← Back
General warehouse
178 ALABAMA AVENUE
BROOKLYN · East New York (North) · BIN 3843016
💬 Discuss this project
0Year Built
1Stories
E1Building Class
M1-4Zoning
5,495 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
General warehouse · Owner of record: CRCG REALTY LLC · 10,000 sf lot · 0.55 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingFire Protection
Roof2p · 1 filing · 5 docs
Bulkhead1p · 1 filing · 2 docs
Floor 13p · 3 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SELF EMPLOYED N A1003/21/2026
BROOKLYN SOLARWORKS203/21/2026
H2 CONSULTING PE PC1603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SALVATORE BASILE II INCGeneral Contractor1007/08/2026
BROOKLYN SOLARWORKS LLCGeneral Contractor203/21/2026
JOHN'S PLBG & HTG, INCPlumbing207/08/2026
BROOKYLN SOLARWORKS, LLCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244204/07/2025
H2 CONSULTING PE PC835401/30/2024
Building Lifecycle
All (57)Filed (15)Permit Issued (9)Signed Off (6)Inspection (4)Objection (4)Special Inspection (19)
06/17/2025
Signed off — Alteration
INSTALL PLUMBING FIXTURES FOR A BUILDING MATERIALS AND CONTRACTOR YARD ESTIBLISHMENT.
B00873969-I1
06/17/2025
Signed off — Alteration
INSTALL NEW 19' CURB CUT (INCLUDING TWO 1'-6" SPLAY) IN CONJUNCTION W/ B00856444.
B00903112-I1
06/17/2025
Signed off — Alteration
INSTALL NEW 20' CURB CUT (INCLUDING TWO 1'-6" SPLAY) IN CONJUNCTION W/ B00856444.
B00970031-I1
04/30/2025
Signed off — Alteration
INSTALL SOLAR PV SYSTEM ON THE EXISTING ROOFTOP. NO CHANGES TO USE, EGRESS OR OCCUPANCY.
B01055143-I1
04/07/2025
Filed — Alteration
INSTALL SOLAR PV SYSTEM ON THE EXISTING ROOFTOP. NO CHANGES TO USE, EGRESS OR OCCUPANCY.
B01055143-P1
04/07/2025
Special inspection requirement — Final
NARESH MAHANGU
04/07/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
04/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
04/07/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
04/07/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
04/04/2025
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
12/03/2024
Permit issued — Curb Cut
B00903112-I1-CC
12/03/2024
Permit issued — Curb Cut
B00970031-I1-CC
11/27/2024
Signed off — Alteration
INSTALL TEMPORARY CONSTRUCTION WOOD FENCE.
B00856379-I1
11/27/2024
Signed off — Alteration
ERECT FOUNDATION AND SUPER STRUCTURAL IN CONJUNCTION WITH B00856444-I1.
B00873616-I1
08/09/2024
Permit issued — Structural
B00873616-I1-GC-CX
06/06/2024
Permit issued — Solar
B01055143-I1-SL
06/06/2024
Objection resolved — Addressed
06/05/2024
Objection resolved — Addressed
05/31/2024
Objection raised — Other
05/31/2024
Objection raised — Other
05/28/2024
Filed — Alteration
INSTALL SOLAR PV SYSTEM ON THE EXISTING ROOFTOP. NO CHANGES TO USE, EGRESS OR OCCUPANCY.
B01055143-I1
04/09/2024
Permit issued — Construction Fence
B00856379-I1-FN
03/25/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/07/2024
Permit issued — Plumbing
B00873969-I1-PL
01/30/2024
Filed — Alteration
INSTALL PLUMBING FIXTURES FOR A BUILDING MATERIALS AND CONTRACTOR YARD ESTIBLISHMENT.
B00873969-P2
01/29/2024
Special inspection requirement — Energy Code Compliance Inspections
Harry Hong
01/29/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Harry Hong
01/19/2024
Filed — Alteration
INSTALL PLUMBING FIXTURES FOR A BUILDING MATERIALS AND CONTRACTOR YARD ESTIBLISHMENT.
B00873969-P1
12/20/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Harry Hong
12/20/2023
Special inspection requirement — Energy Code Compliance Inspections
Harry Hong
12/14/2023
Filed — Alteration
INSTALL NEW 19' CURB CUT (INCLUDING TWO 1'-6" SPLAY) IN CONJUNCTION W/ B00856444.
B00903112-I1
12/14/2023
Filed — Alteration
INSTALL NEW 20' CURB CUT (INCLUDING TWO 1'-6" SPLAY) IN CONJUNCTION W/ B00856444.
B00970031-I1
12/08/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/08/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
12/04/2023
Permit issued — Plumbing
B00873969-I1-PL
10/24/2023
Filed — Alteration
INSTALL TEMPORARY CONSTRUCTION WOOD FENCE.
B00856379-P1
09/08/2023
Permit issued — General Construction
B00873616-I1-GC-CX
08/28/2023
Filed — Alteration
INSTALL PLUMBING FIXTURES FOR A BUILDING MATERIALS AND CONTRACTOR YARD ESTIBLISHMENT.
B00873969-I1
08/28/2023
Filed — Alteration
ERECT FOUNDATION AND SUPER STRUCTURAL IN CONJUNCTION WITH B00856444-I1.
