DOB07/29/2026REMEDY: FULLY DEMOLISH THE BUILDING AT 1760 ANTHONY AVENUE, BRONX GRADE AND FENCE SITE
DOB07/29/2026REMEDY: FULLY DEMOLISH THE BUILDING AT 1760 ANTHONY AVENUE, BRONX ENCE SITE
DOB07/29/2026FAILURE TO COMPLY W/COMMISSIONER'S ORDER #356764(112020FEU20508XC) DATED 11/20/2020 REQUIRING OWNERSHIP TO PERMANENTLY REPAIR THE RETAINING WAL UNDER PERMIT,STRTNG BY 02/01/2021.AS OF 07/29/2026,NO WORK PERMIT TO REPAIR THE RETAINING WALL HAVE BEEN OBTAIND.IMMEDIATELY COMPLY W/COMMISSIONER'S ORDER #356764(112020FEU20508XC)DATED 11/20/20
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB05/08/2025UNLAWFUL ACTS.FAIL TO COMPLY W/COMMISSIONE ORDER 081524CRW20501BH ISSU 8/15/2024. NO PERMITS OBTAINED TO REPAIR STRUCTURALLY COMPROMISED RW REMEDY:IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER 081524CRW20501BH ISSUED ON 8/15/2025. RW UNIT, 280 BROADWAY, NEW YORK, NY 10007. ATT: BILL HALKADAKIS, P.E
DOB08/15/2024EMERGENCY WORK & STABILIZATION. THE REAR OF BUILDING (EXPOSURE #3) IS STRUCTURALLY UNSTABLE DUE TO PREVIOUS COLLAPSE OF A RETAINING WALL ALONG THE READ CORNER OF BUILDING ALONG THE SOUTHEAST CORATER HAS FAILED & COULD COLLAPSE AT ANY TIME.REMEDY: IMMEDIATELY RETAIN A STRUCTURAL ENGINEER WITH DEMO/STABLIZATION NO LATER THAN 9/15/2024
DOB01/29/2024STRUCTURE RENDERED NON-COMPLIANT. A PARTIAL VACATE HAS BEEN SISSSUED O N 11-23-20 TO A VACANT MULTIPLE DWELLING IN WHICH THE REAR OF THE BUIL DING EXHIBITS STRUCTURAL DISREPAIR & SIGNS OF SIGNIFICANT MOVEMENT WI TH POTENTIAL OF COLAPSE. THE RETAINING WALL @ EXPOSUE 3 IS STRUCTALLY UNSAFE WITH POTENTIAL OF FURTHER COLLAPSE
DOB01/10/2024RETAINING WALL BETWEEN ANTHONY AVE AND CARTER AVE APPROXIMATELY OVER 150'-0" COLLAPSED. SECTION OF RETAINING WALL COLLAPSED ONTO CAR REPAIR SHOP AND DAMAGED REAR ROOF & WALL.
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
HPD01/19/2022§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT SOUTH YARD
HPD03/03/2021HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
HPD03/03/2021§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING (APPROX. 1 SQ.FT.) IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 14051554 ISSUED 03-MAR-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
HPD03/03/2021§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING & WALLS IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
HPD03/03/2021§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD TRIM AROUND NORTH WINDOW FRAME (FIRE ESCAPE) IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
HPD03/03/2021HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
DOB11/20/2020FTM:2 STORY+BSMT MASN WALLS WOOD FRAME FLRS RESID BLDG.REAR WALL SHOWS SIGNS&MOVEMT &CRACKS WERE OBSERVD @SOUTH EAST CORNR.SLAB ON GRADE@REAR HAS SETTLED.RETAIN WALL@REAR PROP LINE IN STATE DISRPR&BULG POTENT OF COLLAPSE.OWNER TO ENGAGE NYSPE TO EVALU THE BLDG&SUBMIT MONTHLY REPTS REPR BLDG&RETAIN WALL UNDER PERMIT.FILE BY 1/15/21.START WRK BY 2/1/21
DOB11/16/2020FAILURE TO MAINTAIN BUILDINGS IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED, VARIOUS CRACKS IN FOUNDATION WALLS AT EXPOSURE # 3 & 4 OF BOTH INSIDE & OUTSIDE, HALF INCH DEEP CRACKS ARE SEPARATE FROM CELLING AT INSIDE AND OUTSIDE ALSO AS SAME.
HPD01/12/2019§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING, AND WALLS. (APPROX. 4 SQ. FT.) IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
DOB07/22/1992V-DOB VIOLATION - ACTIVE