← Back
Primarily 2 family with 1 store or office
179 MOTT STREET
MANHATTAN · BIN 1007189
💬 Discuss this project
1900Year Built
4Stories
S2Building Class
C6-1Zoning
5,854 sfGross Floor Area
3Units
0 Open Violations
Primarily 2 family with 1 store or office · 1,250 sf lot · 4.68 FAR built · Flood zone X
Locations of Work
Architecture
Roof1 filing · 20 docs
Floor 41 filing · 20 docs
Floor 31 filing · 20 docs
Floor 21 filing · 20 docs
Floor 11 filing · 20 docs
Cellar1 filing · 20 docs
1 job · most recent 04/04/2024
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
04/04/2024Signed-offTRISTAR DEVELOPING INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MSZ-GL09NAU1 9,000 BTU · Fan Coil Indoor ×16
MSZ-GL12NAU1 12,000 BTU · Fan Coil Indoor ×10
MSZ-GL15NAU1 14,000 BTU · Fan Coil Indoor ×4
MSZ-GL18NAU1 18,000 BTU · Fan Coil Indoor ×4
MXZ-SM42NAMHZ 42,000 BTU · Condensing Unit ×7
MSZ-GL06NAU1 6,000 BTU · Fan Coil Indoor ×2
MXZ-3C24NAHZ3 2 tons · Condensing Unit ×2
MXZ-3C30NAHZ3 28,400 BTU · Condensing Unit ×2
MXZ-SM36NAMHZ 36,000 BTU · Condensing Unit ×8
MSZ-GL12NA 12,000 BTU · Fan Coil Indoor ×9
MSZ-GL15NA 14,000 BTU · Fan Coil Indoor ×9
MSZ-GL09NA 9,000 BTU · Fan Coil Indoor ×6
MSZ-GL24NA 22,400 BTU · Fan Coil Indoor ×6
MXZ-SM48NAMHZ 48,000 BTU · Condensing Unit ×3
1 job · most recent 04/04/2024
Gas Water/Sanitary
FiledStatusContractorScope
04/04/2024Signed-offTRI CITY MECHANICAL GROUPGas, Water/Sanitary
2 jobs · most recent 07/19/2023
General Wiring
FiledStatusContractorScope
07/19/2023CompleteKJK ELECTRIC INCGeneral Wiring
07/19/2023CompleteKJK ELECTRIC INC4 meters
1 job · most recent 04/04/2024
Wood
FiledStatusContractorScope
04/04/2024Signed-offTRISTAR DEVELOPING INCWood
Building Lifecycle
All (73)Filed (9)Permit Issued (4)Signed Off (3)Violation (3)Inspection (4)Objection (20)Special Inspection (30)
04/04/2024
Filed — Alteration CO
EXISTING COMMERCIAL & ONE FAMILY 4-STORY BUILDING CONVERT TO COMMERCIAL & 2-FAMILY WITH PARTITION AND MECHINICAL WORK AS PER PLAN. OBTIAN A NEW CO.
M00754211-P6
03/01/2024
Special inspection requirement — Air barrier - visual inspection
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Duct leakage testing, insulation and design
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Mechanical Systems
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Energy Code Compliance Inspections
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Final
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Fire-Resistance Rated Construction
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — HVAC-R and service water heating equipment
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Fenestration areas
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Fenestration air leakage
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Interior lighting power
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Lighting controls
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Insulation placement and R values
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Maintenance information
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — HVAC-R and service water heating system controls
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Lighting in dwelling units
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Metering
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Shutoff dampers
CHRISTIAN LOZADA
03/01/2024
Special inspection requirement — Exterior lighting power
CHRISTIAN LOZADA
01/19/2024
Signed off — Alteration
M08025394-I1
01/09/2024
Special inspection requirement — Insulation placement and R values
01/09/2024
Special inspection requirement — Shutoff dampers
11/09/2023
Objection resolved — Addressed
11/08/2023
Objection raised — Admin
11/03/2023
Filed — Alteration CO
EXISTING COMMERCIAL & ONE FAMILY 4-STORY BUILDING CONVERT TO COMMERCIAL & 2-FAMILY WITH PARTITION AND MECHINICAL WORK AS PER PLAN. OBTIAN A NEW CO.
M00754211-P5
10/13/2023
Signed off — Alteration CO
EXISTING COMMERCIAL & ONE FAMILY 4-STORY BUILDING CONVERT TO COMMERCIAL & 2-FAMILY WITH PARTITION AND MECHINICAL WORK AS PER PLAN. OBTIAN A NEW CO.
