← Back
One family attached or semi-detached
179-53 SELOVER ROAD
QUEENS · BIN 4269539
💬 Discuss this project
1935Year Built
2Stories
A5Building Class
R4BZoning
1,440 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One family attached or semi-detached · 2,000 sf lot · 0.72 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 9 docs
Floor 11p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/29/2016$409K—— → —$284/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC104/08/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
THE GREEN PLUG LLCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854104/08/2025
Building Lifecycle
All (9)Filed (1)Permit Issued (1)Signed Off (1)Violation (1)Special Inspection (5)
05/15/2025
Signed off — Alteration
INSTALLATION OF PV SYSTEM ON EXISTING ROOFTOP. NO CHANGES TO EGRESS OR USE OF OCCUPANCY.
Q01207672-I1
04/14/2025
Permit issued — Solar
Q01207672-I1-SL
04/08/2025
Filed — Alteration
INSTALLATION OF PV SYSTEM ON EXISTING ROOFTOP. NO CHANGES TO EGRESS OR USE OF OCCUPANCY.
Q01207672-I1
04/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
04/08/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
04/08/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
04/08/2025
Special inspection requirement — Final
TOM PETERSEN
04/08/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
09/10/2008
Violation issued (ECB, closed)
Unknown
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offTHE GREEN PLUG LLC04/14/2025
2 projects · most recent 04/07/2025
General Wiring
FiledStatusContractorScope
04/07/2025CompleteLAURI ELECTRICAL INCGeneral Wiring
04/04/2025CompleteLAURI ELECTRICAL INC—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/08/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
04/08/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
04/08/2025Energy Code Compliance InspectionsTOM PETERSENprogress
04/08/2025FinalTOM PETERSENprogress
04/08/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026Q01207672-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026Q01207672-I1Open ↗
08/25/2026Q01207672-I1Open ↗
08/25/2026Q01207672-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026Q01207672-I1Open ↗
08/25/2026Q01207672-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/20/2026Q01207672-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/20/2026Q01207672-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01207672-I1Open ↗