B00873616-I1
05/11/2023
Special inspection requirement — Structural Steel - Details
Harry Hong
05/11/2023
Special inspection requirement — Footing and Foundation
Harry Hong
05/11/2023
Special inspection requirement — Masonry
Harry Hong
05/11/2023
Special inspection requirement — Structural Cold-Formed Steel
Harry Hong
05/11/2023
Special inspection requirement — Concrete - Cast-In-Place
Harry Hong
05/11/2023
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Harry Hong
05/11/2023
Special inspection requirement — Structural Steel - High Strength Bolting
Harry Hong
05/11/2023
Special inspection requirement — Structural Steel - Welding
Harry Hong
05/11/2023
Special inspection requirement — Subgrade Inspections
Harry Hong
05/11/2023
Special inspection requirement — Final
Harry Hong
04/12/2023
Permit issued — Construction Fence
B00856379-I1-FN
04/06/2023
Filed — Alteration
INSTALL TEMPORARY CONSTRUCTION WOOD FENCE.
B00856379-I1
09/29/2019
Filed — Alteration
B00210637-I1
09/10/2019
Filed — Alteration
8 FT HIGH PLYWOOD CONSTRUCTION FENCE AROUND PERIMETER ON THE PROPERTY LINE AND EXTENDING 5' AT FRONT OF PROPERTY
B00162069-P1
08/26/2019
Filed — Alteration
(1) NEW 15' CURB CUT WITH (2) 2'6" SPLAYS FOR NEW BLDG # 321968242
B00203075-I1
08/21/2019
Filed — Alteration
B00203093-I1
05/20/2019
Filed — Alteration
8 FT HIGH PLYWOOD CONSTRUCTION FENCE AROUND PERIMETER ON THE PROPERTY LINE AND EXTENDING 5' AT FRONT OF PROPERTY
B00162069-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutSigned-offSALVATORE BASILE II INC12/03/2024
DOB NOWCurb CutSigned-offSALVATORE BASILE II INC12/03/2024
DOB NOWStructuralSigned-offSALVATORE BASILE II INC08/09/2024
DOB NOWSolarSigned-offBROOKLYN SOLARWORKS LLC06/06/2024
DOB NOWConstruction FenceSigned-offSALVATORE BASILE II INC04/09/2024
DOB NOWPlumbingSigned-offG.A. PLBG & HTG INC03/07/2024
DOB NOWPlumbingSigned-offG.A. PLBG & HTG INC12/04/2023
DOB NOWGeneral ConstructionSigned-offSALVATORE BASILE II INC09/08/2023
DOB NOWConstruction FenceSigned-offSALVATORE BASILE II INC04/12/2023
2 projects · most recent 05/22/2024
General Wiring
FiledStatusContractorScope
05/22/2024CompleteBROOKYLN SOLARWORKS, LLC—
04/24/2024CompleteNAPSTAR ELECTRIC INCGeneral Wiring
1 project · most recent 09/10/2019
Fence
FiledStatusContractorScope
09/10/2019——Fence
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
04/04/2025Pass-Final Curb Cut Non-Directive 14PassView ↗
03/25/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/08/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
12/08/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
04/07/2025FinalNARESH MAHANGUprogress
04/07/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
04/07/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
04/07/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
04/07/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
01/29/2024Energy Code Compliance InspectionsHarry Hongprogress
01/29/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationHarry Hongspecial
12/20/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationHarry Hongspecial
12/20/2023Energy Code Compliance InspectionsHarry Hongprogress
05/11/2023Structural Steel - DetailsHarry Hongspecial
05/11/2023Footing and FoundationHarry Hongprogress
05/11/2023MasonryHarry Hongspecial
05/11/2023Structural Cold-Formed SteelHarry Hongspecial
05/11/2023Concrete - Cast-In-PlaceHarry Hongspecial
05/11/2023Excavations - Sheeting, Shoring, and BracingHarry Hongspecial
05/11/2023Structural Steel - High Strength BoltingHarry Hongspecial
05/11/2023Structural Steel - WeldingHarry Hongspecial
05/11/2023Subgrade InspectionsHarry Hongspecial
05/11/2023FinalHarry Hongprogress
▾Documents — 48 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch8
08/27/2026B00856379-I1Request digital key ↗
08/27/2026B00856379-P1Request digital key ↗
08/26/2026B00873616-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸DOB NOWPlans/Sketch - Curb Cut3
09/02/2026B00203093-I1Request digital key ↗
09/02/2026B00203075-P1Request digital key ↗
09/02/2026B00203075-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence2
09/02/2026B00162069-I1Request digital key ↗
08/15/2026B00162069-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler1
09/02/2026B00210637-I1Request digital key ↗
▸Seals & Professional Certifications31
▸DOB NOWDPL-1: Design Professional Seal & Signature14
09/02/2026B00162069-I1Open ↗
09/02/2026B00162069-P1Open ↗
08/27/2026B00856379-P1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature11
09/01/2026B00873969-P2Open ↗
08/25/2026B01055143-P1Open ↗
08/23/2026B00873969-P1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026B00873969-P2Open ↗
08/25/2026B01055143-P1Open ↗
08/25/2026B01055143-P1Open ↗
Showing 3 of 6 on file for this type
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01055143-I1Open ↗
▸Other Documents2
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00873616-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B00873616-I1Open ↗