← Back
Two family converted from one family
18-29 25 ROAD
QUEENS · BIN 4019973
💬 Discuss this project
1920Year Built
1Stories
B3Building Class
R4Zoning
1,100 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 2,500 sf lot · 0.44 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Permit Issued — active, not yet Signed-off
Floor 1Under Construction5p · 1 filing · 19 docs
Sub-BasementUnder Construction2p · 1 filing · 19 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/19/2025$950K—Private party → Private party$864/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HC ARCHITECT, PC403/24/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ZIUM ARCH403/21/2026
LDC CONSULTANTS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
URBAN MOONSTER CON CORPGeneral Contractor407/08/2026
I DO PLUMBING & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BEYOND ARCH LLC3600203/24/2026
SEAD ENGINEERING PC2665110/29/2025
Building Lifecycle
All (24)Filed (4)Permit Issued (5)Violation (2)Inspection (3)Special Inspection (10)
05/04/2026
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
04/16/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/16/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Hackjong Choi
04/03/2026
Special inspection requirement — Energy Code Compliance Inspections
Hackjong Choi
04/03/2026
Special inspection requirement — HVAC-R and service water heating system controls
Hackjong Choi
04/03/2026
Special inspection requirement — HVAC-R and service water heating equipment
Hackjong Choi
04/03/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Hackjong Choi
03/24/2026
Filed — Alteration
INSTALLATION AND REMOVAL OF PLUMBING FIXTURES IN THE EXISTING 2-FAMILY HOUSE.
Q01280797-P1
03/04/2026
Permit issued — Structural
Q01280797-S2-ST
03/04/2026
Permit issued — General Construction
Q01280797-I1-GC
02/23/2026
Permit issued — Plumbing
Q01280797-S1-PL
02/05/2026
Permit issued — Structural
Q01280797-S2-ST
10/29/2025
Filed — Alteration
INSTALLATION AND REMOVAL OF PLUMBING FIXTURES IN THE EXISTING 2-FAMILY HOUSE.
Q01280797-S2
10/24/2025
Special inspection requirement — Final
YUNHO LEE
10/24/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
INHWAN CHANG
10/09/2025
Violation issued (ECB, closed)
Construction
10/09/2025
Violation issued (ECB, closed)
Unknown
09/25/2025
Permit issued — General Construction
Q01280797-I1-GC
09/15/2025
Filed — Alteration
INSTALLATION AND REMOVAL OF PLUMBING FIXTURES IN THE EXISTING 2-FAMILY HOUSE.
Q01280797-S1
09/15/2025
Filed — Alteration
INSTALLATION AND REMOVAL OF PLUMBING FIXTURES IN THE EXISTING 2-FAMILY HOUSE.
Q01280797-I1
09/15/2025
Special inspection requirement — Interior lighting power
Hackjong Choi
09/15/2025
Special inspection requirement — Energy Code Compliance Inspections
Hackjong Choi
09/15/2025
Special inspection requirement — Fire-Resistance Rated Construction
Hackjong Choi
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedURBAN MOONSTER CON CORP03/04/2026
DOB NOWGeneral ConstructionPermit IssuedURBAN MOONSTER CON CORP03/04/2026
DOB NOWPlumbingSigned-offI DO PLUMBING & HTG INC02/23/2026
DOB NOWStructuralPermit IssuedURBAN MOONSTER CON CORP02/05/2026
DOB NOWGeneral ConstructionPermit IssuedURBAN MOONSTER CON CORP09/25/2025
1 project · most recent 03/24/2026
Gas Water/Sanitary
FiledStatusContractorScope
03/24/2026Signed-offI DO PLUMBING & HTG INCGas, Water/Sanitary
2 projects · most recent 11/04/2025
General Wiring Lighting
FiledStatusContractorScope
11/04/2025Permit IssuedY.S ELECTRICGeneral Wiring, Lighting
11/04/2025Permit IssuedY.S ELECTRICGeneral Wiring, Lighting
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
05/04/2026Pass-Final Curb Cut Non-Directive 14PassView ↗
04/16/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/16/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
04/03/2026Fire-Resistant Penetrations and JointsHackjong Choispecial
04/03/2026Energy Code Compliance InspectionsHackjong Choiprogress
04/03/2026HVAC-R and service water heating system controlsHackjong Choienergy_progress
04/03/2026HVAC-R and service water heating equipmentHackjong Choienergy_progress
04/03/2026HVAC-R and service water piping design and insulationHackjong Choienergy_progress
10/24/2025FinalYUNHO LEEprogress
10/24/2025Structural Stability – Alterations of existing buildingsINHWAN CHANGspecial
09/15/2025Interior lighting powerHackjong Choienergy_progress
09/15/2025Energy Code Compliance InspectionsHackjong Choiprogress
09/15/2025Fire-Resistance Rated ConstructionHackjong Choiprogress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/18/2026Q01280797-I1Request digital key ↗
08/18/2026Q01280797-S1Request digital key ↗
08/18/2026Q01280797-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature5
09/01/2026Q01280797-S1Open ↗
09/01/2026Q01280797-S1Open ↗
08/28/2026Q01280797-S2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/18/2026Q01280797-S2Open ↗
08/18/2026Q01280797-S1Open ↗
08/18/2026Q01280797-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q01280797-S1Open ↗
08/28/2026Q01280797-S2Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/18/2026Q01280797-P1Open ↗
08/18/2026Q01280797-S2Open ↗
08/18/2026Q01280797-I1Open ↗
Showing 3 of 4 on file for this type