← Back
Three families
178 COFFEY STREET
💬 Discuss this project
1899Year Built
2Stories
C0Building Class
M1-1Zoning
3,000 sfGross Floor Area
3Units
Rent Stabilized14 Open Violations ▸
Three families · Owner of record: 178 COFFEY STREET LLC · 2,000 sf lot · 1.5 FAR built · Flood zone X500
Locations of Work
Plumbing
Floor 21p · 1 filing · 8 docs
Floor 1
Basement1p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PIONEER & KING LLC703/22/2026
178 COFFEY STREET LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/13/2020$2.2M—Private party → 178 COFFEY STREET LLC$733/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FORM FUNCTION ARCHITECTS, LLC207/12/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB BUILDING CONSULTING203/21/2026
L & J DESIGN GROUP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A&E ELECTRICAL SYSTEMS COElectrical103/22/2026
EH PLUMBING & HEATING CORPlumbing107/08/2026
Building Lifecycle
All (22)Filed (2)Permit Issued (1)Signed Off (1)Violation (16)Special Inspection (2)
05/04/2026
Violation issued (HPD, open)
A
11/20/2025
Violation issued (HPD, open)
I
06/09/2025
Violation issued (HPD, open)
A
11/29/2024
Violation issued (HPD, open)
I
04/09/2024
Violation issued (HPD, open)
A
01/04/2024
Signed off — Alteration
REMOVAL AND INSTALLATION OF PLUMBING FIXTURES AS PER PLANS.
B00480618-I1
11/22/2023
Violation issued (HPD, open)
I
03/22/2023
Violation issued (HPD, open)
A
11/14/2022
Violation issued (HPD, open)
I
07/13/2022
Special inspection requirement — Energy Code Compliance Inspections
Thomas Klaber
07/12/2022
Filed — Alteration
REMOVAL AND INSTALLATION OF PLUMBING FIXTURES AS PER PLANS.
B00480618-P1
07/07/2022
Special inspection requirement — Energy Code Compliance Inspections
JIN KWON KIM
02/23/2022
Violation issued (HPD, open)
I
02/23/2022
Violation issued (HPD, open)
A
04/07/2021
Permit issued — Plumbing
B00480618-I1-PL
04/07/2021
Violation issued (HPD, open)
I
04/07/2021
Violation issued (HPD, open)
A
03/24/2021
Filed — Alteration
REMOVAL AND INSTALLATION OF PLUMBING FIXTURES AS PER PLANS.
B00480618-I1
10/08/2015
Violation issued (HPD, closed)
I
01/29/2001
Violation issued (HPD, open)
B
04/11/1997
Violation issued (HPD, closed)
A
06/03/1987
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offEH PLUMBING & HEATING COR04/07/2021
BISOTISSUEDRADEK SZCZESNY11/04/2022
BISOTISSUEDNY NJ RESTORATION INC08/04/2021
BISOTISSUEDNY NJ RESTORATION INC01/15/2021
BISOTISSUEDN/A01/15/2002
BISOTISSUEDN/A07/03/2000
1 project · most recent 03/15/2021
General Wiring
FiledStatusContractorScope
03/15/2021Permit IssuedA&E ELECTRICAL SYSTEMS COGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
07/13/2022Energy Code Compliance InspectionsThomas Klaberprogress
07/07/2022Energy Code Compliance InspectionsJIN KWON KIMprogress
▾Documents — 41 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/29/2026B00480618-P1Request digital key ↗
08/29/2026B00480618-I1Request digital key ↗
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION3
03/07/2022340771196Open ↗
11/12/2020340771196Open ↗
10/09/2020340771196Open ↗
▸BISWORK PERMIT APPLICATION3
11/30/2022340771196Open ↗
11/01/2022340771196Open ↗
01/15/2021340771196Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/29/2026B00480618-I1Open ↗
08/29/2026B00480618-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B00480618-P1Open ↗
08/30/2026B00480618-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
10/09/2020340771196Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/09/2020340771196Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
11/12/2020340771196Open ↗
▸Environmental & Asbestos4
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
10/29/2020340771196Open ↗
10/09/2020340771196Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/29/2026B00480618-I1Open ↗
08/29/2026B00480618-P1Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
11/10/2023340771196Open ↗
01/15/2021340771196Open ↗
10/09/2020340771196Open ↗
▸BISINTERIOR LIGHTING POWER1
11/10/2023340771196Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
11/15/2023340771196Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
09/07/2022340771196Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
11/10/2023340771196Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/09/2020340771196Open ↗
▸Inspections & Test Reports6
▸BISTECHNICAL REPORT: RESPONSIBILITY5
01/05/2024340771196Open ↗
01/05/2024340771196Open ↗
11/10/2023340771196Open ↗
Showing 3 of 5 on file for this type
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
01/05/2024340771196Open ↗
▸Approvals, Objections & Sign-offs3
▸BISSUPERSEDING LETTER1
11/30/2022340771196Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
01/08/2024340771196Open ↗
▸BISFINAL1
11/10/2023340771196Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
10/30/2020340771196Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
11/10/2023340771196Open ↗
▸Filing & Intake Forms3
▸BISBOROUGH INTAKE FORM1
11/30/2022340771196Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/09/2020340771196Open ↗
▸BISADDITIONAL INFORMATION1
06/09/2022340771196Open ↗