← Back
Cape Cod
176-15 133 ROAD
QUEENS · BIN 4270544
💬 Discuss this project
1955Year Built
1.67Stories
A0Building Class
R3XZoning
1,449 sfGross Floor Area
1Units
Cape Cod · 4,000 sf lot · 0.36 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/21/2020$592K—Private party → Private party$409/sf building
12/22/2017$450K—— → —$311/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
UBS ENGINEERING111/02/2023
SEAD CONSULTING ENGINEERS108/16/2023
Building Lifecycle
All (21)Filed (2)Objection (5)Special Inspection (14)
11/02/2023
Filed — Alteration CO
Q00956283-I1
10/31/2023
Objection raised — Other
10/31/2023
Objection raised — Scope
10/18/2023
Objection resolved — Addressed
08/26/2023
Objection raised — Admin
08/26/2023
Objection raised — Zoning
08/16/2023
Filed — Alteration
ALTERATION APPLICATION FILED FOR HORIZONTAL REAR EXTENSION AND VERTICAL EXTENSION OF EXISTING 1 FAMILY 1-1/2 STORY FRAME BUILDING TO 2 FAMILY 2 STORY FRAME BUILDING AS PER ATTCHED PLANS.
Q00907293-I1
07/29/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
07/27/2023
Special inspection requirement — Concrete - Cast-In-Place
07/27/2023
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
07/27/2023
Special inspection requirement — Wood – Seismic Resistance
07/27/2023
Special inspection requirement — Subgrade Inspections
07/27/2023
Special inspection requirement — Fenestration areas
07/27/2023
Special inspection requirement — Insulation placement and R values
07/27/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
07/27/2023
Special inspection requirement — Fire-Resistance Rated Construction
07/27/2023
Special inspection requirement — Preliminary
07/27/2023
Special inspection requirement — Energy Code Compliance Inspections
07/27/2023
Special inspection requirement — Protection of exposed foundation insulation
07/20/2023
Special inspection requirement — Final
07/20/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nothing on file for this building.
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
07/29/2023Subsurface Investigations (Borings/Test Pits)—special
07/27/2023Concrete - Cast-In-Place—special
07/27/2023Excavations - Sheeting, Shoring, and Bracing—special
07/27/2023Wood – Seismic Resistance—special
07/27/2023Subgrade Inspections—special
07/27/2023Fenestration areas—energy_progress
07/27/2023Insulation placement and R values—energy_progress
07/27/2023Fenestration and door U-factor and product ratings—energy_progress
07/27/2023Fire-Resistance Rated Construction—progress
07/27/2023Preliminary—progress
07/27/2023Energy Code Compliance Inspections—progress
07/27/2023Protection of exposed foundation insulation—energy_progress
07/20/2023Final—progress
07/20/2023Structural Stability – Alterations of existing buildings—special
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026Q00907293-I1Request digital key ↗
08/23/2026Q00956283-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q00907293-I1Open ↗
08/13/2026Q00956283-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/23/2026Q00956283-I1Open ↗
08/13/2026Q00907293-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/23/2026Q00956283-I1Open ↗
08/13/2026Q00907293-I1Open ↗
▸Other Documents7
▸DOB NOWSite Survey: Initial2
08/13/2026Q00907293-I1Open ↗
08/13/2026Q00956283-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q00956283-I1Open ↗
08/13/2026Q00907293-I1Open ↗
▸DOB NOWPlot Diagram2
08/13/2026Q00956283-I1Open ↗
08/13/2026Q00907293-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/23/2026Q00956283-I1Open ↗