M00754211-S3
10/11/2023
Special inspection requirement — Lighting in dwelling units
CHRISTIAN LOZADA
10/11/2023
Special inspection requirement — Metering
CHRISTIAN LOZADA
10/11/2023
Special inspection requirement — Fenestration areas
CHRISTIAN LOZADA
10/11/2023
Special inspection requirement — HVAC-R and service water heating equipment
CHRISTIAN LOZADA
10/11/2023
Special inspection requirement — Interior lighting power
CHRISTIAN LOZADA
10/11/2023
Special inspection requirement — HVAC-R and service water heating system controls
CHRISTIAN LOZADA
10/02/2023
Filed — Alteration CO
EXISTING COMMERCIAL & ONE FAMILY 4-STORY BUILDING CONVERT TO COMMERCIAL & 2-FAMILY WITH PARTITION AND MECHINICAL WORK AS PER PLAN. OBTIAN A NEW CO.
M00754211-P4
09/11/2023
Objection resolved — Addressed
08/31/2023
Objection raised — Admin
08/28/2023
Filed — Alteration CO
EXISTING COMMERCIAL & ONE FAMILY 4-STORY BUILDING CONVERT TO COMMERCIAL & 2-FAMILY WITH PARTITION AND MECHINICAL WORK AS PER PLAN. OBTIAN A NEW CO.
M00754211-P3
07/05/2023
Signed off — Alteration CO
EXISTING COMMERCIAL & ONE FAMILY 4-STORY BUILDING CONVERT TO COMMERCIAL & 2-FAMILY WITH PARTITION AND MECHINICAL WORK AS PER PLAN. OBTIAN A NEW CO.
M00754211-S1
06/27/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/27/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/24/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/07/2022
Permit issued — Construction Fence
M08025394-I1-FN
10/24/2022
Filed — Alteration
M08025394-I1
10/24/2022
Objection resolved — Addressed
10/21/2022
Permit issued — Structural
M00754211-S3-ST
10/19/2022
Objection raised — Admin
10/18/2022
Permit issued — Plumbing
M00754211-S1-PL
10/17/2022
Filed — Alteration CO
EXISTING COMMERCIAL & ONE FAMILY 4-STORY BUILDING CONVERT TO COMMERCIAL & 2-FAMILY WITH PARTITION AND MECHINICAL WORK AS PER PLAN. OBTIAN A NEW CO.
M00754211-P1
10/17/2022
Permit issued — General Construction
M00754211-I1-GC-CX
10/12/2022
Filed — Alteration CO
EXISTING COMMERCIAL & ONE FAMILY 4-STORY BUILDING CONVERT TO COMMERCIAL & 2-FAMILY WITH PARTITION AND MECHINICAL WORK AS PER PLAN. OBTIAN A NEW CO.
M00754211-S3
08/29/2022
Objection resolved — Addressed
08/24/2022
Objection resolved — Addressed
08/19/2022
Objection resolved — Addressed
08/17/2022
Objection raised — Inspections
08/15/2022
Objection raised — Admin
Latest 60 of 73 events.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/31/2024$4.5M—— → —$769/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
THOMAS C. TUNG, P.E.704/04/2024
JUST CONSULTING ENGINEERING210/02/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WM ARCH1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRISTAR DEVELOPING INCGeneral Contractor407/08/2026
KJK ELECTRIC INCElectrical103/22/2026
TRI CITY MECHANICAL GROUP CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781604/04/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FenceSigned-offTRISTAR DEVELOPING INC11/07/2022
DOB NOWStructuralSigned-offTRISTAR DEVELOPING INC10/21/2022
DOB NOWPlumbingSigned-offFLAVIO MECHANICAL CORP10/18/2022
DOB NOWGeneral ConstructionPermit IssuedTRISTAR DEVELOPING INC10/17/2022
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
06/27/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/27/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/24/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/24/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 54
DateRequirementInspectorRole
03/01/2024Air barrier - visual inspectionCHRISTIAN LOZADAenergy_progress
03/01/2024Duct leakage testing, insulation and designCHRISTIAN LOZADAenergy_progress
03/01/2024Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
03/01/2024Mechanical SystemsCHRISTIAN LOZADAspecial
03/01/2024Structural Stability – Alterations of existing buildingsCHRISTIAN LOZADAspecial
03/01/2024Energy Code Compliance InspectionsCHRISTIAN LOZADAprogress
03/01/2024FinalCHRISTIAN LOZADAprogress
03/01/2024Fire-Resistance Rated ConstructionCHRISTIAN LOZADAprogress
03/01/2024HVAC-R and service water heating equipmentCHRISTIAN LOZADAenergy_progress
