ECB08/10/20263314.4.4.9: obs active 8 story NB with exterior temporary equip. @ expo 1. Outrigger suspended scaff. Assembly installed @ expo 3. Upon review of the suspended scaffold motors, one motor was missing its identif$2K due
ECB05/20/20263314.6.2 failure to protect life lines from sharp edges and abrasion causing ahazardous condition for personnel/workers and public ,life lines in use were not protected of contact that includes roof top and bu$5K due
ECB05/20/20263314.15.2 observed suspended scaffold outriggers, ropes and rigging in place and readily available for use at 5TH floor roof, exposure 2. Stirrups installed approximately 3 feet and 2.5 feet from platform ends,$5K due
ECB05/20/2026Obs suspended scaffold installation not conforming to approved cd plans. Suspension lines installed with fiber rope in lieu of required 3/8" wire rope with fist grip clamps.tieback/outrigger assembly&rigging co$3K due
ECB05/20/20263314.10 observed outrigger beam installed not perpendicular to wall and not centered on pipe frame support. Beam shall be installed with all bearing supports perpendicular to beam centerline and maintained in v$5K due
ECB05/20/20263314.10.11 at time of inspection, suspended scaffold at exposure #1 observed not in use and not lowered to ground or deck as required. Scaffold left parked at expo:#2 5TH fl roof deck. No details provided to de$5K due
DOB11/14/2025Violation issued-failure to file 2024 external low pressure inspection
DOB09/23/2024Violation issued-failure to file 2023 external low pressure inspection
ECB05/20/2026Failure to maintain adequate housekeeping per section requirement.obs inadequate housekeeping throughout roof at exposures 2 & 4 at work areas.loose ropes,debris,panks,rubble,bucket and miscellaneous materialsHearing held — result not yet published
ECB12/29/2023At time of inspection, 20 cubic yards of combustible debris located at premises, a vacant lot, posing a fire and vermin infestation hazard to adjacent occupied premises, repair and/or replace; remove all debrisNothing owed — awaiting certificate of correction
ECB03/23/2013Failure to maintain bldg walls or appurtenances. Defects noted: facade(stucco) of the bldg at exposure #1 has a cracks from ground level to the roof level. Remedy: maintain exterior bldg wall.Nothing owed — awaiting certificate of correction
Old · issued 3+ years ago and still listed by DOB; nothing on the city's records either way
DOB06/30/2023Violation issued-failure to file 2020 external low pressure inspectionIssued 2023; DOB's record still lists it as active
DOB06/30/2023Violation issued-failure to file 2021 external low pressure inspectionIssued 2023; DOB's record still lists it as active
DOB06/20/2023Violation issued-failure to file 2019 external low pressure inspectionIssued 2023; DOB's record still lists it as active
DOB06/20/2023Violation issued-failure to file 2018 external low pressure inspectionIssued 2023; DOB's record still lists it as active
DOB04/25/2023Violation issued-failure to file 2022 external low pressure inspectionIssued 2023; DOB's record still lists it as active
DOB11/08/2019Violation issued for failure to file annual boiler 2017 inspection reportIssued 2019; DOB's record still lists it as active
DOB04/06/2018Violation issued for failure to file annual boiler 2016 inspection reportIssued 2018; DOB's record still lists it as active
DOB02/24/2017Violation issued for failure to file annual boiler 2015 inspection reportIssued 2017; DOB's record still lists it as active
Zoned commercial or Manhattan residential · Owner of record: Empire Development Fund · 12,467 sf lot · 0 FAR built · Flood zone X