this project
1910Year Built
2Stories
B3Building Class
R5Zoning
1,432 sfGross Floor Area
2Units
Two family converted from one family · 1,767 sf lot · 0.81 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction1 filing · 16 docs
Floor 1Under Construction1 filing · 16 docs
CellarUnder Construction1 filing · 16 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
WEI STUDIO206/08/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NY BUILDING ASSOCIATES INGeneral Contractor107/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WEI STUDIO7998206/08/2026
Building Lifecycle
All (16)Filed (2)Permit Issued (2)Inspection (2)Special Inspection (10)
08/07/2026
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
07/15/2026
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
06/10/2026
Permit issued — General Construction
B01409624-I1-GC
06/09/2026
Permit issued — Plumbing
B01409624-S1-PL
06/08/2026
Filed — Alteration
GENERAL RENOVATION OF 2-FAMILY HOUSE WITH RELOCATED/NEW PLUMBING FIXTURES AND BOILER AND H.W.H. AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01409624-S1
06/08/2026
Filed — Alteration
GENERAL RENOVATION OF 2-FAMILY HOUSE WITH RELOCATED/NEW PLUMBING FIXTURES AND BOILER AND H.W.H. AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01409624-I1
05/30/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ruoyu Wei
05/30/2026
Special inspection requirement — Energy Code Compliance Inspections
Ruoyu Wei
05/30/2026
Special inspection requirement — HVAC-R and service water heating equipment
Ruoyu Wei
05/30/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Ruoyu Wei
05/30/2026
Special inspection requirement — HVAC-R and service water heating system controls
Ruoyu Wei
05/30/2026
Special inspection requirement — Maintenance information
Ruoyu Wei
05/30/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ruoyu Wei
05/30/2026
Special inspection requirement — Final
Ruoyu Wei
05/30/2026
Special inspection requirement — Energy Code Compliance Inspections
Ruoyu Wei
05/30/2026
Special inspection requirement — Fire-Resistance Rated Construction
Ruoyu Wei
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedNY BUILDING ASSOCIATES IN06/10/2026
DOB NOWPlumbingPermit IssuedAMERICAN STANDARD P&H CORORP.06/09/2026
1 job · most recent 06/08/2026
Gas Water/Sanitary
FiledStatusContractorScope
06/08/2026Permit IssuedAMERICAN STANDARD P&H CORGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/07/2026Pass-Final Curb Cut Non-Directive 14PassView ↗
07/15/2026Fail-Final Curb Cut Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
05/30/2026Fire-Resistant Penetrations and JointsRuoyu Weispecial
05/30/2026Energy Code Compliance InspectionsRuoyu Weiprogress
05/30/2026HVAC-R and service water heating equipmentRuoyu Weienergy_progress
05/30/2026HVAC-R and service water piping design and insulationRuoyu Weienergy_progress
05/30/2026HVAC-R and service water heating system controlsRuoyu Weienergy_progress
05/30/2026Maintenance informationRuoyu Weienergy_progress
05/30/2026Fire-Resistant Penetrations and JointsRuoyu Weispecial
05/30/2026FinalRuoyu Weiprogress
05/30/2026Energy Code Compliance InspectionsRuoyu Weiprogress
05/30/2026Fire-Resistance Rated ConstructionRuoyu Weiprogress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/16/2026B01409624-S1Request digital key ↗
08/16/2026B01409624-I1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature8
08/31/2026B01409624-I1Open ↗
08/31/2026B01409624-I1Open ↗
08/31/2026B01409624-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/16/2026B01409624-S1Open ↗
08/16/2026B01409624-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/31/2026B01409624-I1Open ↗
08/22/2026B01409624-S1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/16/2026B01409624-S1Open ↗
08/16/2026B01409624-I1Open ↗