03/01/2024Fenestration areasCHRISTIAN LOZADAenergy_progress
03/01/2024Fenestration air leakageCHRISTIAN LOZADAenergy_progress
03/01/2024Interior lighting powerCHRISTIAN LOZADAenergy_progress
03/01/2024Lighting controlsCHRISTIAN LOZADAenergy_progress
03/01/2024Insulation placement and R valuesCHRISTIAN LOZADAenergy_progress
03/01/2024Maintenance informationCHRISTIAN LOZADAenergy_progress
03/01/2024HVAC-R and service water heating system controlsCHRISTIAN LOZADAenergy_progress
03/01/2024HVAC-R and service water piping design and insulationCHRISTIAN LOZADAenergy_progress
03/01/2024Lighting in dwelling unitsCHRISTIAN LOZADAenergy_progress
03/01/2024MeteringCHRISTIAN LOZADAenergy_progress
03/01/2024Fenestration and door U-factor and product ratingsCHRISTIAN LOZADAenergy_progress
03/01/2024Shutoff dampersCHRISTIAN LOZADAenergy_progress
03/01/2024Exterior lighting powerCHRISTIAN LOZADAenergy_progress
01/09/2024Insulation placement and R values—energy_progress
01/09/2024Shutoff dampers—energy_progress
10/11/2023Lighting in dwelling unitsCHRISTIAN LOZADAenergy_progress
Latest 25 of 54.
▾Documents — 74 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
09/01/2026M00754211-P4Request digital key ↗
09/01/2026M00754211-P6Request digital key ↗
09/01/2026M00754211-S3Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
11/08/2023141021203Open ↗
02/14/2023141021203Open ↗
▸BISBPP-DOT: SIDEWALK/CURB/ROAD WORK PERMITS1
11/20/2023141021203Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
06/13/2023141021203Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZoning Exhibit form (1-5)5
09/01/2026M00754211-P6Open ↗
08/15/2026M00754211-P1Open ↗
08/15/2026M00754211-P5Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026M00754211-I1Open ↗
▸Seals & Professional Certifications24
▸DOB NOWProgress Inspector Seal & Signature10
09/01/2026M00754211-P4Open ↗
08/31/2026M00754211-S3Open ↗
08/31/2026M00754211-P6Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/01/2026M00754211-I1Open ↗
09/01/2026M00754211-P3Open ↗
09/01/2026M00754211-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/31/2026M00754211-P6Open ↗
08/30/2026M00754211-S1Open ↗
08/27/2026M00754211-P5Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/14/2023141021203Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
02/14/2023141021203Open ↗
▸Safety & Tenant Protection11
▸DOB NOWStreet Tree Checklist5
09/01/2026M00754211-P6Open ↗
08/15/2026M00754211-P1Open ↗
08/15/2026M00754211-P5Open ↗
Showing 3 of 5 on file for this type
▸BISBPP: STREET TREES SITE PLAN1
02/14/2023141021203Open ↗
▸BISSTREET TREE CHECKLIST1
02/14/2023141021203Open ↗
▸BISSTREET TREE SIGNOFF1
11/16/2023141021203Open ↗
▸DOB NOWStreet Trees Site Plan1
08/15/2026M00754211-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/15/2026M00754211-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/15/2026M00754211-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form3
09/01/2026M00754211-S3Open ↗
08/15/2026M00754211-S1Open ↗
08/15/2026M00754211-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/15/2026M00754211-I1Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
02/14/2023141021203Open ↗
▸Approvals, Objections & Sign-offs1
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
11/20/2023141021203Open ↗
▸Cost, Insurance & Ownership1
▸BISBPP-11 - Affidavit as to Roadway Pavement And/Or Sidewalk and Curb Construction1
11/20/2023141021203Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION1
11/13/2023141021203Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
02/14/2023141021203Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
02/14/2023141021203Open ↗
▸Other Documents9
▸DOB NOWProperty Ownership Certification5
09/01/2026M00754211-P6Open ↗
08/15/2026M00754211-P1Open ↗
08/15/2026M00754211-P5Open ↗
Showing 3 of 5 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION2
11/20/2023141021203Open ↗
11/20/2023141021203Open ↗
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
11/20/2023141021203Open ↗
▸DOB NOWFinal Survey1
08/15/2026M00754211-I1Open ↗