| Owner | Filings | Most Recent |
|---|---|---|
| DSNY | 8 | 09/03/2026 |
| NYC DEPARTMENT OF SANITATION | 1 | 03/22/2026 |
| DESIGN AND CONSTRUCTION | 1 | 03/21/2026 |
| NYC DEPT OF DESIGN & CONST. | 8 | 03/21/2026 |
| NYC DEPT DESIGN CONSTRUCTION | 2 | 03/21/2026 |
| NYC DEPARTMENT OF DESIGN CONST | 3 | 03/21/2026 |
| NYCDDC | 1 | 03/21/2026 |
| DCAS | 2 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| BURNS ENGINEERING, PC | 3 | 03/31/2025 |
| DATTNER ARCHITECTS | 1 | 03/28/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| WILLIAM VITACCO ASSOCIATES | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| ECHOSTAR CONSTRUCTION INC. | General Contractor | 2 | 08/14/2026 |
| COSIMO CURCIO | Electrical | 1 | 03/21/2026 |
| CURCIO COSIMO | Electrical | 1 | 03/21/2026 |
| DIMINO, THOMAS | Electrical | 1 | 03/21/2026 |
| DRANGEL, M | Electrical | 1 | 03/21/2026 |
| LIOTINE, VITO | Electrical | 1 | 03/21/2026 |
| PEREZ FELIZ, JOSE | Electrical | 1 | 03/21/2026 |
| REDMOND, LESLIE | Electrical | 1 | 03/21/2026 |
| BUNAY, CLEVER | Electrical | 1 | 03/21/2026 |
| GREEN MECHANICAL CORP | General Contractor | 1 | 09/03/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| TWIN PEAKS INC. | 317 | 3 | 03/31/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Permit Issued | GREEN MECHANICAL CORP | 09/02/2026 |
| DOB NOW | General Construction | Permit Issued | ECHOSTAR CONSTRUCTION INC. | 07/23/2026 |
| DOB NOW | Structural | Permit Issued | ECHOSTAR CONSTRUCTION INC. | 07/23/2026 |
| BIS | PL | ISSUED | KEW FOREST PLBG & HTG INC | 01/04/2018 |
| BIS | PL | ISSUED | KEW FOREST PLBG & HTG INC | 07/25/2016 |
| BIS | PL | ISSUED | KEW FOREST PLBG & HTG INC | 05/14/2015 |
| BIS | FB | ISSUED | S.J. FUEL CO., INC | 11/18/2014 |
| BIS | PL | ISSUED | KINGS PLAZA P & H INC | 11/18/2014 |
| BIS | OT | ISSUED | GLASS ARMOR OF NEW YORK I | 07/24/2013 |
| BIS | FP | ISSUED | ACTION FIRE SVC COMP INC | 07/12/2013 |
| BIS | OT | ISSUED | GLASS ARMOR OF NEW YORK I | 04/17/2013 |
| BIS | FS | ISSUED | JACK PICCINI, INC | 04/21/2011 |
| BIS | OT | ISSUED | GLASS ARMOR OF NEW YORK I | 09/07/2010 |
| BIS | OT | ISSUED | GLASS ARMOR OF NEW YORK I | 08/23/2010 |
| BIS | BL | ISSUED | JACK PICCINI, INC | 03/12/2007 |
| BIS | FP | ISSUED | CHIEF FIRE PRENVENTION & MECH | 09/16/2004 |
| BIS | OT | ISSUED | STATE ENVIRONMENTAL SVCS INC | 07/31/2000 |
| BIS | MH | ISSUED | J.T & T. AIR CONDITIONING CORP. | 08/02/1995 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 03/31/2025 | Permit Issued | GREEN MECHANICAL CORP | Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric TPLFYP008FM140A 8,013 BTU · Vrf Outdoor ×6 TPLFYP018FM140A 18,028 BTU · Vrf Indoor ×3 TPLFYP005FM140A 5,008 BTU · Fan Coil Indoor ×1 TURYP0723AN40AN 80,000 BTU · Condensing Unit ×1 Aaon RN-011 109,800 BTU · Rooftop Unit ×1 Trane YSC036 35,500 BTU · Condensing Unit ×1 Heating Ventilation Greenheck G-133-VG 2,175 CFM · Exhaust Fan ×4 G-240-C-VGD 7,000 CFM · Exhaust Fan ×4 G-300-C-VGD 9,000 CFM · Exhaust Fan ×4 GB-180-VGD 2,900 CFM · Exhaust Fan ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/31/2025 | — | — | Gas, Storm |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/10/2026 | Permit Issued | ZENA ELECTRIC INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/31/2025 | Permit Issued | GREEN MECHANICAL CORP | Steel |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 09/24/2024 | Maintenance information | MAXIM KORNGOLD | energy_progress |
| 09/24/2024 | Energy Code Compliance Inspections | MAXIM KORNGOLD | progress |
| 09/24/2024 | Duct leakage testing, insulation and design | MAXIM KORNGOLD | energy_progress |
| 09/24/2024 | Metering | MAXIM KORNGOLD | energy_progress |
| 09/24/2024 | HVAC-R and service water piping design and insulation | MAXIM KORNGOLD | energy_progress |
| 09/20/2024 | Insulation placement and R values | MAXIM KORNGOLD | energy_progress |
| 09/20/2024 | Air barrier — testing | MAXIM KORNGOLD | energy_progress |
| 09/20/2024 | Air barrier - visual inspection | MAXIM KORNGOLD | energy_progress |
| 09/20/2024 | Fenestration and door U-factor and product ratings | MAXIM KORNGOLD | energy_progress |
| 09/20/2024 | Fire-Resistant Penetrations and Joints | MAXIM KORNGOLD | special |
| 09/20/2024 | Energy Code Compliance Inspections | MAXIM KORNGOLD | progress |
| 09/20/2024 | Fenestration air leakage | MAXIM KORNGOLD | energy_progress |
| 08/27/2024 | Final | MAXIM KORNGOLD | progress |
| 08/27/2024 | Final | MAXIM KORNGOLD | progress |
| 08/27/2024 | Mechanical Systems | MAXIM KORNGOLD | special |