← Back
Two stories - detached, small or mid-size
1767 EAST 51 STREET
BROOKLYN · Flatlands · BIN 3221005
💬 Discuss this project
1920Year Built
2Stories
A1Building Class
R3-2Zoning
1,092 sfGross Floor Area
1Units
4 Open Violations ▸FDNY Report ↗
Two stories - detached, small or mid-size · 3,000 sf lot · 0.36 FAR built · Flood zone X500
Locations of Work
General
Roof1p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/28/2018$515K—Private party → Private party$472/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC211/04/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AM EXPEDITING DRAFTING DESIGN403/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244111/04/2022
Building Lifecycle
All (53)Filed (2)Violation (5)Objection (27)Special Inspection (19)
10/09/2025
Violation issued (ECB, open)
Construction
01/20/2023
Objection raised — Zoning
01/20/2023
Objection raised — Zoning
01/20/2023
Objection resolved — Resolved
01/20/2023
Objection raised — Structural
01/20/2023
Objection raised — Structural
01/20/2023
Objection resolved — Addressed
01/20/2023
Objection raised — Structural
01/20/2023
Objection resolved — Addressed
01/20/2023
Objection raised — Structural
01/20/2023
Objection raised — Structural
01/20/2023
Objection raised — Structural
01/20/2023
Objection resolved — Resolved
01/20/2023
Objection raised — Other
01/20/2023
Objection raised — Other
01/20/2023
Objection raised — Zoning
11/17/2022
Objection raised — Other
11/17/2022
Objection resolved — Addressed
11/04/2022
Filed — Alteration CO
HEREWITH FILING TO LEGALIZE REAR EXTENSION AND NEW ROOF TO RESOLVE VIOLATIONS 35560507M & 355603616J AND OBTAIN NEW CERTIFICATE OF OCCUPANCY.
B00760891-I1
06/24/2022
Objection raised — Scope
06/24/2022
Objection resolved — Addressed
06/24/2022
Objection raised — Mechanical
06/24/2022
Objection resolved — Addressed
06/24/2022
Objection raised — Other
06/24/2022
Objection resolved — Addressed
06/24/2022
Objection raised — Other
06/24/2022
Objection resolved — Addressed
06/24/2022
Objection raised — Inspections
06/24/2022
Objection resolved — Addressed
06/20/2022
Special inspection requirement — Mechanical Systems
06/20/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
06/20/2022
Special inspection requirement — Final
NAVEEN KUMAR
06/20/2022
Special inspection requirement — Fenestration areas
NARESH MAHANGU
06/20/2022
Special inspection requirement — HVAC-R and service water heating equipment
NARESH MAHANGU
06/20/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
NARESH MAHANGU
06/20/2022
Special inspection requirement — HVAC-R and service water heating system controls
NARESH MAHANGU
06/20/2022
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
06/20/2022
Special inspection requirement — Insulation placement and R values
NARESH MAHANGU
06/20/2022
Special inspection requirement — Maintenance information
NARESH MAHANGU
06/20/2022
Special inspection requirement — Fenestration air leakage
NARESH MAHANGU
06/20/2022
Special inspection requirement — Electric vehicle service equipment requirements
NARESH MAHANGU
06/20/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
NARESH MAHANGU
06/17/2022
Filed — Alteration
FILING FOR REPLACEMENT OF PLUMBING FIXTURES ON EXISTING ROUGHING , ADD NEW FIXTURES AND REPLACE BOILER AND HOT WATER HEATER WITH ON DEMAND BOILER. NO CHANGE IN USE OCCUPANCY OR EGRESS.
B00655669-I1
12/31/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
12/31/2021
Special inspection requirement — Energy Code Compliance Inspections
12/31/2021
Special inspection requirement — HVAC-R and service water heating system controls
12/31/2021
Special inspection requirement — HVAC-R and service water heating equipment
12/31/2021
Special inspection requirement — Maintenance information
12/31/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
10/27/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/28/2021
Violation issued (ECB, open)
Construction
06/29/2021
Violation issued (ECB, closed)
Construction
06/29/2021
Violation issued (ECB, open)
Construction
Nothing on file for this building.
1 project · most recent 11/04/2022
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/04/2022——Heating Systems, Ventilation Systems
Heating
Panasonic FV-15VQ5 150 CFM · Exhaust Fan ×1
Ventilation
Panasonic FV-0510VS1 ( TYP.) 100 CFM · Exhaust Fan ×5
1 project · most recent 06/17/2022
Gas Water/Sanitary
FiledStatusContractorScope
06/17/2022——Gas, Water/Sanitary
1 project · most recent 11/04/2022
Wood
FiledStatusContractorScope
11/04/2022——Wood
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
06/20/2022Mechanical Systems—special
06/20/2022Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
06/20/2022FinalNAVEEN KUMARprogress
06/20/2022Fenestration areasNARESH MAHANGUenergy_progress
06/20/2022HVAC-R and service water heating equipmentNARESH MAHANGUenergy_progress
06/20/2022HVAC-R and service water piping design and insulationNARESH MAHANGUenergy_progress
06/20/2022HVAC-R and service water heating system controlsNARESH MAHANGUenergy_progress
06/20/2022Air barrier - visual inspectionNARESH MAHANGUenergy_progress
06/20/2022Insulation placement and R valuesNARESH MAHANGUenergy_progress
06/20/2022Maintenance informationNARESH MAHANGUenergy_progress
06/20/2022Fenestration air leakageNARESH MAHANGUenergy_progress
06/20/2022Electric vehicle service equipment requirementsNARESH MAHANGUenergy_progress
06/20/2022Fenestration and door U-factor and product ratingsNARESH MAHANGUenergy_progress
12/31/2021Fire-Resistant Penetrations and Joints—special
12/31/2021Energy Code Compliance Inspections—progress
12/31/2021HVAC-R and service water heating system controls—energy_progress
12/31/2021HVAC-R and service water heating equipment—energy_progress
12/31/2021Maintenance information—energy_progress
12/31/2021HVAC-R and service water piping design and insulation—energy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/29/2026B00655669-I1Request digital key ↗
08/15/2026B00760891-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B00760891-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B00760891-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/29/2026B00655669-I1Open ↗
08/28/2026B00760891-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/29/2026B00655669-I1Open ↗
08/15/2026B00760891-I1Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification1
08/15/2026B00760891-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B00760891-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B00760891-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026B00760891-I1Open ↗