| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/10/2023 | Signed-off | SUPER MAX CONSULTING INC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/23/2022 | Complete | BERGER QUALITY ELEC'L CON | — |
| 10/20/2021 | Complete | KINGS ELECTRIC CO., INC. | General Wiring |
| 04/25/2018 | Permit Issued | D.R.P. ELEC'L CONTRG INC | 1 meters |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/20/2021 | Permit Issued | CEDARS CONSTRUCTION CORP | Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/06/2021 | Permit Issued | CEDARS CONSTRUCTION CORP | Fence |
| Owner | Filings | Most Recent |
|---|---|---|
| CEDARS CONSTRUCTION | 1 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| SCAGLIONE ARCHITECTS | 7 | 07/10/2023 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| CEDARS CONSTRUCTION CORP | General Contractor | 27 | 07/08/2026 |
| GREGG NY PLUMBING, INC | Plumbing | 2 | 07/08/2026 |
| BERGER QUALITY ELEC'L CON | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ROGERS CALVANICO GROUP PL | 1324 | 2 | 09/20/2021 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | GREGG NY PLUMBING, INC | 07/20/2022 |
| DOB NOW | General Construction | Permit Issued | CEDARS CONSTRUCTION GROUP | 01/19/2022 |
| DOB NOW | Foundation | Permit Issued | CEDARS CONSTRUCTION GROUP | 01/13/2022 |
| DOB NOW | General Construction | Permit Issued | CEDARS CONSTRUCTION GROUP | 01/13/2022 |
| DOB NOW | Foundation | Permit Issued | CEDARS CONSTRUCTION GROUP | 01/13/2022 |
| DOB NOW | Structural | Permit Issued | CEDARS CONSTRUCTION GROUP | 01/13/2022 |
| DOB NOW | Structural | Permit Issued | CEDARS CONSTRUCTION GROUP | 01/13/2022 |
| DOB NOW | Plumbing | Signed-off | GREGG NY PLUMBING, INC | 10/21/2021 |
| DOB NOW | Foundation | Permit Issued | CEDARS CONSTRUCTION GROUP | 10/20/2021 |
| DOB NOW | Structural | Permit Issued | CEDARS CONSTRUCTION GROUP | 10/19/2021 |
| DOB NOW | Structural | Permit Issued | CEDARS CONSTRUCTION GROUP | 10/19/2021 |
| DOB NOW | Earth Work | Permit Issued | CEDARS CONSTRUCTION GROUP | 10/19/2021 |
| DOB NOW | Construction Fence | Permit Issued | CEDARS CONSTRUCTION GROUP | 08/27/2021 |
| BIS | OT | ISSUED | SUNPOWER CORPORATION, SYS | 08/03/2022 |
| Date | Type | Result | Report |
|---|---|---|---|
| 06/16/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/30/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 07/28/2022 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 05/31/2022 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 04/05/2022 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 03/23/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 03/23/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 01/03/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 01/03/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 12/06/2021 | Energy Code Compliance Inspections | Richard Dailey | progress |
| 12/06/2021 | Permanent certificate | Richard Dailey | energy_progress |
| 12/06/2021 | HVAC-R and service water heating equipment | Richard Dailey | energy_progress |
| 12/06/2021 | HVAC-R and service water heating system controls | Richard Dailey | energy_progress |
| 12/06/2021 | Maintenance information | Richard Dailey | energy_progress |
| 12/06/2021 | HVAC-R and service water piping design and insulation | Richard Dailey | energy_progress |
| 10/05/2021 | Fire-Resistant Penetrations and Joints | Richard Dailey | special |
| 10/05/2021 | Structural Stability – Alterations of existing buildings | Richard Dailey | special |
| 10/05/2021 | Wood – Prefabricated I-Joists | Richard Dailey | special |
| 10/05/2021 | Subgrade Inspections | Richard Dailey | special |
| 10/05/2021 | Concrete - Cast-In-Place | Richard Dailey | special |
| 10/05/2021 | Fire-Resistance Rated Construction | Richard Dailey | progress |
| 10/05/2021 | Footing and Foundation | Richard Dailey | progress |
| 10/05/2021 | Structural Wood Frame | Richard Dailey | progress |
| 10/05/2021 | Energy Code Compliance Inspections | Richard Dailey | progress |
| 10/05/2021 | Final | Richard Dailey | progress |
| 10/05/2021 | Air barrier - visual inspection | Richard Dailey | energy_progress |
| 10/05/2021 | Insulation placement and R values | Richard Dailey | energy_progress |
| 10/05/2021 | Fenestration areas | Richard Dailey | energy_progress |
| 10/05/2021 | Permanent certificate | Richard Dailey | energy_progress |
| 10/05/2021 | Lighting in dwelling units | Richard Dailey | energy_progress |
| 10/05/2021 | Fenestration and door U-factor and product ratings | Richard Dailey | energy_progress |
| 10/05/2021 | Fenestration air leakage | Richard Dailey | energy_progress |
| 09/20/2021 | Energy Code Compliance Inspections | Richard Dailey | progress |
| 09/20/2021 | Fire-Resistance Rated Construction | Richard Dailey | progress |